[VMWare] VMware ESXi 6.7 Update 3 Release

행아범   
   조회 6134   추천 0    

https://docs.vmware.com/en/VMware-vSphere/6.7/rn/vsphere-esxi-67u3-re… (1000)

 What's New

  • ixgben driver enhancements: The ixgben driver adds queue pairing to optimize CPU efficiency.
  • VMXNET3 enhancements: ESXi 6.7 Update 3 adds guest encapsulation offload and UDP, and ESP RSS support to the Enhanced Networking Stack (ENS). Checksum calculations are offloaded from encapsulated packets to the virtual device emulation and you can run RSS on UDP and ESP packets on demand. UDP RSS supports both IPv4 and IPv6, while ESP RSS supports only IPv4. The feature requires a corresponding VMXNET3 v4 driver.
  • NVIDIA virtual GPU (vGPU) enhancements: With vCenter Server 6.7 Update 3, you can configure virtual machines and templates with up to four vGPU devices to cover use cases requiring multiple GPU accelerators attached to a virtual machine. To use the vMotion vGPU feature, you must set the vgpu.hotmigrate.enabled advanced setting to true and make sure that both your vCenter Server and ESXi hosts are running vSphere 6.7 Update 3.
    vMotion of multi GPU-accelerated virtual machines might fail gracefully under heavy GPU workload due to the maximum switch over time of 100 secs. To avoid this failure, either increase the maximum allowable switch over time or wait until the virtual machine is performing a less intensive GPU workload.
  • bnxtnet driver enhancements: ESXi 6.7 Update 3 adds support for Broadcom 100G Network Adapters and multi-RSS feed to the bnxtnet driver.
  • QuickBoot support enhancements: ESXi 6.7 Update 3 whitelists Dell EMC vSAN Ready Nodes servers R740XD and R640 for QuickBoot support.
  • Configurable shutdown time for the sfcbd service: With ESXi 6.7 Update 3, you can configure the shutdown time of the sfcbd service. You can set a shutdown time depending on the third-party CIM provider that you use, or else use the default setting of 10 sec.



검은콩 2019-08
Broadcom 100G Network Adapters 가 눈에 들어오네요 ㄷ;
     
epowergate 2019-08
아직은 대세는 아닌것 같은데 최근 모 고객사에서 VMWARE Pool 만드는데 서버 16대가 100G, 나머지 60대가 25G 였습니다.
세상이 또 한번 빠뀌고 있는것 같습니다.
포우 2019-08
업데이트 후에 Page allocation error와 함께 장기 대기 타다 리부트만 시키는 현상 다수 보고 되고 있습니다 저도 겪었고요. 주의하세요.
     
포우 2019-08
동일 증상 있는 분은 UEFI 쓰지 말고 레거시 온리 부트로 해보셔요.
pass 2019-09
전 버그 픽스가 참 좋내요 ㅠㅠ




제목Page 5/61
2019-12   1923   히소카
2019-11   1531   송주환
2019-11   1318   송주환
2019-11   1909   ckpal
2019-11   1414   서광희
2019-11   1217   ioscanknfc
2019-11   1976   ioscanknfc
2019-11   2576   통화중입니닷
2019-11   2442   jhoon24
2019-11   2933   하이바
2019-10   2496   철이님
2019-10   2767   yzzeee
2019-10   3051   소푸
2019-10   5283   준비된백수
2019-10   6504   그림일기
2019-09   4561   송주환
2019-09   7523   아맞다내우산
2019-08   7485   빠시온
2019-08   6135   행아범
2019-08   6763   chotws