예전에 알려주신 hdsentinel을 받아서(free/linux 64bit) 실행하는데 별다른 메시지를 얻지 못했습니다
# ./hdsentinel-017-x64 -verbose Hard Disk Sentinel for LINUX console 0.17x64.8556 (c) 2017 ****@**********.com Start with -r [reportfile] to save data to report, -h for help Examining hard disk configuration ... Disk device: /dev/sda Disk device: /dev/sdb HDD Device 0: /dev/sda HDD Model ID : Samsung SSD 850 EVO 500GB HDD Serial No: -- HDD Revision : EMT02B6Q HDD Size : 476940 MB Interface : LSI RAID #0/0 [8-0] Temperature : 27 °C Highest Temp.: 46 °C Health : 100 % Performance : 100 % Power on time: 998 days, 6 hours Est. lifetime: more than 826 days Total written: 4.08 TB The status of the solid state disk is PERFECT. Problematic or weak sectors were not found. No actions needed. HDD Device 1: /dev/sda HDD Model ID : Samsung SSD 850 EVO 500GB HDD Serial No: -- HDD Revision : EMT02B6Q HDD Size : 476940 MB Interface : LSI RAID #0/1 [8-0] Temperature : 30 °C Highest Temp.: 47 °C Health : 100 % Performance : 100 % Power on time: 998 days, 6 hours Est. lifetime: more than 826 days Total written: 4.06 TB The status of the solid state disk is PERFECT. Problematic or weak sectors were not found. No actions needed. HDD Device 2: HDD Model ID : DELL PERC H730 Mini HDD Serial No: ? HDD Revision : 4.27 HDD Size : 4576255 MB Interface : SCSI Temperature : Unknown °C Highest Temp.: Unknown °C Health : Unknown % Performance : Unknown % Power on time: Est. lifetime: |
그래서
smartctl로 옵션을 줘서 하니 개별로 나오는데, 다른 하드들은 0이나 1 정도 인데 얘만 유독 높게 잡히네요.
검색을 해봐도 해당 에러에 대한 내용이 자세히 나온걸 발견하지 못했는데
매체가 아닌 에러니까.. 복구가능한 에러라서 무시해도 되는걸지 아니면 하드교체를 염두에 두어야 할지 궁금합니다.
# smartctl -a /dev/sda -d megaraid,04 smartctl 6.5 2016-05-07 r4318 [x86_64-linux-3.10.0-957.5.1.el7.x86_64] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Vendor: SEAGATE Product: ST1200MM0088 Revision: TT31 Compliance: SPC-4 User Capacity: 1,200,243,695,616 bytes [1.20 TB] Logical block size: 512 bytes Formatted with type 2 protection LU is fully provisioned Rotation Rate: 10000 rpm Form Factor: 2.5 inches Logical Unit id: 0x5000c50084fb0aa3 Serial number: -- Device type: disk Transport protocol: SAS (SPL-3) Local Time is: Fri Mar 15 10:37:02 2019 KST SMART support is: Available - device has SMART capability. SMART support is: Enabled Temperature Warning: Disabled or Not Supported === START OF READ SMART DATA SECTION === SMART Health Status: OK Current Drive Temperature: 30 C Drive Trip Temperature: 60 C Manufactured in week 04 of year 2016 Specified cycle count over device lifetime: 10000 Accumulated start-stop cycles: 33 Specified load-unload count over device lifetime: 300000 Accumulated load-unload cycles: 1778 Elements in grown defect list: 0 Vendor (Seagate) cache information Blocks sent to initiator = 3091726124 Blocks received from initiator = 2959663898 Blocks read from cache and sent to initiator = 2584128793 Number of read and write commands whose size <= segment size = 48148692 Number of read and write commands whose size > segment size = 17875 Vendor (Seagate/Hitachi) factory information number of hours powered up = 21516.63 number of minutes until next internal SMART test = 19 Error counter log: Errors Corrected by Total Correction Gigabytes Total ECC rereads/ errors algorithm processed uncorrected fast | delayed rewrites corrected invocations [10^9 bytes] errors read: 149275407 0 0 149275407 0 6859.375 0 write: 0 0 1 1 1 10498.622 0 verify: 2881634149 1 0 2881634150 1 139918.217 0 Non-medium error count: 731 No self-tests have been logged |
그리고 다른 서버에 물렸던 하드 2개는 SMART 정보가
SMART Self-test log Num Test Status segment LifeTime LBA_first_err [SK ASC ASQ] Description number (hours) # 1 Background short Completed 80 6 - [- - -] # 2 Background short Completed 80 5 - [- - -] # 3 Reserved(7) Completed 64 5 - [- - -] # 4 Background short Completed 80 3 - [- - -] Long (extended) Self Test duration: 7630 seconds [127.2 minutes] |
위와 같이 뜨는데 나머지 하드는 뜨질 않네요.. patrol 설정과는 별개로 DELL PERC H710P mini 쪽에
smart long test를 설정 가능한 부분이 있는지 질문 드립니다.
½Ã°ÔÀÌÆ® 1.2TB Â¥¸®´Â ¿¡·¯°¡ Ä«¿îÆ®°¡ µÇ½Å´Ù°í Çߴµ¥
º¸Åë ECC /re-write /re-command °°Àº °Í¿¡¼ ¿¡·¯°¡ ³ª¸é SSD µð¹ÙÀ̽º ÀÚüº¸´Ù ÄÉÀÌºí¸µ¿¡ ¹®Á¦°¡ ÀÖÀ»¼ö ÀÖ½À´Ï´Ù..
ÄÉÀ̺íÀ̳ª ¹éÇ÷¹Àο¡ ¹®Á¦°¡ ÀÖ¾î ½ÅÈ£°¡ Àç´ë·Î ¸ø°¡°í ÀÚ²Ù Àç½ÅÈ£¸¦ º¸³»¼ µ¿ÀÛÇÑ´Ù´Â À̾߱âÀÔ´Ï´Ù..
¿¡·¯ Ä«¿îÆ® µÇ´Â SSD¸¦ °°Àº ½Ã½ºÅÛÀÇ ´Ù¸¥ µð½ºÅ©º£À̳ª ´Ù¸¥ ½Ã½ºÅÛ¿¡ ²Å¾Æ¼ ´Ù½Ã äũÇغ¸¼¼¿ä..
¼¹ö´Â ¿î¿µÁßÀÌ°í µ¥ÀÌÅ͸¦ ¹é¾÷ÇÏ´Â °ÍÀº ½±Áö ¾ÊÁö¸¸ äũ´Â Çغ¸¼Å¾ß ÇÒ µíÇÕ´Ï´Ù..
ÀÏ´ÜÀº °ªÀÌ Áõ°¡ÇÏ´ÂÁö Á» ÁöÄѺÁ¾ß °Ú³×¿ä.
´Ù¸¥ ½Ã½ºÅÛ¿¡ ´Þ·ÁÀÖ´ø ÇϵåµéÀ̶ó, ´Ù¸¥ ½Ã½ºÅÛ¿¡¼ ´©ÀûµÈ °ªÀϼöµµ ÀÖÀ»Å״ϱî¿ä.
¸Å¹ø ¸®Çà °¨»çµå¸³´Ï´Ù.
»ç¿ëÀÚµµ °ÅÀÇ ¾ø´Â »ï¹Ù ½ºÅ丮Áö¿ëÀε¥µµ ºÒ±¸ÇÏ°í ±×»õ 2 ¿Ã¶ú³×¿ä
Non-medium error count: 733
ÇöÀç ¹éÇ÷¹ÀÎÀ̳ª ÄÉÀÌºí ¹®Á¦·Î »ý°¢À» ÇÏ°í ´ëó¸¦ °±¸ÇØ¾ß ÇÒ »óȲÀεí ÇÕ´Ï´Ù.
¸Å¹ø Á¶¾ð ÇØÁּż °¨»çÇÕ´Ï´Ù.
SAS 10k 1.2T 2,3,4,5,6,7 ¹ø¿¡ RAID6ÀÌ°í À̳༮Áß¿¡ 4¹øÀÌ Á» ºÒ¾ÈºÒ¾ÈÇϳ׿ä.
»·ÇÑ À̾߱âÀÌÁö¸¸ µ¥ÀÌÅÍ°¡ ÀçÀÏ Áß¿äÇϱ⿡ ¹é¾÷¸¸ÀÌ »ì±æÀÔ´Ï´Ù..
·¹À̵尡 ½ÅÀÌ ¸¸µç ÀåÄ¡´Â ¾Æ´Ï±â¿¡ »ç¶÷ÀÌ ¸¸µé¾ú±â¿¡ ¾ðÁ¨°¡´Â °íÀåÀÌ ³³´Ï´Ù..
µð½ºÅ© 1°³¸¸ °íÀ峯¼öµµ
µð½ºÅ© ¿©·¯°³°¡ ÇѲ¨¹ø¿¡ °íÀ峯¼öµµ
·¹À̵å Ä«µå°¡ °íÀ峯¼öµµ
¼¹ö Àüü°¡ Àۻ쳯 ¼öµµ ÀÖ½À´Ï´Ù..
µð½ºÅ© 1°³¸¸ °íÀ峯¼öµµ
µð½ºÅ© ¿©·¯°³°¡ ÇѲ¨¹ø¿¡ °íÀ峯¼öµµ
>> RAID6¿¡ 6°³ HDD´Ï±î ¼³¸¶.. ¶ó´Â ´À³¦À¸·Î ¹öƼ·Á°í ÇÕ´Ï´Ù.
·¹À̵å Ä«µå°¡ °íÀ峯¼öµµ
¼¹ö Àüü°¡ Àۻ쳯 ¼öµµ ÀÖ½À´Ï´Ù..
>> ³²Àº R730ÀÌ ÀûÃâ¼ö¼úÀ» ´çÇÏ¸é µË´Ï´Ù.....
¹é¾÷Á¤Ã¥Àº ¶Ç ¾î¶»°Ô ¼¼¿ö¾ß Çϳª °í¹ÎÁßÀÔ´Ï´Ù.
Àüü¹é¾÷À¸·Î 2°³ Çϵ忡´Ù°¡ µû·Îµû·Î ¸ÅÀϸÅÀÏ ¹é¾÷À» ÇÏ¸é ¼ÓÆíÇÒ°Å °°Àºµ¥ ¸»ÀÌÁÒ.