미크로틱 2대로,
capsman/Controller (Hap) + AP (Audience)로 구성하려 합니다.
하기와 같이 구성을 하였는데, caps-man에서 조회해 보면 해당 AP와 연결이 되지 않고 있습니다.
참고로 caps-man + cap 간에 L3 (IP)로 연결해야 되는 상황 입니다.
caps-man ether1 <-> cap ether1 공인 IP로 핑은 잘 되는 상태 입니다.
아시는 분의 조언 부탁 드려 봅니다. 꾸벅 ~.~
[nhsung@ROUTER1] /caps-man interface> print
Flags: M - master, D - dynamic, B - bound, X - disabled, I - inactive, R - running
# NAME RADIO-MAC MASTER-INTERFACE
감사합니다.
======== 미크로틱 설정 내역 ===============
[ CAPSMAN ]
....
/caps-man datapath
add bridge=bridge-local name=dp-full
/caps-man security
add authentication-types=wpa-psk,wpa2-psk encryption=aes-ccm name=security1 passphrase=qlsfkeps
/caps-man configuration
add country="korea republic3" datapath=dp-full name=Master-CFG security=security1 ssid=CAPsMAN
add country="korea republic3" datapath=dp-full name=Slave-CFG security=security1 ssid=Guest
/caps-man manager
set enabled=yes upgrade-policy=require-same-version
/caps-man provisioning
add action=create-dynamic-enabled master-configuration=Master-CFG slave-configurations=Slave-CFG
....
[CAP]
...
/caps-man configuration
add channel.band=2ghz-b/g/n channel.control-channel-width=20mhz channel.extension-channel=XX comment=defconf \
datapath.client-to-client-forwarding=yes datapath.local-forwarding=yes distance=indoors installation=indoor name=\
cfg-2ghz ssid=MikroTikD15882-2
add channel.band=5ghz-a/n/ac channel.control-channel-width=20mhz channel.extension-channel=XXXX comment=defconf \
datapath.client-to-client-forwarding=yes datapath.local-forwarding=yes distance=indoors installation=indoor name=\
cfg-5ghz-ac ssid=MikroTikD15882-5
add channel.band=5ghz-a/n channel.control-channel-width=20mhz channel.extension-channel=XX comment=defconf \
datapath.client-to-client-forwarding=yes datapath.local-forwarding=yes distance=indoors installation=indoor name=\
cfg-5ghz-an ssid=MikroTikD15882-5
/caps-man manager
set enabled=yes
/caps-man manager interface
set [ find default=yes ] forbid=yes
add comment=defconf disabled=no
/caps-man provisioning
add action=create-dynamic-enabled comment=defconf hw-supported-modes=gn master-configuration=cfg-2ghz name-format=\
prefix-identity name-prefix=2ghz
add action=create-dynamic-enabled comment=defconf hw-supported-modes=ac master-configuration=cfg-5ghz-ac name-format=\
prefix-identity name-prefix=5ghz-ac
add action=create-dynamic-enabled comment=defconf hw-supported-modes=an master-configuration=cfg-5ghz-an name-format=\
prefix-identity name-prefix=5ghz-an
....
공장초기상태 또는 미크로틱 앱으로 기본 설정을 한 Audience에 CAP모드의 장비를(가능하면 리셋버튼으로 진입) 직결하거나 스위치 통해 연결하면 잘 됩니다.
저의 경우는 L3로 연동해야 되는 상황 입니다. ~.~
생각으로는 미크로틱 장비간에 VPN Tunnel (site-to-site)을 만들고, 여기에 CAPSMAN을 L2로 연결해도 될 거 같기는 한데...
Troubleshooting을 어케 시작 해야 될지 및 설정에 문제점이 없는 지 궁금해서요
구글링에도 잘 안 나오네요 ~.~
해당 내역을 반영했지만, 문제점이 해결되지 않았네요 ~.~
혹시 L3(IP)로 CapsMan / Cap 연결 성공하신 분 있으시면, 해당 부분 설정 공유 부탁 드려 봅니다. 꾸벅..
1. 5GHz 백홀 용도의 2번째 대역을 무선랜 AP로 사용이 가능할런지요 ?
2. 백홀 용도로 주파수 고정 및 제약 사항이 있는 건지요 ?