HP P212/256 Raid Firmware Update

   Á¶È¸ 20884   Ãßõ 0    

페이지

다운로드

실행모드 변경
chmod u+x CP017907.scexe

실행
./
CP017907.scexe

Reboot

 hpacucli ctrl slot=1 show

Smart Array P212 in Slot 1
   Bus Interface: PCI
   Slot: 1
   Serial Number: PACCPID11490DXW
   Cache Serial Number: PACCQID12110RGV
   RAID 6 (ADG) Status: Disabled
   Controller Status: OK
   Chassis Slot:
   Hardware Revision: Rev C
   Firmware Version: 5.70
   Rebuild Priority: Medium
   Expand Priority: Medium
   Surface Scan Delay: 15 secs
   Surface Scan Mode: Idle
   Queue Depth: Automatic
   Monitor and Performance Delay: 60 min
   Elevator Sort: Enabled
   Degraded Performance Optimization: Disabled
   Inconsistency Repair Policy: Disabled
   Wait for Cache Room: Disabled
   Surface Analysis Inconsistency Notification: Disabled
   Post Prompt Timeout: 0 secs
   Cache Board Present: True
   Cache Status: OK
   Accelerator Ratio: 25% Read / 75% Write
   Drive Write Cache: Disabled
   Total Cache Size: 256 MB
   No-Battery Write Cache: Enabled
   Battery/Capacitor Count: 0
   SATA NCQ Supported: True

- to be continue -
±è¼º±Ç 2013-05
°¨»çÇÕ´Ï´Ù ..´öºÐ¿¡ ¿Â¶óÀο¡¼­ À߿ö󰩴ϴ٠..


Á¦¸ñPage 14/55
2014-05   4575340   Á¤ÀºÁØ1
2015-12   1124031   ¹é¸Þ°¡
2013-10   20996   Çà¾Æ¹ü
2015-01   12049   À±´ö°æ
2015-09   70597   Win31
2015-12   12665   justin1
2013-01   20885   ȸ¿øK
2014-06   79502   Å×µ¹¾ÆÀÌ
2015-01   11811   À±´ö°æ
2020-11   5334   D0111
2021-08   3382   ȸ»ó2
2013-02   20987   ȸ¿øK
2014-01   57496   ½ÃÇ»¸Ç
2015-01   11788   À±´ö°æ
2016-03   16041   PiPPuuP
2017-11   11204   ¸®µë¾Ø¹öÅÍ
2013-02   22092   ȸ¿øK
2015-01   49479   Àϸ®ÄÉ
2015-09   38264   HoneyJun
2018-04   8031   ÀÚ¿ïÀÚ¿ï
2022-01   46   motorod
2013-02   41129   ȸ¿øK