ÀÌ¹Ì cµå¶óÀ̺꿡 OS¼³Ä¡µÇ¾î ÀÖÀ» ¶§ raid 1·Î ¹­À¸·Á¸é?

Q±º   
   Á¶È¸ 29681   Ãßõ 0    

¾È³çÇϼ¼¿ä?

µ¨ 720¿¡ µ¿ÀÏÇÑ HDD°¡ µÎ°³ ´Þ·Á ÀÖ½À´Ï´Ù.
¿ø·¡ °èȹÀº Cµå¶óÀ̺ê Dµå¶óÀÌºê ³ª´²¼­ ¾²·Á°í raid·Î ¹­Áö ¾Ê°í windows server 2012¸¦ ¼³Ä¡Çß½À´Ï´Ù.

Áö±ÝÀº °èȹÀÌ ¹Ù²î¾î¼­ HDD µÎ°³¸¦ raid 1·Î ¹­°í ½ÍÀºµ¥¿ä. OS¸¦ ´Ù½Ã ¼³Ä¡ÇÏÁö ¾Ê°í ¹­À» ¼ö ÀÖÀ»±î¿ä?
¸»Â¯È² 2014-03
¾ø½À´Ï´Ù....
     
±è±ÔÁø 2014-03
¿Í¿ì ª°í ¸íÈ®ÇÑ ´äº¯ °¨»çÇÕ´Ï´Ù
AKAÁö´Ï 2014-03
Æ®·çÀ̹ÌÁö ±â¾÷¿ë¹öÀü¿¡¼­´Â ·¹À̵å Áö¿øÇÕ´Ï´Ù ½Ì±Û ¹é¾÷ÈÄ ·¹ÀÌµå ¹­°í º¹±¸,,,
Ȩ¿¡µð¼Ç¿¡¼­´Â ·¹À̵å Áö¿øÇÏÁö ¾Ê½À´Ï´Ù
     
±è±ÔÁø 2014-03
¾ÆÅ©·Î´Ï½º ¼­¹ö ¹öÀüÀÌ Àִµ¥ °°Àº ±â´ÉÀÌ ÀÖ´ÂÁö È®ÀÎÇغÁ¾ß°Ú³×¿ä..
°¨»çÇÕ´Ï´Ù^^
          
AKAÁö´Ï 2014-03
Universal Restore ¾Öµå¿ÂÀÌ ÀÖÀ¸¼Å¾ßÇÒ²®´Ï´Ù
¸»Â¯È² 2014-03
°£´ÜÇÏ°Ô ÇÒ¼ö´Â ¾øÁö¸¸¿ä.
ºÎÆ®À̹ÌÁö¸¦ ´Ù¸¥ Çϵ忡 º¹»çÇÏ½Ã°í ·¹À̵å1 Àâ°í °Å±â´Ù ´Ù½Ã Ç®¸é µË´Ï´Ù¸¸...

±×º¸´Ù »õ·Î ¼³Ä¡ Çϴ°ÍÀÌ ´õ ³ºÀ»¼öµµ ÀÖ½À´Ï´Ù...
VINCENT 2014-04
¿äÁò SSD ¸¹ÀÌ ½Ñµ¥ ÀÛÀº °Å Çϳª ±¸Çϼż­ °Å±â´Ù OS ´Ù½Ã ±ò°í ÇÏµå µÎ°³¸¦ ´Ù ¾²½Ã´Â °Ô ³´Áö ¾ÊÀ»±î¿ä?
¾Æ¹«·¡µµ OS¶õ ³ðÀº ±×´Ú Áß¿äÇÑ °Íµµ ¾Æ´Ñ °ÍÀÌ ¹®Á¦ »ý±â¸é ½Ã½ºÅÛ¿¡ Á¢±ÙÀÌ ¾Æ¾ê ¾ÈµÇ´Ï º°µµ·Î ¾²½Ã´Â°Ô...
¾Æ, ±Ùµ¥, µ¨720¿¡ SSD ´Þ ¼ö ¾ø³ª.... ÇÏ°í ã¾Æº¸´Ï Àֳ׿ä.
·¹À̵å 1ÀÌ¸é µÎ Çϵ带 ¹Ì·¯ÇØ¾ß ÇÒÅÙµ¥ ¿À¿¡½º±îÁö ¹Ì·¯ÇÏ´Â °Ç È¿À²ÀûÀÏ °Í °°Áö ¾Ê³×¿ä.
SSD°¡ »¡¶ó¾ß ÇÒ ÇÊ¿ä ¾øÀ¸´Ï±î ±¸Çü ȤÀº Áß°íµµ ±¦ÂúÀ» µí Çϳ׿ä.
½ÉÁö¾î USBµµ ±¦ÂúÀ» µí....
Àü¿¡ HP ¸¶ÀÌÅ©·Î ¼­¹ö ¾µ ¶§ USB µÎ°³ »ç¼­ °Å±â¿¡´Ù OS µÎ°³ ¼³Ä¡ÇØ ³õ±¸ ¼³Á¤µµ ¶È°°ÀÌ ÇØ ³õ±¸ Çϳª´Â ¿î¿ëÇÏ´Â µ¥, Çϳª´Â ÀÀ±Þ ¿ëÀ¸·Î Áغñ ÇØ ³õ°í ¾´ ÀûÀÌ Àֳ׿ä.
¹º ÀÏ »ý±â¸é ¹Ù·Î ¹Ù²ã ²¸¼­ °è¼Ó ÀÛµ¿½ÃÄ״µ¥, ÀÏ³â ³Ñ°Ô ¾µÀÏÀÌ ¾È »ý±â´õ±º¿ä.
ȸ¿øK 2014-04
°¡´ÉÀº Çѵ¥, ½ÇÁ¦·Î Çغ¸Áö´Â ¾Ê¾Ò½À´Ï´Ù.
LSI MegaRaid ¸Å´º¾óÀ» º¸¸é 1°³ÀÇ disk (raid 0)¿¡¼­ 2°³ÀÇ disk(raid 1) °¡´ÉÇÏ´Ù°í µÇ¾î ÀÖ½À´Ï´Ù.

Follow these steps to migrate the RAID level:
Caution: Back up any data that you want to keep before you change the RAID level of the virtual disk.
1. On the main WebBIOS CU screen, select a virtual disk.
2. Click Virtual Disks.
3. When the Virtual Disk screen appears, select Migration only (and skip to step 6) or Migration with addition in the right panel.
4. If you selected Migration with addition, select one or more physica disks from the small window in the lower right of the screen.
5. Select a new RAID level from the drop-down menu on the right. The available RAID levels are limited, based on the current RAID level of the virtual disk plus the number of physical disks available.
6. When you have made your selections, click Go at the bottom of the right panel.
7. When the message appears, confirm that you want to migrate the RAID level of the virtual disk.
A reconstruction operation begins on the virtual disk. You must wait until the reconstruction is completed before performing any other tasks in the WebBIOS CU.
ÀÌ·Ð»ó °¡´ÉÇÕ´Ï´Ù.
ÀÚü ·¹À̵å Áö¿øÇÏ´Â ¿ÜÀåÇϵ忡 ±×·± ±â´ÉÀÌ ÀÖ´Â Á¦Ç°ÀÌ ÀÖ½À´Ï´Ù.
µ¥ÀÌÅÍ°¡ µé¾îÀÖ´Â Çϵå 2°³ ²È°í, ·¹À̵å0 ¼³Á¤Çϸé, ±âÁ¸ µ¥ÀÌÅÍ ¿µ¿ªÀ» Á¦¿ÜÇÑ ³ª¸ÓÁö ºÎºÐ¿¡ ¾²±â¸¦ ½ÃÀÛÇÑ´Ù°í ÇÕ´Ï´Ù.
Áï, ±×°ÍÀ» ºÐ¸®ÇÏ¸é ·¹À̵尡 Ç®¸®Áö¸¸(2°³ÀÇ ÇϵåÀÇ µ¥ÀÌÅÍ°¡ ´Ù ³¯¾Æ°¡´Ï Àý´ë ÇÏÁö ¸» °Í), ±× ÀÚü·Î´Â óÀ½ºÎÅÍ ·¹À̵å0 ¼³Á¤ÇÑ °Íó·³ µ¿ÀÛÇÑ´Ù°í ÇÕ´Ï´Ù.


Á¦¸ñPage 44/56
2014-05   5232957   Á¤ÀºÁØ1
2015-12   1759434   ¹é¸Þ°¡
2022-10   3200   °£Àå°ÔÀå
2013-04   21712   Println
2013-08   26377   ÀÌÁ¾¼Û1
2013-11   51359   Çà¾Æ¹ü
2014-08   43267   ȸ»ó2
2019-11   7717   fprrmsl
2014-03   14623   Æ÷Ä«
2015-07   56758   EYESSHOT
2017-05   7979   ÇÑÈ¿¼®
2024-07   16202   blowes
2015-07   39283   ȲÀ籤
2017-05   7585   ±èÇö¿ì1
2021-10   4149   teps
2022-04   8848   ¸ÓÀç±ä
2011-08   15933   Á¶¿µ¹Î
2016-10   14008   ½Ì¾î¼Û¶óÀÌÅÍ
2018-01   12950   LikeTree
2021-01   5834   SDG6038
2024-07   18020   ºý½Ã´Ù
2014-08   45483   Ȳ±Ý3D