얼마전 베터리를 교체 했는데 계속 차징이 반복을 합니다. 관련 로그 입니다.
제발 좀 봐주십시요 ㅠㅠ
ID = 3005
SEQUENCE NUMBER = 23737
TIME = 24-11-2014 15:02:05
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-24,15:02:05 95888 Seconds
ID = 3004
SEQUENCE NUMBER = 23736
TIME = 24-11-2014 14:15:52
LOCALIZED MESSAGE = Controller ID: 0 Battery properties changed
ID = 3003
SEQUENCE NUMBER = 23735
TIME = 24-11-2014 14:15:32
LOCALIZED MESSAGE = Controller ID: 0 Battery properties changed
ID = 3002
SEQUENCE NUMBER = 23734
TIME = 24-11-2014 14:13:23
LOCALIZED MESSAGE = Controller ID: 0 Battery properties changed
ID = 3001
SEQUENCE NUMBER = 23733
TIME = 24-11-2014 14:07:47
LOCALIZED MESSAGE = Controller ID: 0 Battery started charging
ID = 3000
TIME = 24-11-2014 14:07:04
LOCALIZED MESSAGE = Successful log on to the server User: ALKO9KO060015, Client: 169.254.95.120, Access Mode: Full, Client Time: 2014-11-24,14:07:04
ID = 2999
SEQUENCE NUMBER = 23732
TIME = 24-11-2014 14:06:42
LOCALIZED MESSAGE = Controller ID: 0 Battery relearn pending: Battery is under charge
ID = 2998
TIME = 24-11-2014 14:06:30
LOCALIZED MESSAGE = Successful log out from the server User: ALKO9KO060015, Client: 169.254.95.120, Client Time: 2014-11-24,14:06:30
ID = 2997
SEQUENCE NUMBER = 23731
TIME = 24-11-2014 14:02:05
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-24,14:02:05 92288 Seconds
ID = 2996
TIME = 24-11-2014 14:01:49
LOCALIZED MESSAGE = Successful log on to the server User: ALKO9KO060015, Client: 169.254.95.120, Access Mode: Full, Client Time: 2014-11-24,14:01:49
ID = 2995
SEQUENCE NUMBER = 23730
TIME = 24-11-2014 13:02:05
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-24,13:02:05 88689 Seconds
ID = 2994
SEQUENCE NUMBER = 23729
TIME = 24-11-2014 12:02:05
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-24,12:02:05 85089 Seconds
ID = 2993
SEQUENCE NUMBER = 23728
TIME = 24-11-2014 11:02:05
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-24,11:02:05 81489 Seconds
ID = 2992
SEQUENCE NUMBER = 23727
TIME = 24-11-2014 10:02:05
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-24,10:02:05 77889 Seconds
ID = 2991
SEQUENCE NUMBER = 23726
TIME = 24-11-2014 09:02:05
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-24,09:02:05 74289 Seconds
ID = 2990
SEQUENCE NUMBER = 23725
TIME = 24-11-2014 08:02:05
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-24,08:02:05 70689 Seconds
ID = 2989
SEQUENCE NUMBER = 23724
TIME = 24-11-2014 07:02:05
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-24,07:02:05 67089 Seconds
ID = 2988
SEQUENCE NUMBER = 23723
TIME = 24-11-2014 06:02:05
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-24,06:02:05 63489 Seconds
ID = 2987
SEQUENCE NUMBER = 23722
TIME = 24-11-2014 05:02:05
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-24,05:02:05 59889 Seconds
ID = 2986
SEQUENCE NUMBER = 23721
TIME = 24-11-2014 04:02:05
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-24,04:02:05 56289 Seconds
ID = 2985
SEQUENCE NUMBER = 23720
TIME = 24-11-2014 03:58:56
LOCALIZED MESSAGE = Controller ID: 0 Battery charge complete
ID = 2984
SEQUENCE NUMBER = 23719
TIME = 24-11-2014 03:32:56
LOCALIZED MESSAGE = Controller ID: 0 Policy change on VD: 1 Previous = Current Write Policy: Write Through Current = Current Write Policy: Write Back
ID = 2983
SEQUENCE NUMBER = 23718
TIME = 24-11-2014 03:32:56
LOCALIZED MESSAGE = Controller ID: 0 Policy change on VD: 0 Previous = Current Write Policy: Write Through Current = Current Write Policy: Write Back
ID = 2982
SEQUENCE NUMBER = 23717
TIME = 24-11-2014 03:32:56
LOCALIZED MESSAGE = Controller ID: 0 BBU enabled; changing WT logical drives to WB
ID = 2981
SEQUENCE NUMBER = 23716
TIME = 24-11-2014 03:02:05
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-24,03:02:05 52689 Seconds
ID = 2980
SEQUENCE NUMBER = 23715
TIME = 24-11-2014 02:02:05
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-24,02:02:05 49089 Seconds
ID = 2979
SEQUENCE NUMBER = 23714
TIME = 24-11-2014 01:55:25
LOCALIZED MESSAGE = Controller ID: 0 Battery started charging
ID = 2978
SEQUENCE NUMBER = 23713
TIME = 24-11-2014 01:54:20
LOCALIZED MESSAGE = Controller ID: 0 Battery relearn completed
ID = 2977
SEQUENCE NUMBER = 23712
TIME = 24-11-2014 01:02:04
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-24,01:02:04 45489 Seconds
ID = 2976
SEQUENCE NUMBER = 23711
TIME = 24-11-2014 00:02:04
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-24,00:02:04 41889 Seconds
ID = 2975
SEQUENCE NUMBER = 23710
TIME = 23-11-2014 23:09:40
LOCALIZED MESSAGE = Controller ID: 0 Battery relearn in progress
ID = 2974
SEQUENCE NUMBER = 23709
TIME = 23-11-2014 23:09:40
LOCALIZED MESSAGE = Controller ID: 0 Battery is discharging
ID = 2973
SEQUENCE NUMBER = 23708
TIME = 23-11-2014 23:08:36
LOCALIZED MESSAGE = Controller ID: 0 Battery relearn started
ID = 2972
SEQUENCE NUMBER = 23707
TIME = 23-11-2014 23:08:35
LOCALIZED MESSAGE = Controller ID: 0 Battery charge complete
ID = 2971
SEQUENCE NUMBER = 23706
TIME = 23-11-2014 23:02:04
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-23,23:02:04 38289 Seconds
ID = 2970
SEQUENCE NUMBER = 23705
TIME = 23-11-2014 22:02:04
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-23,22:02:04 34689 Seconds
ID = 2969
SEQUENCE NUMBER = 23704
TIME = 23-11-2014 21:21:20
LOCALIZED MESSAGE = Controller ID: 0 Battery started charging
ID = 2968
SEQUENCE NUMBER = 23703
TIME = 23-11-2014 21:20:15
LOCALIZED MESSAGE = Controller ID: 0 Battery relearn pending: Battery is under charge
ID = 2967
SEQUENCE NUMBER = 23702
TIME = 23-11-2014 21:20:15
LOCALIZED MESSAGE = Controller ID: 0 Battery charge complete
ID = 2966
SEQUENCE NUMBER = 23701
TIME = 23-11-2014 21:02:04
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-23,21:02:04 31089 Seconds
ID = 2965
SEQUENCE NUMBER = 23700
TIME = 23-11-2014 20:02:04
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-23,20:02:04 27489 Seconds
ID = 2964
SEQUENCE NUMBER = 23699
TIME = 23-11-2014 19:42:45
LOCALIZED MESSAGE = Controller ID: 0 Battery requires reconditioning; please initiate a LEARN cycle
ID = 2963
SEQUENCE NUMBER = 23697
TIME = 23-11-2014 19:15:40
LOCALIZED MESSAGE = Controller ID: 0 Battery started charging
ID = 2962
SEQUENCE NUMBER = 23696
TIME = 23-11-2014 19:14:35
LOCALIZED MESSAGE = Controller ID: 0 Battery relearn completed
ID = 2961
SEQUENCE NUMBER = 23695
TIME = 23-11-2014 19:02:04
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-23,19:02:04 23889 Seconds
ID = 2960
SEQUENCE NUMBER = 23694
TIME = 23-11-2014 18:02:04
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-23,18:02:04 20289 Seconds
ID = 2959
SEQUENCE NUMBER = 23693
TIME = 23-11-2014 17:02:04
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-23,17:02:04 16690 Seconds
ID = 2958
SEQUENCE NUMBER = 23692
TIME = 23-11-2014 16:28:49
LOCALIZED MESSAGE = Controller ID: 0 Battery relearn in progress
ID = 2957
SEQUENCE NUMBER = 23691
TIME = 23-11-2014 16:28:49
LOCALIZED MESSAGE = Controller ID: 0 Battery is discharging
ID = 2956
SEQUENCE NUMBER = 23690
TIME = 23-11-2014 16:27:48
LOCALIZED MESSAGE = Controller ID: 0 Battery relearn started
ID = 2955
SEQUENCE NUMBER = 23689
TIME = 23-11-2014 16:27:34
LOCALIZED MESSAGE = Controller ID: 0 Battery charge complete
ID = 2954
SEQUENCE NUMBER = 23688
TIME = 23-11-2014 16:02:04
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-23,16:02:04 13090 Seconds
ID = 2953
SEQUENCE NUMBER = 23687
TIME = 23-11-2014 15:02:04
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-23,15:02:04 9490 Seconds
ID = 2952
SEQUENCE NUMBER = 23686
TIME = 23-11-2014 14:02:04
LOCALIZED MESSAGE = Controller ID: 0 Time established since power on: Time 2014-11-23,14:02:04 5890 Seconds
¼¾¼ ¹®Á¦ Àϼö Àֳ׿ä..
raidÄ«µå ±³Ã¼Çغ¸½ÉÀÌ ÁÁÀ»µí ÇÕ´Ï´ç
BBU ÀÚü¸¦ ÀνÄÇÏÁö ¸øÇÏ´Â ½Ã±â°¡ Á¸À縦 ÇÕ´Ï´Ù.
"Battery properties changed
Battery relearn pending"
ÀνÄÀÌ ¹Ýº¹ÀûÀ¸·Î ¹øº¹ÀÌ µÇ´Â °Í °°½À´Ï´Ù.
ÃæÀüÀº 2½Ã°£ Á¤µµ °É¸®´Ï
¹èÅ͸® ¹®Á¦°¡ ¾Æ´Ï¶ó ¼¾¼ÀÇ ¹®Á¦ÀÏ °Í °°½À´Ï´Ù.
Ȥ½Ã ¸ðµ¨ÀÌ ¹«¾ùÀÎÁö ¾Ë ¼ö ÀÖ´ÂÁö¿ä?