HP Smart Array P212 Æß¿þ¾î ¹× driver ¾÷µ¥ÀÌÆ®

   Á¶È¸ 21607   Ãßõ 0    

http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareIndex.jsp?la¡¦ (633)

2월 19일자로 펌웨어 및 드라이버 업데이트 되었내요..
아마도 Smart Array 제품군 모두 업데이트 되었을겁니다..
모두 업데이트 해보아요~

아참 저는 윈도우 서버 2012 사용중입니다. 다른 OS는 업데이트되었는지 모르겠내요.


펌웨어는 6.00 으로 업데이트 됐습니다..1월 중순에 5.70(b)로 업뎃했는데 한번 성능향상이 있나 봐야겠내요..

¸Å´ÏÁö¸ÕÆ® ¼ÒÇÁÆ®¿þ¾îµµ ¾÷±×·¹À̵åµÆ³»¿ä...
ȸ¿øK 2013-03
Problems Fixed:
The following problems are addressed in version 6.00 of Online ROM Flash Component for Linux - Smart Array P212, P410, P410i, P411, P711m, P712m, and P812:

On rare occasions during power-up of an HP DS2200sb the expander backplane would be unresponsive. When the expander backplane was unresponsive, the attached Smart Array Controller was not allowed to discover drives that were attached.
On an HP P812 controller, executing several sequential Write operations to more than 75 hard drives would result in a controller lockup.
Modified the FBWC module code to improve the training of the DDR2 DIMMs in order to prevent the rare occasions when 1783 POST error messages displays followed by an unresponsive controller.
Protection has been added to prevent potential Smart Array controller hangs under rare conditions when hot-adding hard drives.
When running in a Solaris environment, Smart Array firmware version 6.00 works around an issue where the driver would not handle asynchronous events from the Smart Array controller properly.
An interaction issue occurred between the Smart Array Controller and HP SAS Expander card in which the Hard Drives attached to the HP SAS Expander were not being discovered occasionally upon boot up or hot plug.
On rare occasions, the Smart Array controller would reset the same SATA drive several times when a PHY is stuck longer than four seconds.
The Smart Array P711m and P712m would report false link errors.
The Open Connection timeout was reduced to 900 microseconds so that SAS connections terminate gracefully and data transfer stalls are prevented.
The Smart Array controller would not connect to hard drives within 20ms under heavy stress.
Upon power up, a Post message will now be displayed to the user to indicate that a cache module is needed for the P711m controller.
When running heavy I/O in RAID 5, while an HP P410 controller was connected to more than 17 SAS drives in an HP DL180 G6 server with a 25SFF backplane, a lockup issue (error code 0xAB or 0xEA) could occur.
During heavy I/O when the HP P711m controller is connected to a HP P2000sa G3 MSA Array System via a HP 6Gb SAS Switch, a lockup issue (error code 0x15) could occur.
After a system with (2) or more empty SAS storage boxes, Box 1, 2, 3 ¡¦, attached to an HP SAS Expander card is powered up and then a drive is hot plugged into Box 2 or above, ACU and ORCA would incorrectly display the drive in Box 1.
ÁøÂ¥ ¹«½ÄÇÑ Áú¹®Àä P410À» »ç¿ëÇÏ°í ÀÖ½À´Ï´Ù..

Æß¿þ¾î ¾÷±×·¹À̵带 ¾î¶»°Ô Çؾߵdzª¿ä?? ÀоîºÁµµ ÀÌÇØ°¡ À߾ȵdz׿ä...


Á¦¸ñPage 32/55
2014-05   4483042   Á¤ÀºÁØ1
2015-12   1035104   ¹é¸Þ°¡
2013-03   21608   ÇÏÀÌ¿£µå
2013-07   22107   cjsrbc
2013-10   56269   ȲȥÀ»ÇâÇØ
2018-12   6314   chotws
2015-12   17328   thisway
2023-12   7930   ºÀ»ïÀÌ2
2014-07   49614   ȲȥÀ»ÇâÇØ
2013-07   31292   ȸ¿øK
2015-09   47882   Chrome
2018-05   16819   ±èÁÖÇö
2019-08   7453   ÁغñµÈ¹é¼ö
2022-08   16741   ³ª¶ó»ç¶û
2014-02   22707   cjsrbc
2015-06   13634   ±ø´Ù±¸
2018-12   7474   ¼Û½ÂÈ­
2020-05   4850   Á¦°Ô¶ó
2022-03   5721   ¿Ã´Ð½º
2013-07   28074   ±è¼öȯ¹«
2020-12   5679   Rainwalk
2022-03   5165   Ãʺ¸·¹À̵å