[VMWare] Configuring VMDirectPath I/O pass-through devices on an ESX/ESXi host

   Á¶È¸ 14534   Ãßõ 1    

http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=1010789

To configure pass-through devices on an ESX host:
  1. Select an ESX host from the Inventory of VMware vSphere Client.

    Note: If you have a chipset with VT-d, when you click Advanced Settings in vSphere Client, you can select the devices that are dedicated to the VMDirectPath I/O.

  2. In the Configuration tab, click Advanced SettingsThe Pass-through Configuration page lists all available pass-through devices.

    Note
    A green icon indicates that a device is enabled and active. An orange icon indicates that the state of the device has changed and the host must be rebooted before the device can be used.

  3. Click Edit.
  4. Select the devices and click OK.
  5. When the devices are selected, they are marked with an orange icon. Reboot for the change to take effect. After rebooting, the devices are marked with a green icon and are enabled.

    Note: The configuration changes are saved in the /etc/vmware/esx.conf file. The parent PCI bridge, and if two devices are under the same PCI bridge, only one entry is recorded. 

    The PCI slot number where the device was connected is 00:0b:0. It is recorded as:

    /device/000:11.0/owner = "passthru"

    Note:
     11 is the decimal equivalent of the hexadecimal
     0b.

    To configure a PCI device on a virtual machine:
  1. From the Inventory in vSphere Client, right-click the virtual machine and choose Edit Settings.
  2. Click the Hardware tab.
  3. Click Add.
  4. Choose the PCI Device.
  5. Click Next.

참조. 

ESXi as a Desktop with VMDirectPath I/O

- to be continue -
ÃÖÀçÈÆ 2013-06
vt-D ±â´ÉÀÇ °æ¿ì ±ØÈ÷ ÀϺΠµð¹ÙÀ̽º¸¸ Áö¿øÇϸç vSphereÀÇ ´ë´Ù¼ö Ư¡µéÀ» »ç¿ëÇÒ ¼ö ¾ø½À´Ï´Ù.
Ưº°ÇÑ °æ¿ì¸¦ Á¦¿ÜÇÏ°í´Â °ÅÀÇ »ç¿ëÇÏÁö ¾Ê½À´Ï´Ù.
     
¼ºÈÆ 2013-06
Àúµµ °øºÎÁßÀÎ ³»¿ëÀ̶ó Áú¹®µå·Áµµ µÉ±î¿ä?

vt-D´Â ´ëºÎºÐ(i½Ã¸®Áî ÀÌÈÄÀÇ..)ÀÇ Á¦¿Â¿¡¼­ Áö¿øÇÏ´Â °Í °°°í, ¸ÞÀκ¸µå»ó¿¡¼­ vt-d¸¸ Áö¿øÇÏ¸é ¸ðµÎ »ç¿ë °¡´ÉÇÏÁö ¾Ê³ª¿ä? ±ØÈ÷ ÀϺΠµð¹ÙÀ̽º¸¸ Áö¿øÇÑ´Ù¶ó´Â Àǹ̸¦ Àß ¸ð¸£°Ú½À´Ï´Ù....

vSphereÀÇ ´ë´Ù¼ö Ư¡À» »ç¿ëÇÒ ¼ö ¾ø´Ù°í Çϼ̴µ¥, passthrough¸¦ Çϱâ À§Çؼ­ vt-d±â´ÉÀ» »ç¿ëÇÏ¸é ¾î¶² ±â´ÉµéÀ» »ç¿ëÇÒ ¼ö ¾ø°Ô µÇ´ÂÁö ±Ã±ÝÇÕ´Ï´Ù.
          
ÃÖÀçÈÆ 2013-06
BIOS¿¡¼­ Áö¿øÀ» Çصµ Processor ¶ÇÇÑ È®ÀÎÀÌ ÇÊ¿äÇÒ °æ¿ì°¡ ÀÖ½À´Ï´Ù.
´ë´Ù¼öÀÇ »ç¿ëÇÒ ¼ö ¾ø´Â Ư¡Àº VM ¼³Á¤ ½Ã passthrough device¸¦ Ãß°¡ÇϽô °æ¿ì
Memory reservationÀÌ VM¿¡ ÇÒ´çÇÑ ÃÖ´ë¿ë·®À¸·Î °íÁ¤µÇ¾î ¹ö¸³´Ï´Ù.
Áï vSphere Memory balloon, swap, share ¸ðµÎ »ç¿ëÀÌ ºÒ°¡´ÉÇÏ°í
¿ª½Ã Snapshot, Clone, vMotion µî ´ëºÎºÐÀÇ ±â´ÉÀ» »ç¿ëÇÒ ¼ö ¾ø½À´Ï´Ù.

°ø½ÄÀûÀ¸·Î Áö¿øµÇ´Â ¸ñ·ÏÀº ¸Þ´º¾óÀ» º¸½Ã¸é ¾Æ½Ã°ÚÁö¸¸ ±ØÈ÷ ÀϺÎÀÇ NIC, SAS HBA¸¸ Áö¿øÇÕ´Ï´Ù.
¹®Á¦´Â ÇØ´ç deviceÀÇ firmware¿¡ ±²ÀåÈ÷ ¹Î°¨ÇÏ¸ç °¡»óÈ­ÀÇ ÀåÁ¡ÀÌ ¸¹ÀÌ Åð»öµË´Ï´Ù.

All In One ¹æ½ÄÀÇ VSA °°Àº °æ¿ì¿¡´Â ´ÜÀÏ VM¸¸À» ±¸µ¿ÇϹǷΠ¿¹¿ÜÀÔ´Ï´Ù.


Á¦¸ñPage 84/127
2015-12   1026375   ¹é¸Þ°¡
2014-05   4473300   Á¤ÀºÁØ1
2016-02   7389   chotws
2016-02   6145   ĵÀ§µå
2016-02   15261   ĵÀ§µå
2016-02   6479   ĵÀ§µå
2016-02   6657   yootopia
2016-02   6311   yexxnoah
2016-02   6075   Àü¼³¼ÓÀǹ̡¦
2016-02   12136   ±ô¹Ú±ô¹Ú°¡
2016-02   6905   yexxnoah
2016-02   4265   Àü¼³¼ÓÀǹ̡¦
2016-02   6814   ggg345
2016-02   6281   ÄĹÚ
2016-01   7259   ¸éºÀ
2016-01   6168   ggg345
2016-02   4300   ggg345
2016-01   6524   ÁÒ¯
2016-01   6605   ½Å¿ì¼·
2016-01   5212   SaNoRaMyun
2016-01   8502   ºêÀÌ¿¥¿þ¾î
2016-01   7291   chotws