ÀÌ¹Ì cµå¶óÀ̺꿡 OS¼³Ä¡µÇ¾î ÀÖÀ» ¶§ raid 1·Î ¹­À¸·Á¸é?

Q±º   
   Á¶È¸ 29131   Ãßõ 0    

¾È³çÇϼ¼¿ä?

µ¨ 720¿¡ µ¿ÀÏÇÑ HDD°¡ µÎ°³ ´Þ·Á ÀÖ½À´Ï´Ù.
¿ø·¡ °èȹÀº Cµå¶óÀ̺ê Dµå¶óÀÌºê ³ª´²¼­ ¾²·Á°í raid·Î ¹­Áö ¾Ê°í windows server 2012¸¦ ¼³Ä¡Çß½À´Ï´Ù.

Áö±ÝÀº °èȹÀÌ ¹Ù²î¾î¼­ HDD µÎ°³¸¦ raid 1·Î ¹­°í ½ÍÀºµ¥¿ä. OS¸¦ ´Ù½Ã ¼³Ä¡ÇÏÁö ¾Ê°í ¹­À» ¼ö ÀÖÀ»±î¿ä?
¸»Â¯È² 2014-03
¾ø½À´Ï´Ù....
     
±è±ÔÁø 2014-03
¿Í¿ì ª°í ¸íÈ®ÇÑ ´äº¯ °¨»çÇÕ´Ï´Ù
AKAÁö´Ï 2014-03
Æ®·çÀ̹ÌÁö ±â¾÷¿ë¹öÀü¿¡¼­´Â ·¹À̵å Áö¿øÇÕ´Ï´Ù ½Ì±Û ¹é¾÷ÈÄ ·¹ÀÌµå ¹­°í º¹±¸,,,
Ȩ¿¡µð¼Ç¿¡¼­´Â ·¹À̵å Áö¿øÇÏÁö ¾Ê½À´Ï´Ù
     
±è±ÔÁø 2014-03
¾ÆÅ©·Î´Ï½º ¼­¹ö ¹öÀüÀÌ Àִµ¥ °°Àº ±â´ÉÀÌ ÀÖ´ÂÁö È®ÀÎÇغÁ¾ß°Ú³×¿ä..
°¨»çÇÕ´Ï´Ù^^
          
AKAÁö´Ï 2014-03
Universal Restore ¾Öµå¿ÂÀÌ ÀÖÀ¸¼Å¾ßÇÒ²®´Ï´Ù
¸»Â¯È² 2014-03
°£´ÜÇÏ°Ô ÇÒ¼ö´Â ¾øÁö¸¸¿ä.
ºÎÆ®À̹ÌÁö¸¦ ´Ù¸¥ Çϵ忡 º¹»çÇÏ½Ã°í ·¹À̵å1 Àâ°í °Å±â´Ù ´Ù½Ã Ç®¸é µË´Ï´Ù¸¸...

±×º¸´Ù »õ·Î ¼³Ä¡ Çϴ°ÍÀÌ ´õ ³ºÀ»¼öµµ ÀÖ½À´Ï´Ù...
VINCENT 2014-04
¿äÁò SSD ¸¹ÀÌ ½Ñµ¥ ÀÛÀº °Å Çϳª ±¸Çϼż­ °Å±â´Ù OS ´Ù½Ã ±ò°í ÇÏµå µÎ°³¸¦ ´Ù ¾²½Ã´Â °Ô ³´Áö ¾ÊÀ»±î¿ä?
¾Æ¹«·¡µµ OS¶õ ³ðÀº ±×´Ú Áß¿äÇÑ °Íµµ ¾Æ´Ñ °ÍÀÌ ¹®Á¦ »ý±â¸é ½Ã½ºÅÛ¿¡ Á¢±ÙÀÌ ¾Æ¾ê ¾ÈµÇ´Ï º°µµ·Î ¾²½Ã´Â°Ô...
¾Æ, ±Ùµ¥, µ¨720¿¡ SSD ´Þ ¼ö ¾ø³ª.... ÇÏ°í ã¾Æº¸´Ï Àֳ׿ä.
·¹À̵å 1ÀÌ¸é µÎ Çϵ带 ¹Ì·¯ÇØ¾ß ÇÒÅÙµ¥ ¿À¿¡½º±îÁö ¹Ì·¯ÇÏ´Â °Ç È¿À²ÀûÀÏ °Í °°Áö ¾Ê³×¿ä.
SSD°¡ »¡¶ó¾ß ÇÒ ÇÊ¿ä ¾øÀ¸´Ï±î ±¸Çü ȤÀº Áß°íµµ ±¦ÂúÀ» µí Çϳ׿ä.
½ÉÁö¾î USBµµ ±¦ÂúÀ» µí....
Àü¿¡ HP ¸¶ÀÌÅ©·Î ¼­¹ö ¾µ ¶§ USB µÎ°³ »ç¼­ °Å±â¿¡´Ù OS µÎ°³ ¼³Ä¡ÇØ ³õ±¸ ¼³Á¤µµ ¶È°°ÀÌ ÇØ ³õ±¸ Çϳª´Â ¿î¿ëÇÏ´Â µ¥, Çϳª´Â ÀÀ±Þ ¿ëÀ¸·Î Áغñ ÇØ ³õ°í ¾´ ÀûÀÌ Àֳ׿ä.
¹º ÀÏ »ý±â¸é ¹Ù·Î ¹Ù²ã ²¸¼­ °è¼Ó ÀÛµ¿½ÃÄ״µ¥, ÀÏ³â ³Ñ°Ô ¾µÀÏÀÌ ¾È »ý±â´õ±º¿ä.
ȸ¿øK 2014-04
°¡´ÉÀº Çѵ¥, ½ÇÁ¦·Î Çغ¸Áö´Â ¾Ê¾Ò½À´Ï´Ù.
LSI MegaRaid ¸Å´º¾óÀ» º¸¸é 1°³ÀÇ disk (raid 0)¿¡¼­ 2°³ÀÇ disk(raid 1) °¡´ÉÇÏ´Ù°í µÇ¾î ÀÖ½À´Ï´Ù.

Follow these steps to migrate the RAID level:
Caution: Back up any data that you want to keep before you change the RAID level of the virtual disk.
1. On the main WebBIOS CU screen, select a virtual disk.
2. Click Virtual Disks.
3. When the Virtual Disk screen appears, select Migration only (and skip to step 6) or Migration with addition in the right panel.
4. If you selected Migration with addition, select one or more physica disks from the small window in the lower right of the screen.
5. Select a new RAID level from the drop-down menu on the right. The available RAID levels are limited, based on the current RAID level of the virtual disk plus the number of physical disks available.
6. When you have made your selections, click Go at the bottom of the right panel.
7. When the message appears, confirm that you want to migrate the RAID level of the virtual disk.
A reconstruction operation begins on the virtual disk. You must wait until the reconstruction is completed before performing any other tasks in the WebBIOS CU.
ÀÌ·Ð»ó °¡´ÉÇÕ´Ï´Ù.
ÀÚü ·¹À̵å Áö¿øÇÏ´Â ¿ÜÀåÇϵ忡 ±×·± ±â´ÉÀÌ ÀÖ´Â Á¦Ç°ÀÌ ÀÖ½À´Ï´Ù.
µ¥ÀÌÅÍ°¡ µé¾îÀÖ´Â Çϵå 2°³ ²È°í, ·¹À̵å0 ¼³Á¤Çϸé, ±âÁ¸ µ¥ÀÌÅÍ ¿µ¿ªÀ» Á¦¿ÜÇÑ ³ª¸ÓÁö ºÎºÐ¿¡ ¾²±â¸¦ ½ÃÀÛÇÑ´Ù°í ÇÕ´Ï´Ù.
Áï, ±×°ÍÀ» ºÐ¸®ÇÏ¸é ·¹À̵尡 Ç®¸®Áö¸¸(2°³ÀÇ ÇϵåÀÇ µ¥ÀÌÅÍ°¡ ´Ù ³¯¾Æ°¡´Ï Àý´ë ÇÏÁö ¸» °Í), ±× ÀÚü·Î´Â óÀ½ºÎÅÍ ·¹À̵å0 ¼³Á¤ÇÑ °Íó·³ µ¿ÀÛÇÑ´Ù°í ÇÕ´Ï´Ù.


Á¦¸ñPage 43/55
2015-12   1491293   ¹é¸Þ°¡
2014-05   4954787   Á¤ÀºÁØ1
2016-01   14804   ¿ì½Î
2023-05   41070   Á¾ÀÌ°ÅÀÎ
2013-04   18662   ȸ¿øK
2017-05   9941   Àü»êÁ÷µù
2019-11   6701   öÀÌ´Ô
2021-01   5796   ĵÀ§µå
2021-05   3709   »õ·Î¿îÂ÷¿ø
2014-03   13253   ¿À³ª±â
2014-08   43731   ¯¾Æ¿Íº°ÀÌ
08-21   5739   ¿Ð»ç
2011-12   15834   ÇÏÁ¤±¸
2016-06   10157   Ãʺ¸IT
2016-10   14661   ½Ì¾î¼Û¶óÀÌÅÍ
2021-02   9011   ³ª¿ì¼Ò·¡
2022-05   15975   È­Á¤Å¥»ï
2017-05   15717   nasºÀ
2020-07   4360   ¸®µë¾Ø¹öÅÍ
2021-02   5172   1z2z
2021-10   227   ¿À¼Ò¸®
2013-11   43965   BlueApple