·¹À̵åÄ«µå ¹èÅ͸® »óÅ Á» ºÁÁÖ¼¼¿ä
scn331 12-17 2024-12-17 20:15:53 Á¶È¸ 355 Ãßõ 0
changing WB logical drives to WT, Forced WB VDs are not affected
로그에 경고로 위에 문구가 뜨더니 1주정도 놔뒀더니 사라지긴했는데
배터리를 바꿔야하나요?
changing WB logical drives to WT, Forced WB VDs are not affected => ÀÌ ¿µ¾îÀÇ Àǹ̴ ¾Æ½Ã³ª¿ä??
º£Å͸®´Â ÃæÀüÁßÀÌ°í º£Å͸®°¡ ¿ªÇÒÀ» ¸øÇÏ°í ÀÖÀ¸´Ï, ·¹À̵å ÄÁÆ®·Ñ·¯ÀÇ º¼·ý¿¡ ¹èÄ¡µÇ¾î ÀÖ´Â
CacheÀÇ ¹æ½ÄÀ» Write-Back ¿¡¼ Write-Through ·Î ¹Ù²å½À´Ï´Ù. ¿Ö³ÄÇϸé CacheÀÇ Àü¿øÀ» ´ëºñ Çß´ø
º£Å͸®°¡ ¾ø¾î¼(ÃæÀüÁß)¿©¼¿ä.. ´Ù½Ã °Á¦ÀûÀ¸·Î Write-Back À¸·Î º¯°æÇÏ¿©µµ Àû¿ëµÇÁö ¾Ê½À´Ï´Ù.
Cache ¹æ½Ä
Write-Back : µ¥ÀÌÅ͸¦ Cache°¡ ¸ÕÀú ¹Þ¾ÆÁÖ°í ´ëÀÀÀ» ÇÏ´Ï ¼º´ÉÀÌ ÁÁ½À´Ï´Ù. Cache¿¡ µ¥ÀÌÅÍ°¡ ³²¾Æ Àֱ⿡ ±ÞÀÛ Á¤Àü½Ã¿¡ µ¥ÀÌÅÍ°¡ Cache¿¡ ³²¾Æ ÀÖ°Ô µË´Ï´Ù.
: ¸¶Áö¸· Æ®·»Á§¼Ç µ¥ÀÌÅÍ°¡ Cache¿¡ ³²¾Æ ¹ö¸®°Ô µË´Ï´Ù. º£Å͸®·Î º¸È£µÇ°í´Â ÀÖÁö¸¸. DiskµéÀº ¸ØÃá »óÅÂ¶ó »¡¸® Àü±â°¡ µé¾î ¿Í¾ß ÇÕ´Ï´Ù.
Write-Through : Cache¸¦ »ç¿ëÇÏÁö ¾Ê°í Disk Volume¿¡ Data¸¦ Á÷Á¢ ¾¹´Ï´Ù. ¼Óµµ´Â Á¶±Ý óÁöÁö¸¸ µ¥ÀÌÅ͸¦ Á÷Á¢ ¾²±â¿¡ Á¤Àü¿¡ ´ëÇÑ ¾ÈÁ¤¼ºÀº Á»´õ ³ô½À´Ï´Ù.