(광고) 단통법 시대의 인터넷가입 가이드(ver2.0) (234) |
백메가 |
2015-12 |
1737890 |
25 |
2015-12
1737890
1 백메가
|
|
[필독] 처음 오시는 분을 위한 안내 (736) |
정은준1 |
2014-05 |
5205801 |
0 |
2014-05
5205801
1 정은준1
|
1062 |
Raid 6 질문이요 (7) |
서버하수 |
2023-07 |
54209 |
0 |
2023-07
54209
1 서버하수
|
1061 |
질문) Dell h710p 카드를 PC에 장착시 인식 오류 (8) |
네온7 |
2023-06 |
51418 |
0 |
2023-06
51418
1 네온7
|
1060 |
HDD 고장 후 RAID5 복구중입니다. (7) |
땅쟁이 |
2023-06 |
32269 |
0 |
2023-06
32269
1 땅쟁이
|
1059 |
R720 SSD RAID 속도 괜찮게 나온건가요?? (4) |
전산직딩 |
2023-06 |
41060 |
0 |
2023-06
41060
1 전산직딩
|
1058 |
XR450C-MX 2G 레이드카드 써보신분 계실까요? (2) |
naan |
2023-05 |
44787 |
0 |
2023-05
44787
1 naan
|
1057 |
raid5 복구 문의 (14) |
여수21 |
2023-05 |
46291 |
0 |
2023-05
46291
1 여수21
|
1056 |
LSI 9361-8i 부팅화면 내용이 차이가 나는데...? (5) |
종이거인 |
2023-05 |
41747 |
0 |
2023-05
41747
1 종이거인
|
1055 |
H710p mini SSD RAID5 구성시 캐쉬 써야 할까요? (7) |
전산직딩 |
2023-05 |
34063 |
0 |
2023-05
34063
1 전산직딩
|
1054 |
8BAY 통으로 RAID5 or RAID6 가 빠른가요 4bay raid5 씩 파티션 짜는게 빠를까요? (15) |
전산직딩 |
2023-05 |
35301 |
0 |
2023-05
35301
1 전산직딩
|
1053 |
GRAID SupremeRAID SR-1010 리빌드 테스트 (RAID-5/6) (1) |
송주환 |
2023-05 |
22850 |
0 |
2023-05
22850
1 송주환
|
1052 |
nvme raid SupremeRAID 안정성이 어떤가요? (23) |
naan |
2023-04 |
44260 |
0 |
2023-04
44260
1 naan
|
1051 |
Non-RAID에서 백업을 한 이미지를 RAID(미러)구성후 복원할 방법이 없을까요?(수정) (3) |
축복소년 |
2023-04 |
25394 |
0 |
2023-04
25394
1 축복소년
|
1050 |
Non-RAID에서 백업을 한 이미지를 RAID(미러)구성후 복원할 방법이 없을까요? (7) |
축복소년 |
2023-04 |
24680 |
0 |
2023-04
24680
1 축복소년
|
1049 |
레이드 캐쉬 관련 질문 드립니다 (4) |
mvwiz |
2023-03 |
33819 |
0 |
2023-03
33819
1 mvwiz
|
1048 |
케이블 규격 문의드려요 (14) |
다이다이 |
2023-03 |
45220 |
0 |
2023-03
45220
1 다이다이
|
1047 |
Dell R720 (PERC H710p mini) - IT mode RAID-5 구축기 (2) |
remonemo |
2023-03 |
46214 |
0 |
2023-03
46214
1 remonemo
|
1046 |
아레카 arc 1831x 사용중 하드가 나간걸까요... (9) |
chamgileam |
2023-03 |
32154 |
0 |
2023-03
32154
1 chamgileam
|
1045 |
레이드 5, 6 구성 비활성화 (7) |
Dante0001 |
2023-03 |
28796 |
0 |
2023-03
28796
1 Dante0001
|
1044 |
HighPoint 6314A 질문입니다. 고수님들 조언 부탁드립니다. (9) |
마운1 |
2023-02 |
32799 |
0 |
2023-02
32799
1 마운1
|
1043 |
SATA SSD RAID-5 문의 (13) |
remonemo |
2023-02 |
61223 |
0 |
2023-02
61223
1 remonemo
|
MegaSCU로 mfc.ini 추출해서 확인하시고 0으로 설정되어있으면 1로 변경 후 적용하시면 됩니다.
https://drive.google.com/file/d/0BwTaEgD3WAZqYmJpNzZRVnltcTA/view?usp=sharing
1. 명령프롬프트(관리자)
MegaSCU -adpsettings -write -f mfc.ini -a0 입력
2. 생성된 mfc.ini 열어서 biosEnumerateLds=0 으로 되어있다면 biosEnumerateLds=1로 수정
3. 명령프롬프트(관리자)
MegaSCU -adpsettings -read -f mfc.ini -a0 입력
4. 재부팅 후 MegaRAID BIOS Post에서 디스크 정보가 뜨는지 확인
만약 위 설정이 이미 =1로 되어있다면 POST 정보가 나오는 카드의 mfc.ini를 추출해서 안나오는 카드에 적용해보시길 바랍니다.
액세스 권한 필요
액세스를 요청하거나 액세스 권한이 있는 계정으로 전환하세요.
구글신 도움으로 파일 구해서 실행
D:\Downloads\lsi_win>MegaSCU -adpsettings -write -f mfc.ini -a0
ERROR:Could not detect controller.
Failed to get ControllerId List.
Failed to get CpController object.
Exit Code: 0x01
D:\Downloads\lsi_win>MegaSCU -adpcount
Controller Count: 0.
Exit Code: 0x00
D:\Downloads\lsi_win>
raid card가 없다고 나오는데 어떻게 해야할지..?
2개의 raid card가 동일합니다.
MegaSCU 에서는 인식을 못하고,
MegaCli 에서는 인식해서 정보를 뿌리고.
Controller Count: 1.
Exit Code: 0x01
D:\Downloads\lsi_win>MegaCli -AdpAllInfo -a0
Adapter #0
==============================================================================
Versions
================
Product Name : AVAGO MegaRAID SAS 9361-8i
Serial No : SK73079966
FW Package Build: 24.21.0-0159
Mfg. Data
================
Mfg. Date : 07/29/17
Rework Date : 00/00/00
Revision No : 14C
Battery FRU : N/A
Image Versions in Flash:
================
BIOS Version : 6.36.00.3_4.19.08.00_0x06180206
Ctrl-R Version : 5.19-0609
Preboot CLI Version: 01.07-05:#%0000
FW Version : 4.680.00-8577
NVDATA Version : 3.1705.00-0028
Boot Block Version : 3.07.00.00-0004
Pending Images in Flash
================
None
PCI Info
================
Controller Id : 0000
Vendor Id : 1000
Device Id : 005d
SubVendorId : 1000
SubDeviceId : 936c
Host Interface : PCIE
ChipRevision : C0
Number of Frontend Port: 0
Device Interface : PCIE
Number of Backend Port: 8
Port : Address
0 50000393b8c9c042
1 50000393b8ca1882
2 5000039398c90a0e
3 50000393b8ca191a
4 0000000000000000
5 0000000000000000
6 0000000000000000
7 0000000000000000
HW Configuration
================
SAS Address : 500605b00d2a60f0
BBU : Present
Alarm : Present
NVRAM : Present
Serial Debugger : Present
Memory : Present
Flash : Present
Memory Size : 1024MB
TPM : Absent
On board Expander: Absent
Upgrade Key : Absent
Temperature sensor for ROC : Present
Temperature sensor for controller : Absent
ROC temperature : 87 degree Celcius
Settings
================
Current Time : 14:39:29 5/13, 2023
Predictive Fail Poll Interval : 300sec
Interrupt Throttle Active Count : 16
Interrupt Throttle Completion : 50us
Rebuild Rate : 30%
PR Rate : 30%
BGI Rate : 30%
Check Consistency Rate : 30%
Reconstruction Rate : 30%
Cache Flush Interval : 4s
Max Drives to Spinup at One Time : 2
Delay Among Spinup Groups : 12s
Physical Drive Coercion Mode : Disabled
Cluster Mode : Disabled
Alarm : Enabled
Auto Rebuild : Enabled
Battery Warning : Enabled
Ecc Bucket Size : 15
Ecc Bucket Leak Rate : 1440 Minutes
Restore HotSpare on Insertion : Disabled
Expose Enclosure Devices : Enabled
Maintain PD Fail History : Enabled
Host Request Reordering : Enabled
Auto Detect BackPlane Enabled : SGPIO/i2c SEP
Load Balance Mode : Auto
Use FDE Only : Yes
Security Key Assigned : No
Security Key Failed : No
Security Key Not Backedup : No
Default LD PowerSave Policy : Controller Defined
Maximum number of direct attached drives to spin up in 1 min : 10
Auto Enhanced Import : Yes
Any Offline VD Cache Preserved : No
Allow Boot with Preserved Cache : No
Disable Online Controller Reset : No
PFK in NVRAM : Yes
Use disk activity for locate : No
POST delay : 90 seconds
Capabilities
================
RAID Level Supported : RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span
Supported Drives : SAS, SATA
Boot Volume Supported : NO
Allowed Mixing:
Mix in Enclosure Allowed
Mix of SAS/SATA of HDD type in VD Allowed
Mix of SAS/SATA of SSD type in VD Allowed
Mix of SSD/HDD in VD Allowed
Status
================
ECC Bucket Count : 0
Limitations
================
Max Arms Per VD : 32
Max Spans Per VD : 8
Max Arrays : 128
Max Number of VDs : 64
Max Parallel Commands : 928
Max SGE Count : 60
Max Data Transfer Size : 512 sectors
Max Strips PerIO : 128
Max LD per array : 16
Min Strip Size : 64 KB
Max Strip Size : 1.0 MB
Max Configurable CacheCade Size: 1024 GB
Current Size of CacheCade : 0 GB
Current Size of FW Cache : 629 MB
Device Present
================
Virtual Drives : 1
Degraded : 0
Offline : 0
Physical Devices : 5
Disks : 4
Critical Disks : 0
Failed Disks : 0
Supported Adapter Operations
================
Rebuild Rate : Yes
CC Rate : Yes
BGI Rate : Yes
Reconstruct Rate : Yes
Patrol Read Rate : Yes
Alarm Control : Yes
Cluster Support : No
BBU : Yes
Spanning : Yes
Dedicated Hot Spare : Yes
Revertible Hot Spares : Yes
Foreign Config Import : Yes
Self Diagnostic : Yes
Allow Mixed Redundancy on Array : No
Global Hot Spares : Yes
Deny SCSI Passthrough : No
Deny SMP Passthrough : No
Deny STP Passthrough : No
Support Security : Yes
Snapshot Enabled : No
Support the OCE without adding drives : Yes
Support PFK : Yes
Support PI : Yes
Support Boot Time PFK Change : No
Disable Online PFK Change : No
Support LDPI Type1 : No
Support LDPI Type2 : No
Support LDPI Type3 : No
PFK TrailTime Remaining : 0 days 0 hours
Support Shield State : Yes
Block SSD Write Disk Cache Change: Yes
Point In Time Progress: Yes
Supported VD Operations
================
Read Policy : Yes
Write Policy : Yes
IO Policy : Yes
Access Policy : Yes
Disk Cache Policy : Yes
Reconstruction : Yes
Deny Locate : No
Deny CC : No
Allow Ctrl Encryption: No
Enable LDBBM : Yes
Support Breakmirror : Yes
Power Savings : No
Supported PD Operations
================
Force Online : Yes
Force Offline : Yes
Force Rebuild : Yes
Deny Force Failed : No
Deny Force Good/Bad : No
Deny Missing Replace : No
Deny Clear : No
Deny Locate : No
Support Temperature : Yes
NCQ : Yes
Disable Copyback : No
Enable JBOD : No
Enable Copyback on SMART : No
Enable Copyback to SSD on SMART Error : Yes
Enable SSD Patrol Read : No
PR Correct Unconfigured Areas : Yes
Enable Spin Down of UnConfigured Drives : Yes
Disable Spin Down of hot spares : No
Spin Down time : 30
T10 Power State : No
Error Counters
================
Memory Correctable Errors : 0
Memory Uncorrectable Errors : 0
High Availability Properties
================
Topology Type : None
Cluster Information
================
Cluster Permitted : No
Cluster Active : No
Default Settings
================
Phy Polarity : 0
Phy PolaritySplit : 0
Background Rate : 30
Strip Size : 256kB
Flush Time : 4 seconds
Write Policy : WB
Read Policy : RA
Cache When BBU Bad : Disabled
Cached IO : No
SMART Mode : Mode 6
Alarm Disable : Yes
Coercion Mode : None
ZCR Config : Unknown
Dirty LED Shows Drive Activity : No
BIOS Continue on Error : Yes
Spin Down Mode : None
Allowed Device Type : SAS/SATA Mix
Allow Mix in Enclosure : Yes
Allow HDD SAS/SATA Mix in VD : Yes
Allow SSD SAS/SATA Mix in VD : Yes
Allow HDD/SSD Mix in VD : Yes
Allow SATA in Cluster : No
Max Chained Enclosures : 16
Disable Ctrl-R : No
Enable Web BIOS : No
Direct PD Mapping : No
BIOS Enumerate VDs : Yes
Restore Hot Spare on Insertion : No
Expose Enclosure Devices : Yes
Maintain PD Fail History : Yes
Disable Puncturing : No
Zero Based Enclosure Enumeration : No
PreBoot CLI Enabled : No
LED Show Drive Activity : Yes
Cluster Disable : Yes
SAS Disable : No
Auto Detect BackPlane Enable : SGPIO/i2c SEP
Use FDE Only : Yes
Enable Led Header : Yes
Delay during POST : 0
EnableCrashDump : Yes
Disable Online Controller Reset : No
EnableLDBBM : Yes
Un-Certified Hard Disk Drives : Allow
Treat Single span R1E as R10 : No
Max LD per array : 16
Power Saving option : Don't Auto spin down Configured Drives
Max power savings option is not allowed for LDs. Only T10 power conditions are to be used.
Default spin down time in minutes: 30
Enable JBOD : No
TTY Log In Flash : No
Auto Enhanced Import : Yes
BreakMirror RAID Support : Yes
Disable Join Mirror : Yes
Enable Shield State : Yes
Time taken to detect CME : 60s
Exit Code: 0x00
D:\Downloads\lsi_win>
그대로 사용하시면 않되구요..
Raid 정보를 불러들여야 합니다.