전원이 나갈때 마다 날짜/시간 정보를 재설정해야 하는데
본래 이런 건 가요?
ªÀº±Û Àϼö·Ï ½ÅÁßÇÏ°Ô.
System -> NTP Client ¿¡¼­
unicast ¸ðµå·Î 211.233.84.186 ¾ÆÀÌÇÇ Çϳª Ãß°¡ÇØ ÁÖ¼¼¿ä.
ÀÌÅ¿í 2014-02
NTP Client¸¦ ¼³Á¤ÇÏÁö ¾ÊÀ¸¸é Àç¼³Á¤ µÇ´Â°Ô Á¤»óÀÔ´Ï´Ù.
Å͹̳ο¡¼­ ¾Æ·¡ÀÇ ¸í·É¾î¸¦ ÀÔ·ÂÇϽøé ÆíÇÕ´Ï´Ù.
¶ÇÇÑ Time Zone¸¦ ¼³Á¤ÇØ ÁÖ´Â°Ô ÁÁ½À´Ï´Ù.

/system clock
set time-zone-name=Asia/Seoul

/system ntp client
set enabled=yes mode=unicast primary-ntp=211.233.84.186 secondary-ntp=203.248.240.103
     
Ãá°í 2014-02
Áö³ª°¡´Ù Ãʺ¸µµ ¾ÆÁÖ ÁÁÀº Á¤º¸ ¾Ë°í °©´Ï´Ù.
±×·±µ¥ ¾Ë·ÁÁֽŠĿ¸Çµå Áß¿¡¼­

/system clock ±îÁö´Â Àß °¡´Âµ¥
set time-zone.name=asia/seoul Àº ¸í·É¾î°¡ ¾Èµé¾î°¡³×¿ä

¹Ø¿¡ÁÙ NTP ´Â Àß µé¾î°¬´Âµ¥ 
Á¦°¡ ¹º°¡¸¦ À߸ø ÇÑ°ÍÀϱî¿ä?
          
ÀÌÅ¿í 2014-02
set time-zone.name =>set time-zone-name ÀÔ´Ï´Ù.
Å͹̳ο¡¼­ ¾ÈµÈ´Ù¸é WinBox¿¡¼­´Â System->ClockÀÇ Time ÅÇ¿¡¼­ Time Zone Name¿¡¼­ ¼±ÅÃÀÌ °¡´ÉÇÕ´Ï´Ù.
               
Ãá°í 2014-02
Çä . Àº ¿ÀŸ ÀÔ´Ï´Ù.
¾Ë·ÁÁֽŠNTP ÀÔ·ÂÀ¸·Î ŸÀÓ ¼³Á¤À» ÀߵȰŠ°°½À´Ï´Ù.

¾Æ ±×¸®°í ´ë¹®ÀÚ ¼Ò¹®ÀÚ ÀÔ·ÂÀÌ Á¤È®ÇØ¾ß ÇÏ´Â ±º¿ä
ÁÁÀº Á¤º¸ ÁֽŰŠ°¨»ç µå¸³´Ï´Ù.
±è»ó¹Î 2014-02
°í¸¿½À´Ï´Ù.
  WinBox·Î Á¢¼ÓÇØ ¼ÂÆà ÇÏ°í ²ô°í ´Ù½Ã ÄÑ º¸´Ï
Á¦´ë·Î µË´Ï´Ù.


QnA
Á¦¸ñPage 3210/5657
2014-05   4859665   Á¤ÀºÁØ1
2015-12   1404903   ¹é¸Þ°¡
2016-01   3686   c4066
2014-09   11377   ±Ù¿øe
2016-01   4186   ¼­¿ïI±èµ¿¼ö
2019-04   4338   VSPress
2014-10   4816   ³ªÆÄÀÌ°­½ÂÈÆ
2016-01   3585   ÇÏ´ÃÇÏ´Ã
2016-12   5876   ¼öÇÊó·³
2010-03   14378   ³ª¸§´ë·Î
2016-01   3898   Æ÷Ä«
2014-10   20222   ±è°Ç¿ì
2023-07   1702   ½Öcpu
2010-03   8014   dongx3
2019-05   5414   ¾Ö´Ï¾Ç
2010-04   15347   ±è°Ç¿ì
2016-02   20622   ¸®¿À
2020-07   4535   ¼­¿ï¿©¿ì
2021-12   1496   chanelacy
2021-12   1787   startserver
2014-11   7606   ±èȲÁß
2010-05   9739   °æ¹ÚÇѽùÎ