S.M.A.R.T 帳ϴ.

Noname1   
   ȸ 1383   õ 0    

Ȣ16;드디스크 1221;보 보lj16;데 리눅스라 시각1201;1004;/196; 위험한 상태1064;1648; 1096; 모르,192;lj16;데 무시해도 .104;lj16; 상태1068;까요?
1473;요 문서와 과,144; 사1652; 보관Ȣ16;lj16; 디스크/196; 사용Ȣ16;고 1080;습니다.

다른 Ȣ16;드디스크에 비해 온도가 착Ȣ16;네요.


smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.35
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Laptop HDD
Device Model:     ST500LT012-9WS142
Serial Number:    @@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@
LU WWN Device Id: 5 000c50 072d31e12
Firmware Version: 0001SDM1
User Capacity:    500,107,862,016 bytes [500 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    5400 rpm
Form Factor:      2.5 inches
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Tue Jul  5 19:29:51 2022 JST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  99) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x1035) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   115   099   006    Pre-fail  Always       -       96041416
  3 Spin_Up_Time            0x0003   099   099   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   098   098   020    Old_age   Always       -       2353
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   070   057   030    Pre-fail  Always       -       34446217138
  9 Power_On_Hours          0x0032   086   086   000    Old_age   Always       -       12272 (175 161 0)
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   099   099   020    Old_age   Always       -       1531
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       -       2
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   065   050   045    Old_age   Always       -       35 (Min/Max 25/37)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       -       371
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       39
193 Load_Cycle_Count        0x0032   007   007   000    Old_age   Always       -       187974
194 Temperature_Celsius     0x0022   035   050   000    Old_age   Always       -       35 (0 9 0 0 0)
196 Reallocated_Event_Count 0x000f   087   087   030    Pre-fail  Always       -       11602 (18033 0)
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
240 Head_Flying_Hours       0x0000   091   091   000    Old_age   Offline      -       11602 (70 113 0)
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      -       174324638
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      -       341861552
254 Free_Fall_Sensor        0x0032   100   100   000    Old_age   Always       -       0

SMART Error Log Version: 1
ATA Error Count: 2
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 2 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  08 51 00 00 00 00 00  Error:

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  3f 00 01 ff ff ff 4f 00      00:00:14.283  WRITE LOG EXT
  2f 00 02 ff ff ff 4f 00      00:00:14.283  READ LOG EXT
  3f 00 01 ff ff ff 4f 00      00:00:14.283  WRITE LOG EXT
  2f 00 02 ff ff ff 4f 00      00:00:14.283  READ LOG EXT
  3f 00 01 ff ff ff 4f 00      00:00:14.283  WRITE LOG EXT

Error 1 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  08 51 00 00 00 00 00  Error:

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  3f 00 01 ff ff ff 4f 00      00:00:14.237  WRITE LOG EXT
  2f 00 02 ff ff ff 4f 00      00:00:14.237  READ LOG EXT
  3f 00 01 ff ff ff 4f 00      00:00:14.237  WRITE LOG EXT
  2f 00 02 ff ff ff 4f 00      00:00:14.237  READ LOG EXT
  3f 00 01 ff ff ff 4f 00      00:00:14.237  WRITE LOG EXT

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%     11888         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.


ª ϼ ϰ.
ҽ 2022-07
α׿ ǥð ̰ ũ ƴϰ ̽ ߻ Դϴ
ũ ߿ Ŀ ų ̺ ° ..

SMART overall-health self-assessment test result: PASSED
  PASS ũ ̵
ٴ ǹ Դϴ
ũ ٴ ̶ ٴ. 
Ʈ Ѱ ġ ʾҴ Դϴ

ǰ ̰ 0 ʾƿ
Ϳ ̼ ϰ
SMART ʱȭؼ Ʈ 0
     
Noname1 2022-07
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG    VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate    0x000f  115  099  006    Pre-fail  Always      -      96041416
  7 Seek_Error_Rate        0x000f  070  057  030    Pre-fail  Always      -      34446217138
ǥ ִ ʹ ʴµ Ű澵 ʿ ΰǰ?
          
ҽ 2022-07
ǽø Ͻʽÿ.
SMART Error ΰ  SMART overall ٰ 𵨹ȣ ߱.
ũ 500GB 2.5ġ Ͻ 󸶳 ǽ 𸣰 10 Դϴ.
eBay ̰  ã $10 Դϴ.
ڹ 2022-07
ϵ尡 Ǵ Ŭеũ Ͻ Դϴ..
˻


QnA
Page 341/438
2023-05   1401   ̴
2022-04   2229   ܽźƾ
07-10   627   Բδٱ
2023-05   1131  
2022-04   1229  
07-08   702   õǻ
2023-05   1600   ̸Ÿ2
2022-04   1454   ϵ
07-05   901  
2023-05   1446   choigo
2022-04   1269   g
07-04   625  
2023-05   1931   ġ갳
2022-04   1067   Ż
07-02   629  
2023-04   2088  
2022-04   1130   Psychophysi
06-30   684   ٷ
2023-04   1006   츶ũ
2022-04   1410   Initu2