[re] Promise FastTrak SX4000 Áú¹®ÀÔ´Ï´Ù.

½É±Ô»ó   
   Á¶È¸ 13479   Ãßõ 3    

³×..

ÇÏÀÌÅÚ OSC Å×½ºÆ® ·¦¿¡¼­ Å×½ºÆ®ÇÑ ³»¿ëÀÌ ÀÖ¾î ¿Ã¸³´Ï´Ù.

Á¶±Ý ¾Æ½¬¿î ³»¿ëÀÔ´Ï´Ù¸¸...

Âü°í»ï¾Æ º¸½Ã±â ¹Ù¶ø´Ï´Ù.

±×·³..

P.S ¿©´ãÀÔ´Ï´Ù¸¸..

º¥Ä¡¸¶Å©ÇÑ °á°úº¸´Ù... »ç¿ë±â¸¦ ¿ì¼±ÀûÀ¸·Î º¸½Ã±æ ±ÇÇص帳´Ï´Ù.

ȣȯ¼ºÀÌ·¡µç°¡ ¾ÈÁ¤¼ºÀÌ·¡µç°¡..

¼º´Éº¸´Ù´Â ¾ÈÁ¤¼ºÀÌ ¿ì¼±ÀÌ°ÚÁö¿ä. °Å±â´Ù ¼º´É±îÁö ÁÁÀ¸¸é ´ÙÈ«Ä¡¸¶±¸¿ä..

------------------------------------------------------------------------------


 Á¦  ¸ñ:[OSC-LAB] ATA 4ä³Î RAID5Áö¿ø, FastTrak SX4000   [48718]
 º¸³½ÀÌ:OSµ¿È£È¸(k2osc2  )  2003-01-02 17:35  Á¶È¸:574

##. 4ä³Î RAID5 Áö¿ø RAID Ä«µå FastTrak SX4000

   ---------------------------------------------------------
   ÀÛ  ¼º      :   OSC labs Å×½ºÆ®ÆÀ
   Å×½ºÅÍ      :   ÀåÁØÈ£(4cbbs   )
   Á¤  ¸®      :   À̵¿ÁØ(ldjok   )
   ±â  °£      :   2002.12.05 - 2002.12.27
   Á¦  Ç°      :   FastTrak SX4000
   Á¦Á¶¿ø      :   Promise Technology Inc.
                   (http://www.promise.com)
   ÆǸſø      :   ·¹À̵åÄÄ
                   (0**-****-****, ´ã´çÀÚ ±èÁ¤È¯´Ô)
   ---------------------------------------------------------

1. ¼­¹®

XT ½ÃÀýºÎÅÍ I/O °ü·Ã Á¦Ç°À¸·Î À¯¸íÇß´ø Promise »ç¿¡¼­ ±âÁ¸ÀÇ Àú°¡Çü
RAID¿¡¼± ã¾Æº¼ ¼ö ¾ø¾ú´ø RAID5 Áö¿ø°ú Cache žÀç µî °­·ÂÇÑ ±â´ÉÀ»
°¡Áø ¾ß½ÉÂù ATA RAID Á¦Ç°À» Ãâ½ÃÇß´Ù. À̸§Àº FastTrak SX4000.

ÀÌ¿¡ Æò¼Ò FTP ¼­¹ö ¿î¿µ¿¡ °ü½ÉÀÌ ¸¹°í, Áý¿¡¼­ SCSI RAID ¸¦ ¾²¸ç ÃÖ±Ù
¿ë·® °í¹Î¿¡ ºüÁ®ÀÖ´ø ÇÊÀÚ°¡ ¼±¶æ ÀÌ Á¦Ç°ÀÇ Å×½ºÆ®¸¦ ÀÚûÇÏ°Ô µÇ¾ú´Ù.

 * RAID(Redundant Array of Inexpensive Disks)¶õ?

¸î ³âÀü¸¸ Çصµ ´ë¿ë·®ÀÇ ÆÄÀÏ ¼­¹ö, ¿÷½ºÅ×À̼ǿ¡¼­³ª »ç¿ëÇß´ø ´ë¿ë·®ÀÇ
µ¥ÀÌÅ͸¦ °í¼ÓÀ¸·Î Àü¼Û °¡´ÉÇÏ°Ô ÇØÁÖ´Â ±â¼úÀÌ´Ù. ÃÖ±Ù Çϵåµð½ºÅ©¿Í
ÄÁÆ®·Ñ·¯ ±â¼úÀÇ ¹ß´Þ ¹× °¡°ÝÀÇ Àú·ÅÈ­·Î ÀÏ¹Ý PC¿¡¼­µµ RAID¸¦ ±¸ÃàÇØ
È°¿ëÇÏ´Â ¿¹°¡ ¸¹¾ÆÁö°í ÀÖ´Ù.

RAID ¿¡ ´ëÇØ ´õ ÀÚ¼¼È÷ ¾Ë°í ½ÍÀº ºÐµéÀº ¾Æ·¡ URL À» ÂüÁ¶Çϱ⠹ٶõ´Ù.
http://www.kbench.com/hardware/print.jsp?no=10123

2. Á¦Ç° »ç¾ç ¹× ³»¿ë¹°

 *. Á¦Ç°»ç¾ç

    Á¦Ç°¸í : FastTrak SX4000
    Á¦Á¶»ç : Promise (http://www.promise.com)
    Áö¿øµå¶óÀ̺ê : 4ä³Î, 4µå¶óÀ̺ê(ä³Î´ç 1µå¶óÀ̺ê)
    Áö¿ø RAID Level : 0/1/5/1+0
    PCI Bus Support : 66MHz or 33MHz, 64bit/32bit PCI 2.1/2.2 support
    ACPI Support : S1, S3 & S4
    Cache Memory : ÃÖ¼Ò 64MB,
                   ÃÖ´ë 256MBÀÇ ECC or
                        Non ECC Unbuffered 168pin PC100 or PC133 SDRAM
    Áö¿ø ¿î¿µÃ¼Á¦ : Windows XP/2000/NT, Redhat Linux 7.2/7.3,
                    Suse Linux 7.3/8.0, Turbo Server 6.5 Workstation 7.0
    Management : Promis Array Management S/W

 *. ³»¿ë¹°

    FastTrak SX4000 ÄÁÆ®·Ñ·¯ Ä«µå
    ¿ä¾à »ç¿ë ¼³¸í¼­
    OS µå¶óÀ̹ö µð½ºÄÏ(Windows XP/2000/NT¿ë µå¶óÀ̹ö¸¸ µé¾îÀÖ´Ù)
    18ÀÎÄ¡ Ultra ATA, 80wire/40pin ³»Àå ÇÏµå µð½ºÅ© ÄÉÀ̺í 4°³
    YŸÀÔ ÆÄ¿ö ½ºÇø´ ÄÉÀ̺í 2°³

3. Å×½ºÆ® ½Ã½ºÅÛ ¹× ¼ÒÇÁÆ®¿þ¾î

 *. Å×½ºÆ® ½Ã½ºÅÛ

    CPU : Intel Pentium 4 1.3GHz (FSB : 400MHz (4x100MHz))
    Motherboard : Intel D850GB (BIOS v.P18)
    /Chipset : Intel i850 (OnBoard IDE Pri/Sec ¸ðµÎ ATA100 Áö¿ø)
    /North Bridge : Intel 82850
    /South Brigde : Intel 82801BA
    Memory Size : 256MB (64MBx4, RAMBUS DRAM PC800)
    Graphics : GeForce2 MX400 64MB (BIOS v.3.11.01.2622)
    ===================================================================
    Storage :

    1 IBM IC35L073UWD210-0 73GB U160 10K RPM SCSI HDD (4MB ¹öÆÛ)
    -> Adaptec 29160 Ultra160 SCSI ÄÁÆ®·Ñ·¯¿¡ ¿¬°á
  
    1 Maxtor 98196H8 80GB 5400RPM ATA100 (2MB ¹öÆÛ, NTFS, ±âº» µð½ºÅ©)
    -> M/B (Pri Master) ¿¡ ¿¬°á

    1 Maxtor 98196H8 80GB 5400RPM ATA100 (2MB ¹öÆÛ, NTFS, µ¿Àû µð½ºÅ©)
    -> M/B (Sec Master) ¿¡ ¿¬°á
    
    4 Maxtor 98196H8 80GB 5400RPM ATA100 -> FastTrak SX4000
    ===================================================================
    SCSI : Adaptec 29160 Ultra160 SCSI (BIOS v.2.57.2)
    RAID : Promise FastTrak SX4000 (BIOS v.1.01.0.1)
    RAID Cache Memory : Unbuffered 168pin PC100 SDRAM 64MB(Çö´ë)
                        PC133 64MB/128MB/256MB(»ï¼º)  
    Power Supply : Bestec ATX-250-12V / Bestec ATX-1956F B


 *. º¥Ä¡¸¶Å© ÇÁ·Î±×·¥ ¹× ¼ÒÇÁÆ®¿þ¾î ¼³Á¤
    
    Operating System : ÇÑ±Û Windows 2000 Server SP3
    Graphics Driver : nVIDIA Detonator v.41.09
    Chipset Driver : Intel v.4.10.1012
    IDE Driver : Intel Application Accelerator v.2.30
    SCSI Driver : Adaptec 29160 Ultra160 SCSI Driver v.6.1.530.201
    RAID Driver : Promise FastTrak SX4000 Windows Driver v.1.01.0.16
                  (µð½ºÄÏ¿£ v1.01.0.15 ¹öÀüÀÌ µé¾îÀÖ´Ù)
    RAID S/W : Promise Array Manager v.3.01.0.45
    Benchmark S/W : SisSoftware Sandra2002 Pro (v.2002.1.8.59)
                    Rundegren QuickBench (v.1.1)
                    hdtach (v.2.61)

4. Á¦Ç°ÀÇ ¼³Ä¡

¼³Ä¡´Â ±²ÀåÈ÷ ½¬¿ü´Ù. ¿©Å¸ È®Àå Ä«µåµé°ú ¸¶Âù°¡Áö·Î ¿ì¼± RAID ÄÁÆ®·Ñ·¯¸¦
PCI ½½·Ô¿¡ ²È°í, Çϵå¿Í ÄÉÀ̺íµéÀ» ¿¬°áÇÑ µÚ ÄÄÇ»Å͸¦ ÄÒ´Ù. ÀÌÈÄ \'Ctrl+F\'
Å°¸¦ ´­·¯ FastTrak ¼Â¾÷ È­¸éÀ¸·Î ÁøÀÔ, RAID Array ¸¦ ¼³Á¤ÇÑ´Ù. ±×¸®°í ½Ã½ºÅÛÀ»
ºÎÆýÃÄÑ »õ Çϵå¿þ¾î ¹ß°ß ¸Þ½ÃÁö°¡ ³ª¿À¸é µå¶óÀ̹ö¸¦ ¼³Ä¡ÇÑ µÚ
\'ÄÄÇ»ÅÍ °ü¸® - µð½ºÅ© °ü¸®\'¿¡¼­ ÆÄƼ¼Ç »õ·Î Àâ¾ÆÁÖ°í Æ÷¸ËÇÑ ÈÄ »ç¿ëÇÏ¸é µÈ´Ù.

Âü°í·Î Array¸¦ ÀâÀ» ¶§ ÁÖÀÇÇÒ Á¡À» À̾߱âÇÏÀÚ¸é, µð½ºÅ©¸¦ Ãß°¡ÇÒ ¶§´Â
¹Ýµå½Ã ±×¸¸Å­ÀÇ Swap ¿ë µð½ºÅ©¸¦ ¸ÕÀú ÇÒ´çÇØÁà¾ß ÇÑ´Ù. ¸Þ¸ð¸® ¿ë·®Àº
ÀûÀ¸¸é¼­ ¿ø·¡ ÇϵåÀÇ 3-4¹è Å©±â¿¡ ´ÞÇÏ´Â array¸¦ Àâ¾Æ µð½ºÅ©·Î ÀνĽÃÅ°¸é
swap ¸Þ¸ð¸® ºÎÁ· ¿¡·¯°¡ ³ª¿À¸é¼­ °è¼Ó ¹«ÇÑ ·çÇÁ¸¦ µµ´Â À©µµ2000ÀÇ ¹ö±×¿¡
Á÷¸éÇÏ
°Ô µÈ´Ù.

µû¶ó¼­ array¸¦ Àâ±â Àü¿¡´Â ÃæºÐÈ÷ (ÃÖ¼ÒÇÑ 1GB ÀÌ»ó) Å« ¿ë·®ÀÇ Swap ¿ë
µð½ºÅ©¸¦ ¹Ýµå½Ã ÇÒ´çÇØ ³õ±â ¹Ù¶õ´Ù.

5. Å×½ºÆ®

 *. º¥Ä¡¸¶Å© 1

°¢°¢ 5ȸ¾¿ º¥Ä¡¸¶Å·À» ÇØ Á¦ÀÏ ÁÁÀº Á¡¼ö¸¦ ±â·ÏÇß´Ù.

º¥Ä¡¸¶Å©´Â ¾îµð±îÁö³ª ÂüÁ¶¿ëÀÏ»Ó, ½ÇÁ¦ »ç¿ë½Ã ´À²¸Áö´Â ¼º´É°ú´Â ¾öû³ª°Ô
´Ù¸¦ ¼ö ÀÖ´Ù´Â Á¡À» À¯³äÇØµÎ°í °á°ú¸¦ º¸±â ¹Ù¶õ´Ù. ¶ÇÇÑ °¢ º¥Ä¡¸¶Å© S/W ¸¶´Ù
ÃøÁ¤¹æ¹ýµéÀÌ ´Ù¸£±â ¶§¹®¿¡ ¾û¶×ÇÑ °á°ú¸¦ ³»³õÀ» °¡´É¼ºµµ ³ô´Ù´Â Á¡µµ
À¯ÀÇÇØ¾ß ÇÑ´Ù.

º¥Ä¡¸¶Å© °á°ú¿¡¼­ ½Ã°£Àº ªÀ» ¼ö·Ï, CPU Á¡À¯À²Àº ³·À» ¼ö·Ï,
Àü¼Û·®Àº Ŭ ¼ö·Ï ÁÁ´Ù.

<< IBM SCSI HDD -> 29160 ¿¡ ¿¬°á>>
* SisSoftware Sandra2002 Pro
- Drive Index : 25789
- Buffered read : 90MB/s
- Sequential Read : 36MB/s
- Random Read : 10MB/s
- Buffered write : 10MB/s
- Sequential write : 32MB/s
- Random Write : 14MB/s
- Avg access time : 5ms

* Rundegren QuickBench
- Sequential Read : 52.10MB/s
- Sequential Write : 38.93MB/s
- CPU Á¡À¯À² : 3%
- Random Access Read Speed
  Size Time     Speed
  512B 6.85ms / 72.99KB/s
  1KB  6.93ms / 144.30KB/s
  2KB  6.71ms / 298.06KB/s
  4KB  7.05ms / 567.38KB/s
  8KB  6.77ms / 1.15MB/s
  16KB 6.87ms / 2.27MB/s
  32KB 7.23ms / 4.32MB/s
  64KB 7.99ms / 7.82MB/s
  128KB 9.31ms / 13.42MB/s
  256KB 12.02ms / 20.81MB/s
  512KB 16.99ms / 29.44MB/s
  1MB 26.92ms / 37.15MB/s
  2MB 47.29ms / 42.49MB/s
  4MB 88.59ms / 45.15MB/s
  8MB 168.68ms / 47.43MB/s
  16MB 331.68ms / 48.24MB/s

ÀÌ »õ·Î¿î S/W º¥Ä¡¸¶Å© Å×½ºÆ®¿¡¼­ Ãִ븦 16MB ·Î Å×½ºÆ® ÇÑ °ÍÀº
Å×½ºÆ® ½Ã°£À» ´ÜÃàÇϱâ À§ÇÔÀ̱⵵ ÇÏÁö¸¸, ÀÎÅͳݿ¡¼­ ÀÚ·á ±³È¯ÀÇ
°æ¿ì ¸¹Àº °æ¿ì¿¡ ÀÖ¾î 15MB ·Î Àß¶ó¼­ ºÐÇÒ¾ÐÃàÀ» ÇÏ´Â °æ¿ì°¡ ¸¹±â ¶§¹®À̾ú´Ù.

* HDtach (Advanced Size Check OFF)
- Random Access Time : 8.6ms
- Read Speed : Max 57MB/s  Min 7MB/s  Avg 43MB/s
- CPU Á¡À¯À² : 12.7%

IBM SCSI Çϵ忡 OS ¹× º¥Ä¡¸¶Å· S/W ¸¦ ¼³Ä¡ÇØ Å×½ºÆ®ÇÑ °á°úÀÌ´Ù.
Non OS ÇÏµå »óÅ·ΠÅ×½ºÆ® Çß´õ¶ó¸é ´õ ÁÁÀº ¼º´ÉÀ» º¸¿©ÁáÀ» °ÍÀ¸·Î È®½ÅÇÑ´Ù.

<< Maxtor 80GB HDD -> M/B ¿¡ Ultra ATA100 À¸·Î ¿¬°á>>
* SisSoftware Sandra2002 Pro
- Drive Index : 18528 (13621)
- Buffered read : 81MB/s (82MB/s)
- Sequential Read : 26MB/s (19MB/s)
- Random Read : 5MB/s (3.8MB/s)
- Buffered write : 54MB/s (56MB/s)
- Sequential write : 26MB/s (20MB/s)
- Random Write : 9MB/s (6MB/s)
- Avg access time : 10ms

* Rundegren QuickBench
- Sequential Read : 26.95MB/s (27.19MB/s)
- Sequential Write : 26.68MB/s (23.98MB/s)
- CPU Á¡À¯À² : 2% (1%)
- Random Access Read Speed
  Size Time      Speed
  512B 17.02ms / 29.37KB/s   (17.34 / 28.83)
  1KB  16.58ms / 60.30KB/s   (16.69 / 59.92)
  2KB  16.48ms / 121.33KB/s  (16.88 / 118.51)
  4KB  18.51ms / 216.15KB/s  (18.63 / 214.75)
  8KB  17.97ms / 445.29KB/s  (18.50 / 432.43)
  16KB 18.35ms / 872.12KB/s  (18.38 / 870.70)
  32KB 18.95ms / 1.65MB/s    (19.09 / 1.64)
  64KB 20.99ms / 2.98MB/s    (21.31 / 2.93)
  128KB 23.59ms / 5.30MB/s   (24.19 / 5.17)
  256KB 28.34ms / 8.82MB/s   (28.25 / 8.85)
  512KB 38.81ms / 13.22MB/s  (38.56 / 12.97)
  1MB 56.60ms / 17.67MB/s    (57.22 / 17.48)
  2MB 94.06ms / 21.26MB/s    (94.91 / 21.07)
  4MB 168.38ms / 23.76MB/s   (170.63 / 23.44)
  8MB 318.22ms / 25.14MB/s   (322.59 / 24.80)
  16MB 622.70ms / 25.69MB/s  (629.72 / 25.41)

°ýÈ£¾ÈÀÇ ¼öÄ¡´Â D850GB º¸µå¿¡¼­ ¾Æ´äÅØ29160 SCSIÄÁÆ®·Ñ·¯¿Í FastTrak SX4000À»
µÑ ´Ù ÀåÂøÇßÀ» ¶§ µÑ ÁßÀÇ Çϳª°¡ ÀâÈ÷Áú ¾Ê¾Æ ÇÏ´Â ¼ö ¾øÀÌ 80GB Çϵ忡 OS¿Í
º¥Ä¡¸¶Å© S/W, µå¶óÀ̹öµî Å×½ºÆ® ȯ°æÀ» »õ·Î ±¸ÃàÇؼ­ ´Ù½Ã Çѹø Å×½ºÆ®¸¦ ÇÑ
°ÍÀÌ´Ù.

* HDtach (Advanced Size Check OFF)
- Random Access Time : 21.2ms (23.1ms)
- Read Speed : Max 30MB/s  Min 3MB/s  Avg 24MB/s
- CPU Á¡À¯À² : 11.7% (9.1%)

<< 3 Maxtor 80GB HDD -> SX4000 RAID0 ·Î ±¸¼º (PC100 64MB cache) >>

* SisSoftware Sandra2002 Pro
- Drive Index : 27917
- Buffered read : 103MB/s
- Sequential Read : 34MB/s
- Random Read : 3.9MB/s
- Buffered write : 31MB/s
- Sequential write : 67MB/s
- Random Write : 18MB/s
- Avg access time : 14ms

* Rundegren QuickBench
- Sequential Read : 31.93MB/s
- Sequential Write : 75.30MB/s
- CPU Á¡À¯À² : 3%
- Random Access Read Speed
  Size Time      Speed
  512B 18.06ms / 27.68KB/s  
  1KB  18.87ms / 52.98KB/s
  2KB  24.00ms / 83.33KB/s
  4KB  19.59ms / 204.14KB/s
  8KB  22.09ms / 362.09KB/s
  16KB 21.91ms / 730.39KB/s
  32KB 29.56ms / 1.06MB/s
  64KB 31.22ms / 2.00MB/s
  128KB 56.78ms / 2.20MB/s
  256KB 67.25ms / 3.72MB/s
  512KB 72.75ms / 6.87MB/s
  1MB 89.56ms / 11.17MB/s
  2MB 141.97ms / 14.09MB/s
  4MB 200.16ms / 19.98MB/s
  8MB 340.28ms / 23.51MB/s
  16MB 645.22ms / 24.80MB/s

* HDtach (Advanced Size Check OFF)
- Random Access Time : 21.2ms (23.1ms)
- Read Speed : Max 32MB/s  Min 0.5MB/s  Avg 18MB/s
- CPU Á¡À¯À² : 0.0%

<< 3 Maxtor 80GB HDD -> SX4000 RAID0 ·Î ±¸¼º (PC133 64MB cache) >>

* SisSoftware Sandra2002 Pro
- Drive Index : 26732
- Buffered read : 103MB/s
- Sequential Read : 32MB/s
- Random Read : 3.8MB/s
- Buffered write : 30MB/s
- Sequential write : 68MB/s
- Random Write : 15MB/s
- Avg access time : 15ms

* Rundegren QuickBench
- Sequential Read : 31.91MB/s
- Sequential Write : 75.28MB/s
- CPU Á¡À¯À² : 3%
- Random Access Read Speed
  Size Time      Speed
  512B 18.05ms / 27.69KB/s  
  1KB  18.88ms / 52.95KB/s
  2KB  23.99ms / 83.35KB/s
  4KB  19.58ms / 204.16KB/s
  8KB  22.10ms / 362.10KB/s
  16KB 21.90ms / 730.17KB/s
  32KB 29.54ms / 1.04MB/s
  64KB 31.23ms / 2.00MB/s
  128KB 56.79ms / 2.21MB/s
  256KB 67.24ms / 3.72MB/s
  512KB 72.76ms / 6.88MB/s
  1MB 89.55ms / 11.16MB/s
  2MB 141.98ms / 14.10MB/s
  4MB 200.15ms / 19.97MB/s
  8MB 340.26ms / 23.50MB/s
  16MB 645.20ms / 24.81MB/s

* HDtach (Advanced Size Check OFF)
- Random Access Time : 22.4ms (23.1ms)
- Read Speed : Max 31MB/s  Min 1.2MB/s  Avg 18MB/s
- CPU Á¡À¯À² : 0.0%

<< 3 Maxtor 80GB HDD -> SX4000 RAID0 ·Î ±¸¼º (PC133 128MB cache) >>

* SisSoftware Sandra2002 Pro
- Drive Index : 27024
- Buffered read : 103MB/s
- Sequential Read : 38MB/s
- Random Read : 3.9MB/s
- Buffered write : 31MB/s
- Sequential write : 46MB/s
- Random Write : 19MB/s
- Avg access time : 15ms

* Rundegren QuickBench
- Sequential Read : 31.85MB/s
- Sequential Write : 75.31MB/s
- CPU Á¡À¯À² : 3%
- Random Access Read Speed
  Size Time      Speed
  512B 17.66ms / 28.32KB/s  
  1KB  18.91ms / 52.89KB/s
  2KB  20.00ms / 100.33KB/s
  4KB  21.84ms / 193.65KB/s
  8KB  22.28ms / 366.23KB/s
  16KB 22.28ms / 718.07KB/s
  32KB 25.97ms / 1.20MB/s
  64KB 27.56ms / 2.27MB/s
  128KB 55.34ms / 2.26MB/s
  256KB 58.06ms / 4.31MB/s
  512KB 72.31ms / 6.91MB/s
  1MB 85.91ms / 11.64MB/s
  2MB 130.25ms / 15.36MB/s
  4MB 198.09ms / 20.19MB/s
  8MB 341.98ms / 23.39MB/s
  16MB 621.37ms / 25.75MB/s

* HDtach (Advanced Size Check OFF)
- Random Access Time : 22.7ms
- Read Speed : Max 31MB/s  Min 0.5MB/s  Avg 18MB/s
- CPU Á¡À¯À² : 6.0%

<< 3 Maxtor 80GB HDD -> SX4000 RAID0 ·Î ±¸¼º (PC133 256MB cache) >>

* SisSoftware Sandra2002 Pro
- Drive Index : 27047
- Buffered read : 103MB/s
- Sequential Read : 33MB/s
- Random Read : 4MB/s
- Buffered write : 33MB/s
- Sequential write : 65MB/s
- Random Write : 17MB/s
- Avg access time : 12ms

* Rundegren QuickBench
- Sequential Read : 31.82MB/s
- Sequential Write : 75.30MB/s
- CPU Á¡À¯À² : 5%
- Random Access Read Speed
  Size Time      Speed
  512B 17.69ms / 28.27KB/s  
  1KB  17.91ms / 55.85KB/s
  2KB  20.44ms / 97.87KB/s
  4KB  20.44ms / 195.71KB/s
  8KB  21.84ms / 366.23KB/s
  16KB 25.94ms / 616.90KB/s
  32KB 24.81ms / 1.26MB/s
  64KB 26.16ms / 2.39MB/s
  128KB 53.31ms / 2.34MB/s
  256KB 62.53ms / 4.00MB/s
  512KB 73.75ms / 6.78MB/s
  1MB 92.25ms / 10.84MB/s
  2MB 127.59ms / 15.67MB/s
  4MB 201.56ms / 19.84MB/s
  8MB 337.34ms / 23.71MB/s
  16MB 606.44ms / 26.38MB/s

* HDtach (Advanced Size Check OFF)
- Random Access Time : 22.5ms
- Read Speed : Max 34MB/s  Min 0.5MB/s  Avg 18MB/s
- CPU Á¡À¯À² : 5.9%

<< 4 Maxtor 80GB HDD -> SX4000 RAID0 ·Î ±¸¼º (PC133 256MB cache) >>

* SisSoftware Sandra2002 Pro
- Drive Index : 32867
- Buffered read : 102MB/s
- Sequential Read : 42MB/s
- Random Read : 5MB/s
- Buffered write : 78MB/s
- Sequential write : 70MB/s
- Random Write : 25MB/s
- Avg access time : 11ms

* Rundegren QuickBench
- Sequential Read : 54.77MB/s
- Sequential Write : 76.50MB/s
- CPU Á¡À¯À² : 3%
- Random Access Read Speed
  Size Time      Speed
  512B 17.31ms / 28.88KB/s  
  1KB  17.66ms / 56.64KB/s
  2KB  18.72ms / 106.85KB/s
  4KB  18.34ms / 218.05KB/s
  8KB  21.09ms / 379.29KB/s
  16KB 18.84ms / 849.08KB/s
  32KB 24.59ms / 1.27MB/s
  64KB 23.47ms / 2.66MB/s
  128KB 48.66ms / 2.57MB/s
  256KB 73.28ms / 3.41MB/s
  512KB 86.47ms / 5.78MB/s
  1MB 97.13ms / 10.30MB/s
  2MB 132.56ms / 15.09MB/s
  4MB 195.63ms / 20.45MB/s
  8MB 292.22ms / 27.38MB/s
  16MB 517.13ms / 30.94MB/s

* HDtach (Advanced Size Check OFF)
- Random Access Time : 23.1ms
- Read Speed : Max 29MB/s  Min 1.0MB/s  Avg 16MB/s
- CPU Á¡À¯À² :  5.8%

<< 3 Maxtor 80GB HDD -> SX4000 RAID5 ·Î ±¸¼º (PC133 256MB cache) >>

* SisSoftware Sandra2002 Pro
- Drive Index : 14454
- Buffered read : 103MB/s
- Sequential Read : 20MB/s
- Random Read : 3.9MB/s
- Buffered write : 17MB/s
- Sequential write : 18MB/s
- Random Write : 3.5MB/s
- Avg access time : 13ms

* Rundegren QuickBench
ÇÁ·Î±×·¥Àº ½ÇÇàµÇ³ª, ¹«½¼ ÀÌÀ¯¿¡¼­ÀÎÁö error3 À̶ó°í ³ª¿À°ï º¥Ä¡¸¶Å© ¾ÈµÊ

* HDtach (Advanced Size Check OFF)
- Random Access Time : 22.4ms
- Read Speed : Max 28MB/s  Min 0.9MB/s  Avg 11MB/s
- CPU Á¡À¯À² :  5.8%

*. º¥Ä¡¸¶Å© 2

º¥Ä¡¸¶Å©2´Â ÀÚ·á°¡ ²Ë Âù µ¿Àû µð½ºÅ© º¼·ýÀÇ Maxtor 80GB ¸¦ Sec Master¿¡
¿¬°áÇÑ ÈÄ °¢ µð½ºÅ©·Î µ¥ÀÌÅ͸¦ º¹»çÇÒ ¶§ °É¸° ½Ã°£À» ÃøÁ¤Çß´Ù.

Cache´Â ¹Ù·Î Àü¿¡ ÀÐÀº µ¥ÀÌÅ͸¦ ´Ù½Ã ÀÐ°Ô µÉ °æ¿ì¿¡ Á¦ÀÏ È®½ÇÇÑ È¿°ú°¡
³ªÅ¸³ª±â ¶§¹®¿¡ °°Àº Å×½ºÆ®¸¦ SX4000 ¿¡¼­ ¼¼¹ø¾¿ ¿¬¼ÓÇؼ­ Å×½ºÆ®ÇÏ°í
¼¼¹ø° °á°ú¸¦ ±â·ÏÇß´Ù.

* 717MB avi ÆÄÀÏ 1°³ º¹»ç½Ã ¼Ò¿ä½Ã°£
Pri Master 80GB -> Pri Master 80GB : 1ºÐ 1ÃÊ
Pri Master 80GB -> 4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 128MB cache)) : 32ÃÊ
Pri Master 80GB -> 4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 256MB cache)) : 28ÃÊ
Pri Master 80GB -> 3 Maxtor 80GB HDD(SX4000 RAID5 (PC133 256MB cache)) : 30ÃÊ
Sec Master 80GB -> Pri Master 80GB : 6ºÐ 38ÃÊ
Sec Master 80GB -> 4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 128MB cache)) : 10ºÐ
3
1ÃÊ
Sec Master 80GB -> 4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 256MB cache)) : 7ºÐ
21
ÃÊ
Sec Master 80GB -> 3 Maxtor 80GB HDD(SX4000 RAID5 (PC133 256MB cache)) : 4ºÐ 6
ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 128MB cache)) -> Pri Master : 37ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 256MB cache)) -> Pri Master : 36ÃÊ
3 Maxtor 80GB HDD(SX4000 RAID5 (PC133 256MB cache)) -> Pri Master : 38ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 128MB cache)) -> Sec Master : 30ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 256MB cache)) -> Sec Master : 23ÃÊ
3 Maxtor 80GB HDD(SX4000 RAID5 (PC133 256MB cache)) -> Sec Master : 59ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 128MB cache)) -> 4 Maxtor 80GB
HDD(SX4000
 RAID0 (PC133 128MB cache)) : 28ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 256MB cache)) -> 4 Maxtor 80GB
HDD(SX4000
 RAID0 (PC133 256MB cache)) : 19ÃÊ
3 Maxtor 80GB HDD(SX4000 RAID5 (PC133 256MB cache)) -> 3 Maxtor 80GB
HDD(SX4000
 RAID5 (PC133 256MB cache)) : 49ÃÊ

* 358MB 1°³ Æú´õ(28°³ ÆÄÀÏ)  º¹»ç½Ã ¼Ò¿ä½Ã°£
Pri Master 80GB -> Pri Master 80GB : 40ÃÊ
Pri Master 80GB -> 4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 128MB cache)) : 16ÃÊ
Pri Master 80GB -> 4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 256MB cache)) : 13ÃÊ
Pri Master 80GB -> 3 Maxtor 80GB HDD(SX4000 RAID5 (PC133 256MB cache)) : 16ÃÊ
Sec Master 80GB -> Pri Master 80GB : 10ºÐ 23ÃÊ
Sec Master 80GB -> 4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 128MB cache)) : 1ºÐ
26
ÃÊ
Sec Master 80GB -> 4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 256MB cache)) : 1ºÐ
19
ÃÊ
Sec Master 80GB -> 3 Maxtor 80GB HDD(SX4000 RAID5 (PC133 256MB cache)) : 56ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 128MB cache)) -> Pri Master : 20ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 256MB cache)) -> Pri Master : 16ÃÊ
3 Maxtor 80GB HDD(SX4000 RAID5 (PC133 256MB cache)) -> Pri Master : 18ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 128MB cache)) -> Sec Master : 15ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 256MB cache)) -> Sec Master : 15ÃÊ
3 Maxtor 80GB HDD(SX4000 RAID5 (PC133 256MB cache)) -> Sec Master : 17ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 128MB cache)) -> 4 Maxtor 80GB
HDD(SX4000
 RAID0 (PC133 128MB cache)) : 15ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 256MB cache)) -> 4 Maxtor 80GB
HDD(SX4000
 RAID0 (PC133 256MB cache)) : 12ÃÊ
3 Maxtor 80GB HDD(SX4000 RAID5 (PC133 256MB cache)) -> 3 Maxtor 80GB
HDD(SX4000
 RAID5 (PC133 256MB cache)) : 28ÃÊ

* 180MB 1°³ Æú´õ (461°³ ÆÄÀÏ) º¹»ç½Ã ¼Ò¿ä½Ã°£
Pri Master 80GB -> Pri Master 80GB : 31ÃÊ
Pri Master 80GB -> 4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 128MB cache)) : 17ÃÊ
Pri Master 80GB -> 4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 256MB cache)) : 15ÃÊ
Pri Master 80GB -> 3 Maxtor 80GB HDD(SX4000 RAID5 (PC133 256MB cache)) : 25ÃÊ
Sec Master 80GB -> Pri Master 80GB : 44ÃÊ
Sec Master 80GB -> 4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 128MB cache)) : 65ÃÊ
Sec Master 80GB -> 4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 256MB cache)) : 34ÃÊ
Sec Master 80GB -> 3 Maxtor 80GB HDD(SX4000 RAID5 (PC133 256MB cache)) : 65ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 128MB cache)) -> Pri Master : 18ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 256MB cache)) -> Pri Master : 15ÃÊ
3 Maxtor 80GB HDD(SX4000 RAID5 (PC133 256MB cache)) -> Pri Master : 18ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 128MB cache)) -> Sec Master : 33ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 256MB cache)) -> Sec Master : 26ÃÊ
3 Maxtor 80GB HDD(SX4000 RAID5 (PC133 256MB cache)) -> Sec Master : 26ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 128MB cache)) -> 4 Maxtor 80GB
HDD(SX4000
 RAID0 (PC133 128MB cache)) : 14ÃÊ
4 Maxtor 80GB HDD(SX4000 RAID0 (PC133 256MB cache)) -> 4 Maxtor 80GB
HDD(SX4000
 RAID0 (PC133 256MB cache)) : 14ÃÊ
3 Maxtor 80GB HDD(SX4000 RAID5 (PC133 256MB cache)) -> 3 Maxtor 80GB
HDD(SX4000
 RAID5 (PC133 256MB cache)) : 31ÃÊ

6. º¥Ä¡¸¶Å© °á°ú ¿ä¾à

 *. Cache Memory Å©±â, ¼Óµµ¿¡ µû¸¥ ¼º´É Â÷ÀÌ

º¥Ä¡¸¶Å©1ÀÇ °á°ú¿¡¼± Cache ÀÇ ¿ë·®À̳ª ¼Óµµ°¡ ´Þ¶óµµ ±×¸® Å« °á°ú Â÷ÀÌ´Â
º¸¿©ÁÖÁö ¾Ê¾Ò´Ù. ÇÏÁö¸¸ Access Time Àº ¾à°£À̳ª¸¶ °¨¼ÒÇÏ´Â Ãß¼¼ÀÓÀ» ¾Ë ¼ö
ÀÖ°í, Àü¼Û·®µµ ¼ÒÆøÀ̳ª¸¶ Áõ°¡Ãß¼¼ÀÓÀ» ¾Ë ¼ö ÀÖ´Ù. ¸Þ¸ð¸® °ªµµ ½Ñµ¥ °¡´ÉÇϸé
PC133 256MB¸¦ ´Þµµ·Ï ÇÏÀÚ.

 *. Cache Memory Å©±â¿¡ µû¸¥ ÆÄÀÏ º¹»ç½Ã ¼Ò¿ä½Ã°£ ºñ±³

º¥Ä¡¸¶Å©1ÀÇ °á°ú¿Í´Â ´Þ¸® Cache ÀÇ ¿ë·® Â÷ÀÌ¿¡ µû¶ó ½Ã°£ÀÇ Áõ°¨ÀÌ ³ªÅ¸³ª´Â °É
¾Ë ¼ö ÀÖ´Ù. ¿ª½Ã CPU °Ç Disk °Ç Cache ´Â Å©°í ºÁ¾ß ÇÑ´Ù.

 *. RAID vs Non RAID

¸¶´õº¸µåÀÇ ATA100¿¡ ¿¬°áÇÑ °°Àº HDD ¿ÍÀÇ ¼º´Éºñ±³¿¡ ÀÖ¾î Random Read/Write¿¡¼±
¸¹Àº Â÷ÀÌ°¡ ¾ø¾úÁö¸¸, Sequential Read / Write ¿¡¼± È®½ÇÇÑ ¼º´É Â÷À̸¦ º¸¿©ÁÖ°í
ÀÖ´Ù. ¶ÇÇÑ Array ³»ºÎ¿¡¼­ÀÇ ÆÄÀÏ º¹»ç½Ã¿£ ȯ»óÀûÀÎ Â÷À̸¦ º¸¿©ÁÖ°í ÀÖ´Ù.

ÀÌ·± Á¡µé¿¡¼­ RAID ÀÇ Àǹ̸¦ ãÀ» ¼ö ÀÖ°Ú´Ù ÇÏ°Ú´Ù. Å« ¿ë·®ÀÇ ÆÄÀϵéÀ» ¸¹ÀÌ
»ç¿ëÇÑ´Ù¸é 4°³ÀÇ Çϵ带 À常ÇØ RAID0 ·Î ±¸¼ºÇÏ°í 256MB Cache ¸¦ ÀåÂøÇØ
»ç¿ëÇÑ´Ù¸é ÁÁÀº È¿°ú¸¦ ¾òÀ» ¼ö ÀÖÀ» °ÍÀÌ´Ù.

 *. RAID0 ¿¡¼­ ÇÏµå ¼ö Áõ°¡¿¡ µû¸¥ ¼º´É Â÷ÀÌ

RAID0 ¸¦ ÀÌÇØÇÏ°í ÀÖ´Â µ¶ÀÚ¶ó¸é ´ç¿¬ÇÑ ¾Ë°í ÀÖ´Â ¾ê±â°ÚÁö¸¸, À§ °á°ú¿¡¼­ º¼
¼ö ÀÖµíÀÌ »ó´çÇÑ ¼º´ÉÀÇ Â÷À̸¦ ¾òÀ» ¼ö ÀÖ´Ù. RAID0 ·Î ²Ù¹Ð °èȹÀ̶ó¸é °¡´ÉÇÑ
¸¹Àº ¼öÀÇ Çϵ带 ´ÞÀÚ.

 *. RAID0¿Í RAID5 ¿¡¼­ÀÇ ¼º´É Â÷ÀÌ

RAID ÀÇ °³³ä¿¡¼­ ºÃÀ» ¶© ¿ª½Ã RAID0 °¡ 5º¸´Ü ÈξÀ ¼º´ÉÀÌ ÁÁ´Ù. RAID5 °¡
RAID0¿Í 1ÀÇ ÀåÁ¡¸¸À» Á¶ÇÕÇÑ °ÍÀ̶õ °ÍÀ» »ý°¢ÇØ º¸¸é ´ç¿¬ÇÑ °á°ú´Ù.
Å×½ºÆ® °á°úµµ ¿¹Ãø´ë·Î RAID0 °¡ ´õ ÁÁÀº ¼º´ÉÀ» º¸¿©ÁáÀ¸³ª, RAID5µµ
±×·°Àú·° ±¦ÂúÀº ¼º´ÉÀ» º¸¿©Áá´Ù.

 *. RAID Array ÀÇ ¾ÈÁ¤¼º

ÇÊÀÚ¿Í ¿©·¯ FTP ¼­¹ö ¿î¿µÀÚµéÀÌ À̱¸µ¿¼ºÀ¸·Î Çß´ø ¾ê±âÁö¸¸, IDE RAID ´Â
SCSI RAID ¿¡ ºñÇØ Àß ±úÁø´Ù´Â Á¤¼³ÀÌ ÀÖ´Ù. Promise SX4000 ÀÇ °æ¿ì¿¡µµ
ÀÌ·± ¾ê±â´Â ¾î´À Á¤µµ Àû¿ëÀÌ °¡´ÉÇØ º¸ÀÌ´Â µí Çß´Ù. ½ÇÁ¦·Î ÇÊÀÚÀÇ ½Ã½ºÅÛ
¹®Á¦ÀÎÁö ´Ù¸¥ ¹®Á¦¶§¹®ÀÎÁö ¸ô¶óµµ ½Ã½ºÅÛÀ» Àç½ÃÀÛ ÇßÀ» ¶§ Array ±¸¼ºÀ»
ãÀ» ¼ö ¾ø´Ù´Â ¿¡·¯¸¦ ¿©·¯¹ø Á¢ÇÒ ¼ö ÀÖ´Ù. ¹°·Ð ´Ù½Ã ±âÁ¸ ±¸¼º ±×´ë·Î
Array ¸¦ ±¸¼ºÇßÀ» °æ¿ì µ¥ÀÌÅͳª »ç¿ë¿¡´Â ¹®Á¦°¡ ¾ø¾úÁö¸¸, ¸Å¿ì ¹ø°Å·Î¿ü´Ù.

´Ü, ÆÄ¿ö¸¦ Çϳª ´õ ´Þ¾Æ¼­ Çϵå 3°³¸¦ Ãß°¡ÇÑ ÆÄ¿ö¿¡ ¿¬°áÇÑ ÈÄ¿¡´Â ÀÌ·± ¹®Á¦°¡
¹ß»ýÇÏÁö ¾Ê¾Ò´Ù. Âü°í·Î Áý¿¡¼­ »ç¿ëÇÏ´Â SCSI RAID ´Â Array Çѹø ÀâÀº ÀÌÈÄ
2³â°£ ÀÌ·± ¹®Á¦¸¦ Çѹøµµ Á¢ÇÑ ÀûÀÌ ¾ø¾ú´Ù. ¹°·Ð SCSI Çϵå´Â 10K 2°³ ¹Û¿¡
¾È´Þ¾Ò°í, ÆÄ¿öµµ ¼¼ºìÆÀ 350W¸¦ ½á¼­ ³Ë³ËÇؼ­ ±×·± ¹®Á¦°¡ ¾ø¾ú´ÂÁöµµ ¸ð¸£°Ú´Ù.

7. ÃÑÆò

ÀÌ»óÀ¸·Î °£´ÜÇÏ°Ô Á¦Ç°¿¡ ´ëÇÑ Å×½ºÆ®¸¦ ÇØ º¸¾Ò´Ù.

ÀÌ Å×½ºÆ® ¸®Æ÷Æ®°¡ µ¶ÀÚ ¿©·¯ºÐÀÇ Á¦Ç° ¼±Åÿ¡ Á¶±ÝÀ̳ª¸¶ µµ¿òÀÌ µÈ´Ù¸é
±â»Ú°Ú´Ù. Á» ´õ ½ÅÇüÀÇ ºü¸£°í ÁÁÀº IDE Çϵ尡 ÀÖ¾ú´Ù¸é º¸´Ù ´õ ÁÁÀº
¼º´ÉÀ» º¸¿©ÁÖÁö ¾Ê¾ÒÀ»±î ÇÏ´Â »ý°¢ÀÌ µé¾ú´Ù. ´Ù¸¸, ´É·Â ºÎÁ· + °ÔÀ¸¸§À¸·Î
ÀÎÇØ º¸´Ù ½Éµµ ±íÀº Å×½ºÆ®¸¦ ÇØ º¸Áö ¸øÇÑ °ÍÀÌ Á˼۽º·¯¿ï »ÓÀÌ´Ù.
(Stripe Block Size ¿¡ µû¸¥ ¼º´É Â÷À̵µ Å×½ºÆ®Çغ¸°í ½Í¾úÁö¸¸...)

º» Á¦Ç°Àº Àú·ÅÇÑ ºñ¿ëÀ¸·Î Array ¸¦ ±¸¼ºÇؼ­ Á¶±ÝÀ̳ª¸¶ ½Ã½ºÅÛ ¼ÓµµÀÇ °¥ÁõÀ»
ÇؼÒÇÏ°í ½ÍÀº ÆÄ¿öÀ¯Àúµé¿¡°Ô ±ÇÇÏ°í ½ÍÀº Á¦Ç°ÀÌ´Ù. ¾Æ½Ã´Ù½ÃÇÇ, ÇöÀçÀÇ
ÄÄÇ»Æà ±â¼ú¿¡¼­ Á¦ÀÏ ¹ß¸ñÀ» Àâ´Â ºÎºÐÀÌ µð½ºÅ© ºÎºÐÀÌ´Ù. ÇÏ·ç »¡¸® µð½ºÅ©ÀÇ
¼Óµµ°¡ ¸Þ¸ð¸®ÀÇ ¼Óµµ¸¦ µû¶óÀâ´Â ³¯ÀÌ ¿À±æ ¹Ù¶ó¸é¼­ ¸®ºä¸¦ ¸¶Ä¡°íÀÚ ÇÑ´Ù.

Âü°í·Î ÀÌ Á¦Ç°¿¡ ´ëÇÑ º¸´Ù Àü¹®°¡ÀûÀÎ(?) »ó¼¼ÇÑ ¸®ºä ¹× 3Ware, Adaptec,
Highpoint µî °í°¡ ¹× Àú°¡Çü RAID Á¦Ç°°úÀÇ ºñ±³´Â ¾Æ·¡ URL¿¡¼­ ã¾Æº¼ ¼ö ÀÖ´Ù.
¿µ¹® ÆäÀÌÁöÁö¸¸, ±×·¡ÇÁ¸¸ ºÁµµ ´ëÃæÀº ¾Ë ¼ö ÀÖ´Ù.

http://www.tech-report.com/reviews/2002q4/ideraid/index.x?pg=1

 * ÀåÁ¡

1. °¡°ÝÀÌ Àú·ÅÇÏ´Ù.
2. ¼³Ä¡ ¹× °ü¸®°¡ ½±´Ù. ƯÈ÷, PAM ¿¡¼­ Áö¿øµÇ´Â ´ÙÁß email Å뺸³ª ¿¡·¯
   À¯Çüº°·Î report ÇÏ´Â ±â´ÉÀº ¼­¹ö °ü¸®Àڵ鿡°Õ ¸Å¿ì À¯¿ëÇÏ´Ù.
3. ºñ±³Àû ¾ÈÁ¤µÈ Array ¿î¿ëÀÌ °¡´ÉÇß´Ù. ÀϺη¯ RAID°¡ ±¸¼ºµÈ Çϵ带 È® »©¼­
   µ¥ÀÌÅÍ°¡ ¾î¶»°Ô µÇ³ª È®ÀÎÇϱ⵵ ÇÏ°í, ¾²±âÀÛ¾÷À» ÇÏ´Â µµÁß Àü¿øÀ» È®
   ²¨¹ö¸®±âµµ ÇßÀ¸³ª, ¿îÀÌ ÁÁ¾Ò´ÂÁö µÎ °æ¿ì ¸ðµÎ µ¥ÀÌÅÍ´Â ÀÌ»ó¾ø¾ú´Ù.
4. 3Ware, Adaptec µîÀÇ °æÀï Á¦Ç°°ú ºñ±³ÇØ º¼ ¶§ °¡°Ý´ë ¼º´Éºñ°¡ ¶Ù¾î³ª´Ù.

* ´ÜÁ¡

1. Cache ¸Þ¸ð¸®¸¦ º°µµ·Î ±¸ÀÔÇØ¾ß ÇÑ´Ù. 64MB ÀÌ»óÀÇ Cache ¸Þ¸ð¸® ÀåÂøÀ»
   ¾ÈÇϸé ÀÛµ¿À» ¾È ÇÑ´Ù.
2. Hot Swap Àº Promise SuperSwap Chassis ¸¦ ÀÌ¿ëÇÒ ¶§¸¸ Áö¿øµÈ´Ù.
3. Array °¡ ÀÚÁÖ ±úÁ®¼­ array ±¸¼ºÀ» ¹Ýº¹ ¼³Á¤ÇØÁà¾ß ÇÏ´Â °æ¿ì°¡ ¸¹´Ù.
   ÆÄ¿ö¸¦ µÎ°³·Î º¸°­ÇÑ ÀÌÈÄ ¹®Á¦°¡ ¾ø¾ú´Ù.
4. °¡²û¾¿ IRQ ¸¦ ÇÒ´çÇÒ ¼ö ¾ø´Ù, M/B°¡ PCI Bus Efficiency ¸¦ Áö¿øÇÏ´ÂÁö
   È®ÀÎÇ϶ó°í ³ª¿Â´Ù. ±×¶§¸¶´Ù ¸î¹ø¾¿ ²°´Ù ÄÑ¸é ¹®Á¦°¡ ¾ø¾îÁö°ï Çߴµ¥,
   PCI Ä«µå¶ó°í´Â RAID ÄÁÆ®·Ñ·¯ ´Þ¶û Çϳª ÀåÂøÇÑ ½Ã½ºÅÛ¿¡¼­ ¿Ö ÀÌ·±
   ¸Þ¼¼Áö°¡ ³ª¿À´ÂÁö ¾Ë ¼ö°¡ ¾ø¾ú´Ù.
5. Data Read ¶© UATA133 ÀÇ ¼Óµµ·Î ÀÛµ¿ÇÏÁö¸¸, Write ¶© UATA100 ÀÇ ¼Óµµ·Î
   ÀÛµ¿ÇÑ´Ù. ÇÏÁö¸¸, ´ëºÎºÐ UATA100 Çϵ带 »ç¿ëÇϱ⠶§¹®¿¡ Å« ´ÜÁ¡Àº
   ¾Æ´Ï¶ó°í »ý°¢µÈ´Ù.
6. CPU Á¡À¯À²ÀÌ »ó´ëÀûÀ¸·Î ³ô´Ù. »ç¿ëÀÚ ¼ö°¡ ÀûÀº ÆÄÀϼ­¹ö ³ª FTP¼­¹ö·Î
   »ç¿ë½Ã¿£ º° ¹®Á¦°¡ ¾ø°ÚÁö¸¸, 3D ·»´õ¸µÀ̳ª ¾Ö´Ï¸ÞÀ̼ǵîÀÇ ±×·¡ÇÈÀÛ¾÷
   µîÀ» ¸¹ÀÌ ÇÏ´Â °æ¿ì¿£ ¹®Á¦°¡ µÉ ¼ö ÀÖ´Ù.
7. ¸Å´º¾óÀÇ ±×¸²¿¡´Â ºê¶óÄϺκп¡ 4°³ÀÇ LED °¡ º¸À̳ª, Å×½ºÆ®ÇÑ Àåºñ¿¡´Â
   ¾ø¾ú´Ù. ¶ÇÇÑ ±âÆÇ¿¡ ¹èÅ͸®¸¦ ´Þ ¼ö ÀÖµµ·Ï µÇ¾îÀÖ´Â °Í °°Àºµ¥,
   ºñ¿ë¶§¹®ÀÎÁö ¾Æ´Ï¸é ´Ù¸¥ ¹®Á¦¶§¹®ÀÎÁö ¾Ë ¼ö´Â ¾øÁö¸¸, ´Þ·ÁÀÖÁö ¾Ê¾Ò´Ù.

ÁÖ) 5¹ø°ú 6¹øÀº Tech-report ¿¡¼­ ½½Â½(?)ÇÑ ³»¿ëÀÌ´Ù. 5¹øÀÇ °æ¿ì ÇÊÀÚÀÇ º¸µå¿Í
    Çϵå´Â ÇØ´ç»çÇ×ÀÌ ¾ø¾ú°í, 6¹øÀÇ °æ¿ì ¿ª½Ã ¹Ý´ëÀÇ °á°ú°¡ ³ª¿Ô´Ù.
    Å×½ºÆ® ȯ°æ°ú º¥Ä¡¸¶Å© S/WÀÇ Â÷À̶§¹®À̶ó°í ÀÌÇØÇÏ¸é µÇ°Ú´Ù.    


 ------------------------------------------------------------------------------

ªÀº±Û Àϼö·Ï ½ÅÁßÇÏ°Ô.


QnA
Á¦¸ñPage 4504/5589
2015-12   1030659   ¹é¸Þ°¡
2014-05   4478316   Á¤ÀºÁØ1
2006-10   4651   ¾ÈâÁØ
2006-10   4408   ÀåÁø¼ö
2006-10   4831   ¿ø³«¿¬
2006-10   4323   ¹ÎºÀ±â
2006-10   5633   ÃÖâÇö
2006-10   4919   ³ëÇϼ®
2006-10   4703   ¹®Ãß±â
2006-10   4747   ³ëÇϼ®
2006-10   4459   ÀÌÀç¼±
2006-10   5174   ÀÌÀç¼±
2006-10   4435   ÀÌÀç¼±
2006-10   4796   º¯Çؼ®
2006-10   4488   Á¤¸íÇö
2006-10   4735   ÀÌ°üÈ£
2006-10   4622   ¹ÎºÀ±â
2006-10   5269   ¹ÚÁ¤±æ
2006-10   5066   À±È£¿ë
2006-10   4514   ¹ÎºÀ±â
2006-10   5000   ¼ÛÀçÈÆ
2006-10   4162   ±è´ë¼º