B110i?

   Á¶È¸ 61393   Ãßõ 3    

¾Æ±î Àü Áú°Ô ±Û·Î ÀÎÇØ B110i°¡ Á¦ ¼­¹ö¿¡ ³»ÀåµÇ ÀÖ´Â°É ¾Ë¾Ò½À´Ï´Ù

ÀÌ°É È°¼ºÈ­ ÇÏ´Â ¹æ¹ýÀÌ ÀÖ³ª¿ä?

¼ÒÇÁÆ® ·¹ÀÌµå ¶óÁö¸¸ ÀÏ´Ü µ¥ÀÌÅÍ ¾ø´Â HDD·Î ¿¬½ÀÀ» ÇØ º¼ »ý°¢À̶󼭿ä

¹ÙÀÌ¿À½º ¸Þ´º¿¡µµ ¾ø°í ¾îµô ã¾Æµµ ¾ø³×¿ä..

µµ¿ÍÁÖ¼¼¿ä
Cho Byeong Cheol
PiPPuuP 2015-01
http://h20565.www2.hp.com/hpsc/doc/public/display?docId=emr_na-c01706551

HPÀÇ B110i ¸Þ´º¾óÀÔ´Ï´Ù.

POST ÈÄ RBSU ÁøÀÔ¹æ¹ý ³ª¿ÍÀÖ½À´Ï´Ù.

¸Þ´º¾ó ÆäÀÌÁö 5ÀÇ ³»¿ëÀÔ´Ï´Ù.

HP ProLiant 100 Series servers
To enable the controller and set boot order:
1. Power up the server.
2. When prompted during the start-up sequence, access RBSU by pressing the F10 key.
3. Select Advanced or Advanced Settings.
4. Select SATA Configuration or Hard Drive Configuration.
5. Change SATA #1 to RAID.
6. Return to the previous screen by pressing the Escape key.
7. Select the Boot Menu by pressing the right arrow key.
8. Select Hard Disk Drives.
9. To assign the HP Smart Array B110i SATA RAID Controller as the boot controller, set Ctrl 1 to HP
Smart Array B110i SATA RAID Controller.
10. Press the F10 key to save the setting and to exit RBSU.


HP ProLiant 300 Series servers
To enable the controller and set boot order:
1. Power up the server.
2. When prompted during the start-up sequence, access RBSU by pressing the F9 key.
3. Select Advanced Settings.
4. Select Embedded SATA RAID.
5. Select Enabled.
6. Return to the previous screen by pressing the Escape key.
7. Select Boot Controller Order.
8. To assign the HP Smart Array B110i SATA RAID Controller as the boot controller, set Ctrl 1 to HP
Smart Array B110i SATA RAID Controller.
9. Press the F10 key to save the settings and to exit RBSU
     
Á¶º´Ã¶ 2015-01
°¨»çÇÕ´Ï´Ù
     
Á¶º´Ã¶ 2015-01
ÀÏ´Ü ¾îµå¹ê½ºµå¿¡¼­ RAID·Î ¼³Á¤Çϱä Çߴµ¥ ÀÌ ÀÌÈÄ¿¡¼­ ¸·Çû½À´Ï´Ù..
          
PiPPuuP 2015-01
¼³Á¤ÇϼÌÀ¸¸é ´ÙÀ½ ºÎÆúÎÅÍ RAIDÄÁÆ®·Ñ·¯°¡ µ¿ÀÛÇÕ´Ï´Ù.
Æ÷½ºÆà ÈÄ ORCA(Option ROM Configuration for Arrays)µé¾î°¡¼Å¼­ Logical Drive¸¦ ÀâÀ¸½Ã¸é µË´Ï´Ù.


´ÙÀ½Àº µ¿ÀÏ ¸Þ´º¾ó 6ÆäÀÌÁö ³»¿ëÀÔ´Ï´Ù.

To create a logical drive using ORCA:
1. Power up the server.
2. When prompted during the start-up sequence, access ORCA by pressing the F8 key.
3. Select Create Logical Drive.
The screen displays a list of all unconfigured physical drives and the valid RAID options for the
system.
4. Use the Arrow keys, Spacebar, and Tab key to navigate around the screen and set up the logical
drive, including an online spare drive, if one is required.
NOTE: You cannot use ORCA to configure one spare drive to be shared among several
arrays. Only ACU enables you to configure shared spare drives.
5. Press the Enter key to accept the settings.
Enabling and configuring the controller 7
6. Press the F8 key to confirm the settings and save the new configuration.
After several seconds, the Configuration Saved screen appears.
7. Press the Enter key to continue.
Repeat this procedure to create additional logical drives.

¸¸¾à POSTÈÄ F8Å°¸¦ ÅëÇÑ ORCAÁøÀÔÀÌ ¾ÈµÈ´Ù¸é ´Ù½Ã RBSU¿¡ ÁøÀÔÇϼż­ ·¹À̵åÄÁÆ®·Ñ·¯¸¦ ºÎÆÃÄÁÆ®·Ñ·¯·Î Á¦´ë·Î Àâ¾Æ³õ¾Ò´ÂÁö È®ÀÎÇغ¸½Ã±â ¹Ù¶ø´Ï´Ù.
               
Á¶º´Ã¶ 2015-01
9. To assign the HP Smart Array B110i SATA RAID Controller as the boot controller, set Ctrl 1 to HP
Smart Array B110i SATA RAID Controller.

¿©±â¼­ ºÎÅÍ ¸·Çû¾î¿ä..

Advanced

Harddisk Configuration

SATA Mode Selection [RAID]

ÇÏ°í Boot ¸Þ´º ÂÊÀ» º¸¸é B110i ¶ó´Â ±ÛÀڴ ã¾Æº¼ ¼ö°¡ ¾ø³×¿ä ¤Ð¤Ð¤Ð¤Ð¤Ð¤Ð

Ctrl 1ÀÌ ¹» ÀǹÌÇÏ´ÂÁö µµÅë ÀÌÇØ°¡..

¾î¶»°Ô ÇÏ¸é µÇ³ª¿ä..
                    
PiPPuuP 2015-01
http://h20564.www2.hp.com/hpsc/doc/public/display?docId=emr_na-c03611198

ÂüÁ¶ÇϽðí¿ä...

b100i¶ó°í ¾È³ª¿À°í RAID:Smart Array·Î ³ª¿Ã°Ì´Ï´Ù.
±×°É ÀçÀÏ Ã¹¹ø°¿¡ µÎ¸é ºÎÆÃÀ» ·¹À̵忡¼­ ÇÕ´Ï´Ù.
                         
Á¶º´Ã¶ 2015-01
Çä.. ¾ÆÁ÷ ¾È ÁÖ¹«½Ã°í °è¼Ì±º¿ä..

¹®Á¦´Â Àú·± ±ÛÀÚ Çϳªµµ ã¾Æ º¼ ¼ö°¡ ¾ø½À´Ï´Ù;;;;

ÀÚ²Ù ½Å¼¼¸¸ Áö°Ô µÇ´Â °Í °°½À´Ï´Ù...
                    
PiPPuuP 2015-01
4,5¹ø ´Ù½Ã Çغ¸¼¼¿ä.
·¹À̵åÄÁÆ®·Ñ·¯°¡ ¾ÆÁ÷ disableµÇ¾îÀִµí ÇÕ´Ï´Ù.
                         
Á¶º´Ã¶ 2015-01
5. Change SATA #1 to RAID

¿©±â¼­ Á¦ °æ¿ì¿£

¸Þ´º¸íÀÌ
Harddisk Configuration

·¹ÀÌµå ¿É¼ÇÀ¸·Î ¹Ù²Ù´Â °ÍÀÌ
SATA Mode Selection [RAID]

ÀÌ·¸°Ô ¶å´Ï´Ù..

ÀÌ·¸°Ô ÇÏ°í ºÎÆ® ºÎºÐ¿¡ °¡ ºÁµµ ÈÕ Çϳ׿ä

DL120 G6Àε¥

¹ÙÀÌ¿À½º³ª Æß¿þ¾î°¡ ±¸¹öÀüÀ̶ó ±×·± °Í °°½À´Ï´Ù

HP ȨÆäÀÌÁöó·³ ¹ÙÀÌ¿À½º°¡ »ý°Ü¸ÔÁö ¾Ê¾Ò±¸¿ä..

Hard Drive Çϸ鼭 µå·Ó´Ù¿î ¸Þ´º ¹æ½ÄÀÔ´Ï´Ù..


±×³É HP¿¡ ÀüÈ­ Çѹø ÇØ ºÁ¾ß°Ú½À´Ï´Ù..

ÀÌÀü¿¡ ´Ù¸¥ ÀÏ ‹š¹®¿¡ ³»Àå ·¹À̵尡 Àִٴ°ŠȮ½ÇÈ÷ µé¾ú°Åµç¿ä..

°ü·Ã ³»¿ë ´Ù½Ã µè°í µ¡±Û·Î ȸ½ÅÇÏ°Ú½À´Ï´Ù..

»õº®¿¡ ½Å¼¼¸¦ ³Ê¹« ¸¹ÀÌ Áø °Í °°½À´Ï´Ù

Á¶¾ð°ú µµ¿ò °¨»çÇÕ´Ï´Ù
                    
PiPPuuP 2015-01
º° µµ¿òÀÌ ¸øµÇ¾î¼­ Á˼ÛÇÕ´Ï´Ù.

°ü·Ã Ä¿¹Â´ÏƼ¸¦ º¸´Ï
http://h30499.www3.hp.com/t5/ProLiant-Servers-ML-DL-SL/DL120-G6-gt-Setup-RAID/td-p/5219767
»ç¿ëÇϱâ À§Çؼ­´Â ÃÖ½ÅÀÇ Æß¿þ¾î¿Í µå¶óÀ̹ö°¡ ÇÊ¿ä·Î ÇÏ´Ù°í Çϴ±º¿ä.


Á¦¸ñPage 36/55
2014-05   4964089   Á¤ÀºÁØ1
2015-12   1500541   ¹é¸Þ°¡
2015-03   29606   ÂÞÂÞºÀ
2015-03   16189   ÃÑ°¢
2015-02   50469   ¾ßä
2015-02   55678   Èæ°õµ¹ÀÌ
2015-02   54476   ½ÅÀº¿Ö
2015-01   75837   ¾Æµå·¹³¯¸°
2015-01   59249   ¸ø»ý±ä¾Ö
2015-01   61087   ¿¬¹Î¾Æºü
2015-01   61394   Á¶º´Ã¶
2015-01   49880   Àϸ®ÄÉ
2015-01   50219   °¨±â
2015-01   47662   ÆÄ¿À¸®
2015-01   22999   À±´ö°æ
2015-01   31166   ¾Æµå·¹³¯¸°
2015-01   19133   À±´ö°æ
2015-01   26428   ’ÀÃÑÃ
2015-01   12128   À±´ö°æ
2015-01   39563   ±Â
2015-01   46897   nova
2015-01   12331   À±´ö°æ