안녕Ȣ16;세요160;
1228;가 무Ꮗ1;1012; 놓치고 1080;lj16;,163;1064;1648;... 고수님들 도움1328; ǥ12;ᓠ1;드립니다.
왜 32GB 12개 1064;식1060; .104;었lj16;데 메모리lj16; 352GB만 사용할까요? 12636;.12636;
메모리 안올라올ǐ16; 1221;말 심1201;1004;/196; 7192;드네요160;
뺏다 꽂았다.. 손가락도 아프구요 12636;12636;..
idrac 보다보니160;
1068;0152; 광 NIC와 FC Ǻ12;ᇨ1;터가 따/196; ǥ16;리.104;Ǻ12;1080;lj16;,152; 확1064;했lj16;데 1060;,148; 뭔가 1328; 더 특별한,152;까요?
FClj16; TCP통신 안.104;고 SCSI만 .108;다lj16;,163; 같1008;데.. 1064;피니티 케1060;블 같1008;,152;까요? (한번도 안써봐서 모릅니다 ^^;;)
1648;빅1060; 16GB 라고 표기.104;Ǻ12; 1080;Nj12;데.. 1060;런 1648;빅1008; 1068;0152; LC 광케1060;블 꽂아1452;면 .104;lj16;,148;1648; ..160;
ǥ12;품 뒤1648;다가 0156;견해서 한번 꽂아봤lj16;데 케1060;블 문에 아1649; 써보기 1204; 1077;니다만160;
케1060;블 뭐 사야Ȣ16;lj16;1648; 몰라 한번 여쭤봅니다..
memtest86 pro¿¡¼ ¸Þ¸ð¸® Å×½ºÆ®ÈÄ ¾î¶² ¸Þ¸ð¸® ¸ðµâÀÇ ¾îµð°¡ ¹®Á¦ÀÎÁö±îÁö ¸®Æ÷Æ®°¡ ³ª¿É´Ï´Ù..
¸Þ¸ð¸® ¸ðµâ ÀνĵǴ ¸ðµ¨°ú ÀÎ½Ä ¾ÈµÇ´Â ¸ðµ¨ ¸ðµ¨¸í ½ºÆ¼Ä¿ ³ª¿À°Ô »çÁø ºÎŹµå¸³´Ï´Ù..
±×¸®°í ¼¹ö ¸ðµ¨¸íµµ¿ä..
¸ðµÎ °°Àº ¸ðµ¨ÀÌ°í »ï¼º 32G 2R ¸ðµ¨ÀÔ´Ï´Ù.
»çÁø¿¡ º¸½Ã¸é ÀνÄÀº 12°³ ¸ðµÎ µÇ¾îÀÖ½À´Ï´Ù. ±×·±µ¥ ÃÑ ¸Þ¸ð¸® ¿ë·®ÀÌ ´Ù¸£°Ô ³ª¿À°í ÀÖ½À´Ï´Ù
¼¹ö´Â Dell R740XD ÀÔ´Ï´Ù.
¸Þ¸ð¸® À§Ä¡¸¦ È®ÀÎÇغ¸´Ï ù¹ø° CPU ü³Î 3/4/5 ³×¿ä..
¸î ¹ø °Þ¾î º¸¼ÌÀ» µíÇÕ´Ï´Ù¸¸
1: ù¹ø° CPU ¸Þ¸ð¸® ÄÜÆ®·Ñ·¯ /CPU¼ÒÄÏ ºÒ·®
2: ¸¶´õº¸µåÀÇ ¸Þ¸ð¸® ¼ÒÄÏ¿¡¼ CPU »çÀÌÀÇ PCB ¶óÀÎÆÄ¼Õ ( PCB ÆäÅÏ ÆļÕ)
3: ¸Þ¸ð¸® ¸ðµâ ¼ÒÄÏ ºÒ·® (ÀÌ°ÍÀº È®·üÀÌ Á» ³ôÁö ¾Ê½À´Ï´Ù..)
4 : ¸Þ¸ð¸® Àü¿øºÎ ºÒ·®
°°Àº °ÍÀ» ÀǽÉÇϽðí Á¡°ËÇغ¸½Ã±â ¹Ù¶ø´Ï´Ù..
´ñ±Û¿¡µµ ´Þ·Á ÀÖÁö¸¸ BMC(iDRAC) ÀÇ ¼ÒÇÁÆ®¿þ¾î ÀÎ½Ä ¹®Á¦ÀÏ ¼öµµ ÀÖ½À´Ï´Ù..
Áöºòµµ ¼·Î ȣȯÀÌ ¾ÈµÇ´Â°Ô ¸Â´Âµ¥, ¸·»ó ³¢¿öº¸¸é ¶Ç µ¿ÀÛÇÏ´Â °æ¿ìµµ ÀÖÁö¸¸....
¹°¸®ÀûÀÎ Àü¼Û¹æ½ÄÀº °°±â ¶§¹®¿¡ ±¤ÄÉÀ̺íÀº µ¿ÀÏÇÕ´Ï´Ù.
¸»¾¸ÇϽŠ16G ÁöºòÀº LC Ä¿ÅØÅÍ ÇüÅÂÀÇ ±¤ÄÉÀÌºí »ç¿ëÇÕ´Ï´Ù.
±¤¸ðµâ°ú ÄÉÀ̺íÀº Àü¿ëÀ̶ó°í º¸½Ã¸é µË´Ï´Ù..
FCÄ«µå´Â ±¤¸ðµâµµ º¸Åë °°ÀÌ ²ÅÇô¼ ÆÇ¸ÅµÉ ÅÙµ¥¿ä??
https://www.ebay.com/itm/283868157005
QLE2692-Dell QLOGIC Dual Port Fibre Channel 16Gb PCIe HBA 0YCVFG 0WVT0T 0CK9H1
https://kr.genuinemodules.com/qlogic?sort=rating&order=ASC
FC ÄÉÀÌºí¿¡ ´ëÇÑ ½ºÆÑÀ̳ª Á¦Á¶»ç °°Àº °ÍÀº Àú´Â ¸ð¸¨´Ï´Ù..
Data rate
The Qlogic 16G FC SFP+ Transceiver has a data rate of 16 Gbps.
The Qlogic 16G FC FibreChannel SR 850nm SFP+ Transceiver has a data transfer rate of 850nm.
The QLogic 16Gb FC Single-port and Dual-port HBAs have a data rate of 14.025 Gbps (1600 MBps), 8.5 Gbps (800 MBps), and 4.25 Gbps (400 MBps).
Maximum reach
The Qlogic 16G FC SFP+ Transceiver has a maximum reach of 100m.
The JSH-14SWAA1-QL QLogic 16G SFP+ FC Short Range Transceiver has a maximum reach of 300m.
Media
The Qlogic 16G FC SFP+ Transceiver uses Multi Mode Fibre (MMF).
The QLogic Enhanced Gen 5 16 Gb Fibre Channel HBAs use OM1, OM2, OM3, and OM4 MMF.
Connector type
The Qlogic 16G FC SFP+ Transceiver uses Fibre LC Duplex.
The JSH-14SWAA1-QL QLogic 16G SFP+ FC Short Range Transceiver uses LC Duplex.
Wavelength
The FTLF8529P4BCV-QM Qlogic Compatible 16G SFP+ Transceiver has a Tx/Rx Wavelength of 850 nm.
The Qlogic 16G FC FibreChannel SR 850nm SFP+ Transceiver has an 850nm
±¸±Û AI¿¡¼ ³ª¿Â ÀÚ·áÀÔ´Ï´Ù..
¸ÖƼ¸ðµåÀÎÁö ½Ì±Û¸ðµåÀÎÁö°¡ °³ÀÎÀûÀ¸·Î ±Ã±ÝÇߴµ¥ ¸ÖƼ¸ðµå³×¿ä..
10G ·£¿ë ±¤ÄÉÀ̺í(LC-LC ¸ÖƼ¸ðµå , OM4 ±Þ ÀÌ»ó ???) ·Î ¿ì¼± ½ÃµµÇغ¸¼¼¿ä..
FC HBA Ä«µå¸¦ ÅëÇؼ ½ºÅ丮Áö¿¡ DISK¸¦ ÇÒ´ç ¹ÞÀ¸¸é ¸¶Ä¡ ³»ºÎ¿¡ DISK¸¦ ºÙÀÎ °Í ó·³ º¸ÀÌ°Ô µË´Ï´Ù.
16Gbps ¼Óµµ·Î µ¿ÀÛÇÕ´Ï´Ù.
½ÇÁúÀûÀ¸·Î TCP Åë½Åº¸´Ù µ¿ÀÛ ¹æ½ÄÀÌ ´õ ºü¸£°Ú³×¿ä.
°¨»çÇÕ´Ï´Ù!