[ETC] Quantum LTO6 µå¶óÀ̺ê Diagnostics °á°ú

   Á¶È¸ 6378   Ãßõ 0    

 

xTalk Version 6.7.0.0

____________________________________________________________

Start: 05/20/2018 15:21:58
Device: QUANTUM ULTRIUM-HH6 10WT087802 0:3:0

Device_Health_Check_LTOC
____________________________________________________________

Ready Test
No Problem Detected
____________________________________________________________

Record Drive Settings
Current Compression Status = Enabled
No Problem Detected
____________________________________________________________

Drive Detection Test
Drive Type:Ultrium 6-HH
No Problem Detected
____________________________________________________________

SCSI Interconnect Test
Write/Read Pass @ 10 of 100
Write/Read Pass @ 20 of 100
Write/Read Pass @ 30 of 100
Write/Read Pass @ 40 of 100
Write/Read Pass @ 50 of 100
Write/Read Pass @ 60 of 100
Write/Read Pass @ 70 of 100
Write/Read Pass @ 80 of 100
Write/Read Pass @ 90 of 100
Write/Read Pass @ 100 of 100
No Problem Detected
____________________________________________________________

Drive Information Report
Drive Type R12;R12;R12;R12;R12;- : Ultrium 6-HH
Drive Serial Number R12;R12;- : 10WT087802
Media Changer Present R12;R11; : No
Vendor ID R12;R12;R12;R12;R12;- : QUANTUM
Product ID R12;R12;R12;R12;R12;- : ULTRIUM-HH6
Product Revision Level R12;- : E4J1
Product Family R12;R12;R12;R12; : 2.5 / 6.25 TB
Servo FW Revision R12;R12;R12; : N/A
Power On Hours R12;R12;R12;R12; : 171
Tape Motion Hours R12;R12;R12; : 2
Load Count R12;R12;R12;R12;R12;- : 27
Cleaning Tape Count R12;R12;- : 0
Last Clean R12;R12;R12;R12;R12;- : 2

Time Error Error Description
=======================================
0 Hours 00/00/00 “No additional sense information Other sense data fields indicate the reason for command failure.̶1;
0 Hours 00/00/00 “No additional sense information Other sense data fields indicate the reason for command failure.̶1;
0 Hours 00/00/00 “No additional sense information Other sense data fields indicate the reason for command failure.̶1;
0 Hours 00/00/00 “No additional sense information Other sense data fields indicate the reason for command failure.̶1;
0 Hours 00/00/00 “No additional sense information Other sense data fields indicate the reason for command failure.̶1;
Report Complete
____________________________________________________________

Quick Write Read Test
Setting compression on
Setting variable block mode
Rewinding
Write 2 4k blocks with random data and 2 filemarks…
Write 2 file marks
Rewinding
Read 1st block
Read 2nd block
Read 1st file mark
Read 2nd file mark
Rewinding
No Problem Detected
____________________________________________________________

Small Buffer Write Read Test
Setting the compression on
Setting to variable block mode
Rewinding
Write 1 32k block of FFs…
Rewinding
Read compare 1 32k block…
No Problem Detected
____________________________________________________________

System Level Test
Setting fixed block mode
Setting the compression off
Rewinding
Write 100 blocks with compression off
Rewinding
Read compare 100 blocks
Rewinding
Setting the compression on
Write 100 blocks with compression on
Rewinding
Read compare 100 blocks
Rewinding
No Problem Detected
____________________________________________________________

Timed Performance Test
Setting the compression off
Setting the block size : 32K
Rewinding
Starting the clock
Stopping the clock
Data Transfer Time: 0:0:10.489
Test Time: 0:0:10.490
Rewinding
No Problem Detected
____________________________________________________________

Pattern Test
Setting to fixed block mode
Setting the compression on
Rewinding
Writing Pattern #1
Rewinding
Reading Pattern #1
Rewinding
Writing Pattern #2
Rewinding
Reading Pattern #2
Rewinding
Writing Pattern #3
Rewinding
Reading Pattern #3
Rewinding
Writing Pattern #4
Rewinding
Reading Pattern #4
Rewinding
Writing Pattern #5
Rewinding
Reading Pattern #5
Rewinding
Writing Pattern #6
Rewinding
Reading Pattern #6
Rewinding
No Problem Detected
____________________________________________________________

LTO Write Read Error Rate Test
Determining the drive type…
Ultrium 6 detected

Fetching the drive serial number…
SN: 10WT087802

Loading Tape…

Determining the tape type…
Ultrium 6 tape detected

Rewinding…

Starting test…
No Problem Detected
____________________________________________________________

Restore Drive Settings
____________________________________________________________

Test Summary
Drive Detection Test R12;R12;R11; : Passed
SCSI Interconnect Test R12;R12; : Passed
Tape Load Test R12;R12;R12;R12;R11; : Passed
Quick Write/Read Test R12;R12;- : Passed
Small Buffer Wr/Rd Test R12;R11; : Passed
System Level Test R12;R12;R12;R11; : Passed
Time Test R12;R12;R12;R12;R12;R12;- : Passed
Multi-Pattern Test R12;R12;R12;- : Passed
LTO Error Rate Test R12;R12;R11; : Passed
No Problem Detected

____________________________________________________________

Finish: 05/20/2018 15:43:51
Elapsed Time: 00:21:53.25


테1060;프 /196;드 한번1008; 1228;가 한 ,144;니.. ,144;1032; 새,163;1060;군요.

ªÀº±Û Àϼö·Ï ½ÅÁßÇÏ°Ô.
dongcheol 2018-05
TAPEµå¶óÀ̺ê 10³â ÀüºÎÅÍ~ Áö¼ÓÀûÀ¸·Î °ü½ÉÀº Àִµ¥...  Çϵåµð½ºÅ©ÀÇ ¹ßÀüÀÌ ³Ê¹«»¡¸® ±×³É ÀÚ¸®¸¸ Â÷ÁöÇÏ´ÂÁßÀε¥ ÀߺýÀ´Ï´Ù.
     
¼ÛÁÖȯ 2018-05
Å×ÀÌÇÁµµ Çϵåµð½ºÅ©¸¸Å­ ¹ßÀüÀÌ ºü¸£ÁÒ. ÇÏÇÏ
ÇöÀç ÃֽŠ±Ô°ÝÀÎ LTO-8Àº Ä«Æ®¸®Áö´ç ºñ¾ÐÃà 12TBÀÇ ¿ë·®À» °¡Áö´Ï..
          
dongcheol 2018-05
¾È±×·¡µµ ÃÖ±Ù LTO-7 º¸°íµµ ±ô¦ ³î¶ú½À´Ï´Ù~ °¡°Ý´ëºñ ÀúÀå¿ë·®Àº ¿ª½Ã~~ ÈÄ´ú´ú~~~ À̹ø¿¡ ½Ã°ñ º»°¡ ³»·Á°¡¸é~ Å×ÀÌÇÁ µå¶óÀ̺êµé ´ÙÇѹø ²¨³» ºÁ¾ß °Ù³×¿ä  ±×¸¹Àº Å×ÀÌÇÁ¿¡ ¹¹°¡ µé¾îÀÖ³ª... ±â¾ïµµ ¾È³ª´Âµ¥ ¸»ÀÌÁÒ^^;;~


Á¦¸ñPage 36/254
2018-10   6193   ¸¼ÀººÎö
2018-10   8062   Å丶ÅäÅ·
2018-10   6749   ¼ÛÁÖȯ
2018-10   8681   twopaik
2018-10   8347   susemi
2018-10   6108   ±è°­È£
2018-10   5873   ÁÖ´¨s
2018-10   5204   ±è°Ç¿ì
2018-09   4909   À̼±±Ô
2018-09   5883   ¹Ú¹®Çü
2018-09   5396   ¹Ú¹®Çü
2018-09   5978   ¹Ú¹®Çü
2018-09   7070   ¾Æ±¸¸£¸£
2018-09   6415   ±è°Ç¿ì
2018-09   6458   ȲȥÀ»ÇâÇØ
2018-09   6553   ¾Æ±¸¸£¸£
2018-09   5707   À̼±±Ô
2018-09   4368   À̼±±Ô
2018-09   5991   À̼±±Ô
2018-09   12812   À̼±±Ô