´ÙÀ½°ú °°ÀÌ ÆÄ¿ö¸¦ ±³Ã¼Çϸé Á» ±¦ÂúÀ»·±Áö..?

±è¸í¿í   
   Á¶È¸ 11772   Ãßõ 17    

¾È³çÇϼ¼¿ä.

2469UGN µà¾ó, RAID¿¡ Çϵå 4°³¸¦ ¹­¾î¼­ »ç¿ëÇÏ°í Àִµ¥
1ÁÖÀÏ¿¡ Çѹø ²Ã·Î
---------------------------------------
SCSI ID 4  3ware 7506-4LP ATA RAID Controller
   Array Unit 0  Striped with Parity 64K (RAID 5)  480.12 GB   Degraded
      Port 0 SAMSUNG SV1604N    160.04 GB   OK
      Port 1 SAMSUNG SV1604N    160.04 GB   Not in Service
      Port 2 SAMSUNG SV1604N    160.04 GB   OK
      Port 3 SAMSUNG SV1604N    160.04 GB   OK
---------------------------------------
ÀÌ·± ¿¡·¯°¡ »ý±â´Â ±º¿ä.
¸Þ½ÃÁö´Â
---------------------------------------
ERROR: Disk Array Unit 0 on controller ID:4 is degraded and no longer fault tolerant. Check log for drive errors. (0x2)
ERROR: Drive error encountered on port 1 on controller ID:4. Check cables and drives for media errors. (0xa)
---------------------------------------
ÀÌ·¸±¸¿ä.

±×·³ Àü ´Ù½Ã rebuild Çؼ­ »ç¿ëÇϴµ¥.. Âü ºÒ¾ÈÇϳ׿ä.
ÀǽɵǴ °ÍÀ̶ó°í´Â ÆÄ¿ö¹Û¿¡ ¾ø´Âµ¥.

Heroichi HEC-350VD-TÀ» »ç¿ëÇÏ°í ÀÖ½À´Ï´Ù. ±×·±µ¥ ÀÌ Á¦Ç°ÀÌ Combined Power°¡ 180W±º¿ä..
¼¼ÄÁÄÄ¿¡´Â À߸¸ ZM300A-APFÀε¥ Combined Power°¡ 280WÀ̳׿ä.
ÆÄ¿ö°¡ ´õ ³·Àº°Ô Combined power´Â ³ô°í Àß ÀÌÇØ°¡ ¾ÈµÇµ¥¿ä..

µÎ°³¸¦ ±³Ã¼ÇÏ¿© À߸¸ÆÄ¿ö·Î »ç¿ëÇϸé À§¿Í °°Àº »óȲÀÌ ¹ß»ýÇÏÁö ¾ÊÀ»Áö.. ±Ã±ÝÇؼ­ Áú¹® µå¸³´Ï´Ù.

¾Æ¹«·¡µµ 400WÀÌ»óÀÇ Á¦Ç°À» »ì ¿©°ÇÀº Áö±Ý ¾ÈµÇ±¸¿ä..

»õÇØ º¹ ¸¹ÀÌ ¹ÞÀ¸½Ã±¸¿ä. ÀоîÁּż­ °¨»çÇÕ´Ï´Ù.
ªÀº±Û Àϼö·Ï ½ÅÁßÇÏ°Ô.


QnA
Á¦¸ñPage 5284/5685
2015-12   1505546   ¹é¸Þ°¡
2014-05   4969204   Á¤ÀºÁØ1
2012-10   5431   ¹æoÈ¿o¹®
2016-10   5397   ºí·ç¿µ»ó
2021-09   3029   hdsniper
2012-10   6779   À±Ä¡¿­
2014-07   4128   ¹«Á»ÇÔ´ë
2015-11   4063   ¿©ÁÖÀÌ»óµ·
2020-04   2900   GoverZG
2021-09   1808   ±¸¿ô
2009-09   11767   Èû³»¿ë
2020-04   3289   Å×Ã÷
2023-04   1841   ÀÌâÁØ
2009-09   6106   Â÷Áø
2019-02   4300   ¾Æ¸¶Ä«½Ã
2015-11   6490   °Ü¿ï³ª¹«
2020-05   4522   Å×Ã÷
2019-03   12536   ºÎ»êÃʺ¸
2016-11   4551   DOSS
2009-11   7155   ±èÀå¿ì
2014-08   5719   Å×µ¹¾ÆÀÌ
2015-12   6922   ǪÇÏÈ÷