HP Smart storage Administraor 에서
263 Smart Array P410i in Embedded Slot has one or cache module backup power sources that have failed. Caching operations such as Expansion, Extension, and Migration are temporarily suspended until the backup power sources are replaced. Please consult the user guide to identify and replace the failed components.
826 The cache for Smart Array P410i in Embedded Slot has been disabled because the backup power source attached to the cache module has failed to charge.
341 500 GB SAS HDD at Port 1I : Box 1 : Bay 2 is predicted to fail soon.
이런식으로 오류가 뜨는데요
혹시 해결할려면 어떤식으로 해야할까요?..
이걸 처음 다루다보니 그냥 새로운 SAS하드 넣어야할지 잘 모르겠네요
·¹À̵å ÄÜÆ®·Ñ·¯°¡ °íÀåÀÌ ÀÖ°í¿ä.. (ij½¬ ¸ðµâ ȤÀº BBU ¿¡ ¹®Á¦°¡ ÀÖ´Â µí)
ù¹ø° ¹Ú½º µÎ¹ø° Çϵå 500±â°¡ Â¥¸®°¡ ¹èµå°¡ Áõ°¡ÇÏ¸é¼ Á» ÀÖÀ¸¸é Á×À» °Í °°´Ù°í ÇÕ´Ï´Ù..
¿ì¼± µ¥ÀÌÅÍ º¸À϶§ »¡¸® ¹é¾÷À» ¶ß´Â °ÍÀ» ±ÇÇص帳´Ï´Ù..
BBU°¡ Á×¾ú±â ¶§¹®¿¡ RAID5/6¿¡¼ CACHE ¼³Á¤ Ç߾ ¹«½ÃÇÏ°Ô µË´Ï´Ù. ¾öû ´À¸±°Ì´Ï´Ù
Ȥ½Ã ÇÏµå ±³Ã¼ÇÒ¶§ ¶È°°Àº Á¦Ç°À¸·Î ÇؾßÇϳª¿ä?
¾Æ´Ï¸é Ÿ»çÁ¦Ç° SAS 500GB·Î Çصµ µÉ±î¿ä?
µ¿ÀÏ Á¦Ç°ÀÌ ¹°·® ã±â°¡ Èûµé °Í °°¾Æº¸ÀÔ´Ï´Ù..
ÃßõÇϳĸ¦ ¹°À¸½Ã¸é µ¿ÀÏ HP ÆÄÆ®¸é ÃßõÇÕ´Ï´Ù.
Ÿ»ç Á¦Ç°ÀÌ¸é ºñÃßõ ÇÕ´Ï´Ù¸¸ ¾î°µç µ¹¾Æ´Â °¥°Ì´Ï´Ù
»ç¿ëÇϽô HP ¸ðµ¨¿¡ ¸Â´Â Á¤Ç° ÆÄÃ÷¸¸ »ç¿ëÇØ¾ß ÇÕ´Ï´Ù..
±¸¸ÅÇϽŠ°÷¿¡ ¹®ÀÇÇϽôøÁö HP ¸®¼¿·¯¸¦ ã¾Æ º¸½Ã´øÁö
±¸¸Å¶õ¿¡ Æ÷ÀÎÆ® ¾²¸é¼ Á¦Ç° ±¸ÇÑ´Ù°í ¿Ã·Á º¸½Ã´øÁö Çغ¸¼¼¿ä..
¹èÅ͸® ¸ÕÀú ±³Ã¼ÀÛ¾÷ÇØ¾ß ÇÕ´Ï´Ù.
2. HP 500GB SAS Á¤Ç°À¸·Î ±³Ã¼ÇØ¾ß ÇÕ´Ï´Ù.
Á¤»óÁ¾·á ¾ÈÇÏ°í Àü¿ø½ºÀ§Ä¡¸¦ ²ô°Å³ª Á¤ÀüÀÌ µÇ¸é ³ôÀº È®·ü·Î Logical Drive2 ÀÇ µ¥ÀÌÅÍ°¡ ¸Á½ÇµÉ ¼ö ÀÖ½À´Ï´Ù.
¹èÅ͸® ¼ö¹èÇϽðí, Á¤»óÀûÀ¸·Î Á¾·á½ÃŲ ÈÄ ¹èÅ͸®¸¦ ±³Ã¼ÇϽñ⠹ٶø´Ï´Ù.
2. Raid-1À¸·Î ¹¿© ÀÖ´Â µð½ºÅ© Áß ÇϳªÀÇ »óÅ°¡ ÁÁÁö ¾Ê½À´Ï´Ù.
º£µå¼½ÅÍ°¡ ÀǽɵǸç, Áö±Ýµµ ¼Óµµ°¡ ¸¹ÀÌ ´Ê¾îÁ³À» °ÍÀ¸·Î ¿¹»óµË´Ï´Ù.
ÃÖ´ëÇÑ ºü¸¥ ½ÃÀÏ ³»¿¡ ±³Ã¼¸¦ ÇØ¾ß ÇÕ´Ï´Ù.
3. ±âÁ¸ µð½ºÅ©´Â HP Á¦Ç°À¸·Î º¸À̸ç, HP Á¤Ç°ÆÄÃ÷¶ó¸é ¸ðµÎ °°Àº ÆÄÆ®³Ñ¹ö¸¦ °¡Áý´Ï´Ù.
Áï, ¿ø·¡ µð½ºÅ©´Â ½Ã°ÔÀÌÆ®Àε¥ »õ·Î ±¸¸ÅÇÑ µð½ºÅ©°¡ WD Á¦Ç°ÀÌ¶óµµ HP¿¡¼ °ø±ÞÇÑ Á¤Ç°À̶ó¸é ¾Æ¹«·± ¹®Á¦°¡ ¾ø½À´Ï´Ù.
4. HP Á¤Ç° µð½ºÅ©´Â Á». ¸¹ÀÌ. ºñ½Ô´Ï´Ù....
ÇÏÁö¸¸ ȸ»çµ·À» ¾²½Ã´Â °Å¶ó¸é ´ç¿¬È÷ Á¤Ç° ¾²½Ã´Â°Ô ¿Ç½À´Ï´Ù.