Sun 3800 서버를 데탑에서 제어 하기 위해 하이퍼터미널로 접속하였는데요
파워전원만 켠 상태로 하이퍼터미널에 접속하니 서버를 테스트 한 이후 맨 아래 처럼 Input: 에서 커서만 깜막거리고 진행도 안돼고 명령어 입력도 안돼는 상황입니다.
서버의 LED는 모두 정상으로 표시되어 있구요.
명령어 입력이 되야 서버를 켤텐데 대략 난감입니다.
이상황이 어떤 상황인지 아시는 홴님 계시면 자세한 설명좀 부탁드리구요.
처리방법 좀 알려주세요~~
Hardware Reset...
@(#) SYSTEM CONTROLLER(SC) POST 19 2001/08/08 14:42
PSR = 0x044010e5
PCR = 0x04004000
SelfTest running at DiagLevel:0x20
SC Boot PROM Test
BootPROM CheckSum Test
IU Test
IU instruction set Test
Little endian access Test
FPU Test
FPU instruction set Test
SparcReferenceMMU Test
SRMMU TLB RAM Test
SRMMU TLB Read miss Test
SRMMU page probe Test
SRMMU segment probe Test
SRMMU region probe Test
SRMMU context probe Test
IIep Internal Cache Test
DCACHE RAM access Test
DCACHE TAG access Test
DCACHE Read miss Test
DCACHE Read hit Test
DCACHE Write miss Test
DCACHE Write hit Test
ICACHE RAM access Test
ICACHE TAG access Test
ICACHE miss Test
ICACHE hit Test
ICACHE TAG flush Test
PCIC Test
PCIC Probe Test
PCIC Config Register Access Test
PCI Master Abort Test
PCIC Init Test
Memory Test
Memory Address Test
RIO Ebus Test
Rio Ebus Probe Test
RIO Ethernet Test
Rio Enet Probe Test
Rio Ethernet Int Loopbacks Test
DUART(16552) InterSC Test
Loopback Test
COM3 port
COM4 port
Interrupt Test
COM3 port Intr #2
COM4 port Intr #2
System Clock Test
System Clock verify Test
Board0 Clock is selected
75MHZ Fixed Crystal is the selected Clock Source
CLK(Self) :0x0000ffff CLK(Other) : 0x00000000
REF : 0x0000222c
CLOCK(SELF) FREQ : 74.91 MHZ
CLOCK(OTHER) FREQ : 0.0 MHZ
SBBC PCI Controller Test
SBBC PCI Config Space probe Test
SBBC Internal Reg Access Test
SBBC Interrupts Test
Port1 interrupt generation Tests INTR #14
Port0 interrupt generation Tests INTR #14
SBBC Device0 Test
PS Fail Reg(SBBC Dev0) Test
SBBC Device1 Test
SRAM (SBBC Dev1) Test
Memory Address Test (Non-destructive)
SBBC Device2 Test
BId&MFG Reg (SBBC Dev2) Test
SBBC Device3 Test
FRU Prsnt Reg (SBBC Dev3) Test
SBBC Device5 Test
EPLD (SBBC Dev5) Test
TOD(M48T59) Test
TOD Init Test
TOD Functional Test
TOD NVRAM(Non-Destructive) Test
TOD Interrupts Test
I2C Register Access Test
Enable Mux Register Test
Channel Mux Register Test
Add Command Register Test
Data Register Test
Local I2C AT24C64 Test
EEPROM Device Test
performing eeprom sequential read
Local I2C PCF8591 Test
VOLT_AD Device Test
channel[00000001] Voltage(0x00000099) :1.49
channel[00000002] Voltage(0x0000009B) :3.33
channel[00000003] Voltage(0x00000099) :4.98
channel[00000004] Voltage(0x00000000) :0.0
Local I2C LM75 Test
TEMP0(IIep) Device Test
Temparature : 47.0 Degree(C)
Local I2C LM75 Test
TEMP1(Rio) Device Test
Temparature : 38.50 Degree(C)
Local I2C LM75 Test
TEMP2(CBH) Device Test
Temparature : 55.50 Degree(C)
Local I2C PCF8574 Test
Sc CSR Device Test
Console Bus Hub Test
CBH Register Access Test
POST Complete.
ERI Device Present
Getting MAC address for SSC0
MAC address is 0:3:ba:d:82:d3
Hostname: eagle_tornado-sc
Address: 10.250.7.32
Netmask: 255.255.255.0
Attached TCP/IP interface to eri unit 0
Attaching interface lo0...done
Gateway: 10.250.7.1
Timeout waiting for network driver (flags=0x8062)
Adding 2854 symbols for standalone.
Copyright 2001 Sun Microsystems, Inc. All rights reserved.
Sun Fire 3800-6800 System Controller
RTOS version: 19
ScApp version: 5.12.5
SC POST diag level: min
The date is Saturday, June 12, 2010, 12:29:39 AM PDT.
Jun 12 00:29:40 eagle_tornado-sc Platform.SC: Boot: ScApp 5.12.5, RTOS 19
Jun 12 00:29:42 eagle_tornado-sc Platform.SC: SBBC Reset Reason(s): Power On Res
et
Jun 12 00:29:42 eagle_tornado-sc Platform.SC: Initializing the SC SRAM
Jun 12 00:29:45 eagle_tornado-sc Platform.SC: Clock Source: 75MHz
Jun 12 00:29:47 eagle_tornado-sc Platform.SC: Master System Controller
Jun 12 00:29:52 eagle_tornado-sc Platform.SC: Chassis is in dual partition mode.
Jun 12 00:29:52 eagle_tornado-sc Platform.SC: Cold boot detected: Configuring do
mains from NVCI
Domain: A keyswitch standby
Domain: C keyswitch standby
Jun 12 00:29:56 eagle_tornado-sc Platform.SC: NOTICE: FT0 has no grid power
Jun 12 00:29:57 eagle_tornado-sc Platform.SC: NOTICE: FT1 has no grid power
Jun 12 00:29:57 eagle_tornado-sc Platform.SC: NOTICE: FT2 has no grid power
Jun 12 00:29:57 eagle_tornado-sc Platform.SC: NOTICE: FT3 has no grid power
System Controller 'eagle_tornado-sc':
Type 0 for Platform Shell
Type 1 for domain A console
Type 2 for domain B console
Type 3 for domain C console
Type 4 for domain D console
Input:
Input: Jun 12 00:37:26 eagle_tornado-sc Platform.SC: Frame Manager monitorin
g is disabled, communication error
µ¥Å¾¿¡¼´Â ½Ã¸®¾ó ÄÉÀÌºí¿¡ 9ÇÉ-25ÇÉ Á¨´õ¿¡ null modem ¿¬°áÇÏ¸é ¾Æ¹«°Íµµ ÀÔ·ÂÀÌ µÇÁú ¾Ê½À´Ï´Ù ¤»¤»