/112;드햇 7.9 160;사용 1077;니다.
보드에 1109;착.108; SATA 포트나 1064;텔 /112;1060;드 카드에 연결.108; 디스크 SMART 1221;보lj16; /112;1060;드 구성과 관계없1060;
smartctl 160;커멘드/196; 확1064; 할 수 1080;lj16;데요.
LSI 9217 (SAS2308)에 연결.108; 디스크lj16; /112;1060;드 구성1204;에lj16;160;
smartctl 160;-a /dev/sda
smartctl 160;-a /dev/sdb
smartctl 160;-a /dev/sdc
1004;/196; 각각 결과가 출/141; .121;니다.
Ȣ16;1648;만 /dev/sdb 와 /dev/sdc 를 /112;1060;드 구성후에lj16;
# smartctl --scan 출/141;에서 아래 처/100; /dev/sdb 와 /dev/sdc 가 Ȣ16;나1032; 볼륨 구성.104;Ǻ12; /dev/sdb 가 .121;니다.
/dev/sda -d scsi # /dev/sda, SCSI device
/dev/sdb -d scsi # /dev/sdb, SCSI device
# smartctl 160;-a /dev/sda 160;lj16; /112;1060;드 구성에 포함.104;1648; 않1008; 디스크1060;므/196; 1060;1204;과 ᇼ1;1068;Ȣ16;,172; 출/141; .104;1648;만160;
# smartctl 160;-a /dev/sdb 160;lj16; 아래 처/100; SMART 1221;보가 나오1648; 않습니다.
# smartctl 160;-a /dev/sdb
smartctl 7.0 2018-12-30 r4883 [x86_64-linux-3.10.0-1160.el7.x86_64] (local build)
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Vendor: 160; 160; 160; 160; 160; 160; 160; LSI
Product: 160; 160; 160; 160; 160; 160; 160;Logical Volume
Revision: 160; 160; 160; 160; 160; 160; 3000
Compliance: 160; 160; 160; 160; 160; SPC-4
User Capacity: 160; 160; 160; 160;3,997,997,989,888 bytes [3.99 TB]
Logical block size: 160; 512 bytes
Physical block size: 160;4096 bytes
Logical Unit id: 160; 160; 160;0x600508e00000000033f0482e3dc8b708
Device type: 160; 160; 160; 160; 160;disk
Local Time is: 160; 160; 160; 160;Fri Jun 10 05:51:34 2022 EDT
SMART support is: 160; 160; Unavailable - device lacks SMART capability.
=== START OF READ SMART DATA SECTION ===
Current Drive Temperature: 160; 160; 0 C
Drive Trip Temperature: 160; 160; 160; 160;0 C
Error Counter logging not supported
Device does not support Self Test logging
보드1032; SATA 에 1064;텔/112;1060;드 구성후 아래 처/100;160;
smartctl --scan 에서 /dev/bus/6 -d megaraid_disk_12 과 /dev/bus/6 -d megaraid_disk_13 가 나오며
# smartctl --scan
/dev/sda -d scsi # /dev/sda, SCSI device
/dev/sdb -d scsi # /dev/sdb, SCSI device
/dev/bus/6 -d megaraid_disk_12
/dev/bus/6 -d megaraid_disk_13
# smartctl -a /dev/bus/6 -d megaraid_disk_12
# smartctl -a /dev/bus/6 -d megaraid_disk_13
1004;/196; SMART 1221;보가 나Ꮢ1;니다.
LSI 9217 (CTRL-C) /196; 1217;속해서 설1221; 메1060;1648;에서lj16; SMART를 enable Ȣ16;lj16; Ꮢ1;션1008; 1316;1116; Ȣ16;1648; 않습니다.
1064;텔/112;1060;드 카드lj16; .104;lj16;데 LSI9217 1060; 않.104;lj16; ,163;1004;/196; 보아서 HBA 카드에 따라서 않.104;lj16; ,163; 처/100; 보1077;니다.
LSI9217 (SAS2308)lj16; /112;1060;드 볼륨1008; 160;SMART가 처리.104;1648; 않나요?
만1068; 1060;,163;1060; 않.104;lj16; ,163;1060;면 Ȣ16;드디스크 손상 여ǥ12;를 Ǻ12;떻,172; 판단 합니까 ?
디스크가 완1204;7176; 고1109;나기 1204;에 오류를 ,160;토해서 교체할 0169;법1060; 1080;습니까 ?
/112;1060;드 볼륨1012; 해1228; 해서 확1064; Ȣ16;면 .104;1648;만 그러면 /112;1060;드 볼륨 데1060;터가 손상.112; 텐데요.
LSI 9217 (SAS2308) 에 연결.108; 디스크를 /112;1060;드/196; 구성 했1012;ǐ12; SMART info 가 나오도/197; Ȣ16;/140;면 Ǻ12;떻,172; 해야 Ȣ16;나요
/112;드햇에서1032; HBA 카드 1221;보lj16;160;
# lspci | grep SAS
03:00.0 Serial Attached SCSI controller: Broadcom / LSI SAS2308 PCI-Express Fusion-MPT SAS-2 (rev 05)
HBA firmware 1221;보lj16;160;
/112;1060;드 볼륨 생성시"Pred Fail" 항목1060; No 1004;/196; 나오며 grade-out 1004;/196; .104;Ǻ12; Yes를 선택Ȣ16;1648; 못Ȣ16;,172; .104;Ǻ12; 1080;Ǻ12;요.
HBA firmware 버1204; ǐ12;문 1064;가요?
가1109; 최신1064; P20 버1204;1004;/196; flash 한 타드에 1109;착.108; 디스크1032; /112;1060;드 볼륨도 SMART가 나오1648; 않습니다.
고수님들 1312;Ǻ16;1012; ǥ12;ᓠ1; 드립니다.
HBA Ä«µå°¡ ·¹ÀÌµå º¼·ýÀÇ SMART¸¦ Áö¿ø ÇÏÁö ¾Ê´Â °ÍÀ¸·Î º¸ÀÔ´Ï´Ù.
LSI´Â ¾Æ½Ã°ÚÁö¸¸ OEM À§ÁÖÀÎÁö¶ó ÀÎÅÚº¸µå¸é ÀÎÅÚ¿¡ OEM µÈ Ä«µå¸¸ ½á¾ß ÇÒ ¼öµµ ÀÖ½À´Ï´Ù..
´Ù¸¥ ¼¹ö º¸µå³ª ÀÏ¹Ý PC¿¡ ¼³Ä¡ÇغÁ¼ ºñ±³ÇغÁ¾ß ÇÒ µíÇÕ´Ï´Ù..
Áý¿¡¼ ÀÌ°ÍÀú°Í Å×½ºÆ® ¿ëµµ·Î »ç¿ëÇÏ´Â °ÍÀ̱¸¿ä.
»ç¹«½Ç ¼¹ö¿¡ ÀåÂøÇØ ³õÀº µð½ºÅ©µéÀÇ SMART¸¦ È®ÀÎ ÇÏ·Á°í ... Å×½ºÆ® Áß ÀÔ´Ï´Ù.
ÀÎÅÚº¸µå¿¡µµ ÀÎÅÚHBA Ä«µå¸¦ LSI firmware·Î flash Çسõ¾Ò´Âµ¥ ... SMART´Â ³ª¿ÀÁö ¾Ê¾Æ¿ä.
±×³É ÀÎÅÚ HBAÀ¸·Î ±¸¼ºÇßÀ¸¸é SMART °¡ ³ª¿Ã ¼öµµ ÀÖÀ»ÅÙµ¥ .. LSI firmware°¡ ´õ ÃֽŠ¹öÀüÀ̶ó¼ Çߴµ¥ .. ¾µµ¥¾ø´Â ¢À» Çß³ª º¾´Ï´Ù.
Ȥ½Ã HBA´Â ¾ÊµÇ°í RAID Ä«µå¸¸ SMART°¡ ³ª¿À´Â °É ±î¿ä?
¾ÆÁÖ ¿À·¡µÈ $10 Â¥¸® "Intel RAID Controller Low Profile Card (SRCSASLS4I)" À¸·Î ¿¬°áÇϸé SMART°¡ ³ª¿É´Ï´Ù...
HBA´Â ¶ó¼ ¾ÊµÇ´Â °Å¸é LSI firmware·Î flash Ç߱⠶§¹®¿¡ SMART°¡ ³ª¿ÀÁö ¾Ê´Â °ÍÀº ¾Æ´Ñ°Í °°¾Æ¿ä.
DELL T7610 ¿Âº¸µå SASÆ÷Æ®¿¡ (SAS2308) ¿¬°áÇÑ °Í¿¡¼µµ ·¹ÀÌµå º¼·ý ±¸¼ºÇϸé SMART°¡ ³ª¿ÀÁö ¾Ê°Åµç¿ä ...
H710P À¸·Î ¹Ù²Ù¸é ·¹ÀÌµå º¼·ý¿¡¼µµ SMART°¡ ³ª¿Ã±î¿ä???
LSI 9217 ÀÌ HBAÀ¸·Î Çì³î¿¡¼µµ »ç¿ëµÇ°í SMART Á¤º¸°¡ ³ª¿À±æ·¡ H710P ´ë½Å »ç¿ëÇÑ °Í Àε¥ ...
LSI HBA°¡ ½Ç¸Á ½ÃÅ°³×¿ä ....
¹ú½á ¹ã»õ°í ¾Æħ À̳׿ä...
¾Æħ ½Ä»çÇÏ°í H710P·Î ¹Ù²ã¼ ÇغÁ¾ß °Ú¾î¿ä.....
Çϵåµð½ºÅ© ¼¾Æ¼³ÎÀÌ ±×³ª¸¶ ¾Æ¹« Ä«µå¿¡¼³ª Çϵå ÀνÄÀ» ÀßÇÏ°í ·¹ÀÌµå ¹ÀÎ °Íµéµµ ÇÏµå °³°³ÀÇ °ªµéÀ» ÀÐÀ»¼ö Àֱ⿡ Ãßõ µå·Á º» °ÍÀÔ´Ï´Ù..
HBAÀ̵ç ij½¬ ´Þ¸° RAID CARDµç °ü°è´Â ¾ø´Ù¶ó°í »ý°¢ÇÕ´Ï´Ù..
Çϵåµð½ºÅ© ¼¾Æ¼³Î Àº À©µµ¿ì s/w ¿¡¼´Â È®ÀÎ Çغ¼²²¿ä
¸®´ª½º ¹öÀüÀº ÇãÁ¢ÇØ¿ä.
´ç¿¬ÇÏ°Ô ·¹ÀÌµå º¼·ý smart ³ª¿ÀÁö ¾Ê´Â °ÍÀº
È®ÀÎ Çß´ø »çÇ× ÀÔ´Ï´Ù
12Gb/s 3008Àº sas3ircu ÀÔ´Ï´Ù
2108,2208°°Àº ij½Ã¸Þ¸ð¸®°¡ÀÖ´Â°Ç megacli ³ª storcli¸¦ ½á¾ß Á¤º¸°¡ º¸ÀÔ´Ï´Ù
ÀÎÅÚº¸µå´Â ERST³ª RSTe±¸¼ºÀ̵Ǹç ERST·Î ·¹À̵屸¼ºÇϸé lsi¿¡¼ ¼ÒÇÁÆ®¿þ¾î ¶óÀ̼¾½º ÇüÅ·Πº¸µå¿¡ ³Ö¾îµÐ ·¹À̵å·Î ±¸¼ºµË´Ï´Ù ÀÌ°æ¿ì´Â megacli¿¡¼ º¸ÀÔ´Ï´Ù
lsi.com¿¡¼ sas2ircu ¹Þ¾Æ¼ ¼³Ä¡ÇÏ¸é µð½ºÅ©Á¤º¸°¡ º¸Àϲ®´Ï´Ù
sas2ircu ¿¡ º¸ÀÌ´Â µð½ºÅ© Á¤º¸´Â ÇÑÁ¤ÀûÀÏ ¼öÀÖ°í ij½ÃÀÖ´Â ·¹À̵å Ä«µåÀÇ °æ¿ì µð½ºÅ© ¿¡·¯Ä«¿îÆ®±îÁö Ç¥½ÃÇÕ´Ï´Ù
Àú´Â megacli ·Î µð½ºÅ© ¸ð´ÏÅ͸µÀ» ÇÕ´Ï´Ù
http://www.sproc.co.kr
Á¦°¡ »ç¿ëÇÏ´Â °ÍÀº LSI9217 (SAS2308_2) ÀÔ´Ï´Ù.
megacli ¹®¼¿¡¼´Â ¾Æ·¡¿Í °°ÀÌ ³ª¿À¹Ç·Î LSI9217 / LSI9207 Àº Áö¿ø ÇÏÁö ¾Ê´Â °ÍÀÌÁÒ ?
The StorCLI tool is designed to work with the MegaRAID product line. The StorCLI tool supports the following MegaRAID products.
1550; The 926x product line.
1550; The 928x product line.
1550; The 924x product line.
1550; LSI¢ç MegaRAID SAS iMR
1550; LSI MegaRAID SAS 9280-8e
1550; LSI MegaRAID SAS 9260CV-8i
1550; LSI MegaRAID SAS 9266CV-8i
1550; LSI MegaRAID SAS 9285-8e
[root@lnx2020 hba]# ./sas2ircu -help
LSI Corporation SAS2 IR Configuration Utility.
Version 20.00.00.00 (2014.09.18)
Copyright (c) 2008-2014 LSI Corporation. All rights reserved.
SAS2IRCU: Invalid command specified.
sas2ircu <controller #> <command> <parameters> ...
where <controller #> is:
Number between 0 and 255
where <command> is:
DISPLAY - display controller, volume and physical device info
LIST - Lists all available LSI adapters (does not need ctlr #>
CREATE - create an IR volume
DELETE - Delete entire RAID configuration on the selected controller
DELETEVOLUME - Delete a specific RAID Volume on the selected controller
HOTSPARE - make drive a hot spare
STATUS - display current volume status info
SETOFFLINE - set the physical disk to OFFLINE state
SETONLINE - set the physical disk to ONLINE state
CONSTCHK - Start Consistency Check operation on the specified IR Volume
ACTIVATE - Activate an Inactive IR volume
LOCATE - Locate a disk drive on an enclosure
LOGIR - Upload or Clear IR Log data
BOOTIR - Select an IR Boot Volume as primary boot device
BOOTENCL - Select an Enclosure/Bay as primary boot device
ALTBOOTIR - Select an IR Boot Volume as alternate boot device
ALTBOOTENCL - Select an Enclosure/Bay as alternate boot device
HELP - Display help information
where <parameters> are:
Command specific values; enter "sas2ircu <controller #> <command>"
to get command specific help
controller ¾øÀÌ ¼öÇà °¡´É ¸í·ÉÀº ¾Æ·¡ÀÇ sas2ircu LIST »Ó ÀÔ´Ï´Ù.
¾Æ·¡ ³»¿ëÁß controller ¹øÈ£°¡ ¹º°¡¿ä? Ȥ½Ã Index Àΰ¡¿ä?
sas2ircu ·Î SMART Á¤º¸¸¦ È®ÀÎ ÇÏ·Á¸é ¾î¶² ¿É¼ÇÀÌ ÇØ´ç ÇÏ´Â °ÍÀΰ¡¿ä?
# ./sas2ircu LIST
LSI Corporation SAS2 IR Configuration Utility.
Version 20.00.00.00 (2014.09.18)
Copyright (c) 2008-2014 LSI Corporation. All rights reserved.
Adapter Vendor Device SubSys SubSys
Index Type ID ID Pci Address Ven ID Dev ID
----- ------------ ------ ------ ----------------- ------ ------
0 SAS2308_2 1000h 87h 00h:03h:00h:00h 1000h 3060h
SAS2IRCU: Utility Completed Successfully.
Index ¸¦ controller ¹øÈ£·Î ÁöÁ¤ÇÏ´Ï STATUS°¡ ³ª¿À±â´Â Çϴµ¥¿ä... SMART´Â ¾Æ´Ï±º¿ä.
µð½ºÅ© ¿¡·¯Ä«¿îÆ®¸¦ À§ÇÑ sas2ircu ¿É¼ÇÀÌ ¹»±î¿ä??
# ./sas2ircu 0 STATUS
LSI Corporation SAS2 IR Configuration Utility.
Version 20.00.00.00 (2014.09.18)
Copyright (c) 2008-2014 LSI Corporation. All rights reserved.
Background command progress status for controller 0...
IR Volume 1
Volume ID : 286
Current operation : None
Volume status : Enabled
Volume state : Optimal
Volume wwid : 047380928b8c8cac
Physical disk I/Os : Not quiesced
SAS2IRCU: Command STATUS Completed Successfully.
SAS2IRCU: Utility Completed Successfully.
sas2ircu - 2008, 2308
sas3ircu - 3008
megacli, storcli - 2108, 2308, 3108
À§Ã³·³Áö¿øÇÏ°í ¿Âº¸µå »çŸÀÇ ÀÎÅÚ·¹À̵å´Â ERSTÀÇ °æ¿ì megasr µå¶óÀ̹ö·Î ÀâÈ÷°í megacli°¡ µË´Ï´Ù
ÀÏ´Ü ¿©±â±îÁöÀÌ°í megaraid ´Â µð½ºÅ© ¿¡·¯Ä«¿îÆ® Ç׸ñÀÌ ÀÖ¾î¼ µð½ºÅ© ºÒ·®À» ¾î´ÀÁ¤µµ ¿¹ÃøÇÒ¼öÀÖÁö¸¸ sas2ircu´Â ·¹À̵屸¼º½Ã µð½ºÅ© »óÅÂÁ¤µµ¸¸ È®ÀÎÇÒ ¼öÀÖ½À´Ï´Ù
ÄÁÆ®·Ñ·¯¿¡ ºñÇÁÀ½ ºÎÀú°¡¾ø¾î sgpio led ³ª sas2ircu¹Û¿£ Àå¾Ö¸¦ È®ÀÎÇÒ ¹æ¹ý¹Û¿£ ¾ø½À´Ï´Ù
sas2ircu 0 display ¿¡¼ ³ª¿À´Â Á¤º¸°¡ ÃÖ¼±ÀÔ´Ï´Ù
sas2ircu - 2008, 2308
sas3ircu - 3008
megacli, storcli - 2108, 2308, 3108 --> 2308 ÀÌ Æ÷ÇԵǴ °ÍÀÌ ¸Â½À´Ï±î?
"2108,2208°°Àº ij½Ã¸Þ¸ð¸®°¡ÀÖ´Â°Ç megacli ³ª storcli¸¦ ½á¾ß Á¤º¸°¡ º¸ÀÔ´Ï´Ù " ¿Í »óÃæµË´Ï´Ù. 2308 Àº ij½Ã¸Þ¸ð¸®°¡ ¾ø´Âµ¥¿ä.
StorCLI Reference :
The StorCLI tool is designed to work with the MegaRAID product line.
The StorCLI tool supports the following MegaRAID products.
1550; The 926x product line.
1550; The 928x product line.
1550; The 924x product line.
1550; LSI¢ç MegaRAID SAS iMR
1550; LSI MegaRAID SAS 9280-8e
1550; LSI MegaRAID SAS 9260CV-8i
1550; LSI MegaRAID SAS 9266CV-8i
1550; LSI MegaRAID SAS 9285-8e
ÀÌ ºÎºÐ¿¡¼ ÀÌÇØ°¡ Àß ¾ÊµÇ´Â ºÎºÐ ÀÔ´Ï´Ù.
LSI920x/921x series ´Â SAS 2008 Àä.
´ÔÀÇ ¼³¸íÀ¸·Î´Â sas2ircu - 2008, 2308 ÀÌ °¡´ÉÇÏ´Ù°í ÀÌÇصǰí
StorCLI Reference ¿¡¼´Â StorCLI Áö¿ø µÈ´Ù°í ³ª¿É´Ï´Ù.
Ȥ½Ã LSI Ĩ¼Â SAS¹øÈ£¿¡ µû¶ó¼ Áö¿ø ¹üÀ§°¡ ´Ù¸¥°Ô ¾Æ´Ï°í Á¦Ç°¹øÈ£ ´Ù¸¥°Ô ¾Æ´Ñ°¡ ? ¶ó°í »ý°¢ÀÌ µì´Ï´Ù.
¹¹°¡ ¸Â´Â °É±î¿ä ... Çϳª¾¿ ´ÙÇغ¸°í ±¸ÀÔÇÒ ¼ö´Â ¾ø´Âµ¥ ¤¾¤¾¤¾
2308ÀÌ ¾Æ´Ï¶ó 2208ÀÔ´Ï´Ù Á¦°¡ ¿ÀŸ¸¦ ³»¾ú½À´Ï´Ù
È¥¼±À» µå·Á Á˼ÛÇÕ´Ï´Ù
µÚ´Ê°Ô ºÃ½À´Ï´Ù.
½Ã½ºÅÛ IP address¸¦ µî·ÏÇϸé À¥À¸·Î ½Ã½ºÅÛµéÀÇ »óÅ üũ°¡ µÇ´Â °ÍÀ̱º¿ä.
ÀÌ·± ÀÛ¾÷Àº »ó¿ëÅøÀ» Àΰ¡¿ä?
ÆäÀÌÁö ³»¿ëÁß °³¹ßÁß À̶ó°í ³ª¿À´Â °ÍÀº ´Ô²²¼ À¥ ÆäÀÌÁö »ý¼º ÀÛ¾÷ ÁøÇàÀ» À̶ó´Â ÀÇ¹Ì Àΰ¡¿ä?
ÀÌ ÀÛ¾÷ °á°ú¹°Àº ÆǸŸ¦ ÇϽô °Í Àΰ¡¿ä?
º¸½Å ÆäÀÌÁö´Â megacli¹× storcli, ±âŸ ½ºÅ©¸³Æ®·Î Á÷Á¢ ¸¸µé°íÀÖ´Â »çÀÌÆ® ÀÔ´Ï´Ù
¿¹Àü¿¡ ¸¸µé¾î¼ »ç¿ëÇÏ´ø http://oasis.sproc.co.kr ÀÇ °³¼± ¹öÀü Á¤µµ·Î ½Ã°£µÉ¶§¸¶´Ù Á¶±Ý¾¿ ¸¸µé¾î º¸°íÀÖ½À´Ï´Ù. ¼øÀüÈ÷ Ãë¹Ì»ýÈ°ÀÔ´Ï´Ù
https://hwraid.le-vert.net/wiki/LSIFusionMPTSAS2
sudo modprobe sg
sudo tee -a /etc/modules > /dev/null << EOT
sg
EOT
sudo smartctl -a /dev/sg1
sudo smartctl -a /dev/sg2
sudo smartctl -a /dev/sg3